Detailed investigation of transmission and emission data smoothing protocols and their effects on emission images

被引:32
作者
Chatziioannou, A
Dahlbom, M
机构
[1] IEEE, Los Angeles
[2] Department of Molecular and Medical Pharmacology, Division of Nuclear Medicine, UCLA School of Medicine, Los Angeles
基金
美国国家卫生研究院;
关键词
D O I
10.1109/23.485968
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Measured attenuation correction in PET is routinely performed using transmission scans, Acquisition time and noise considerations necessitate low-pass filtering of the transmission data before generating the attenuation correction matrix, This smoothing operation reduces noise propagation from transmission into emission data but also introduces image artifacts that are mostly pronounced around areas of strongly varying attenuation coefficients, The source of these artifacts, which lies in the mismatch of the spatial resolutions of emission and transmission data, was investigated in this study, The effect of different transmission and emission sinogram smoothing protocols on the emission images was also investigated, A method is proposed that addresses the problem, in conjunction with the filtering step during reconstruction. Instead of the standard in-plane low-pass filtering of the emission data during reconstruction, emission and transmission sinograms can be volumetrically filtered to the desired image resolution prior to attenuation correction while reconstruction is performed with no smoothing (Ramp filter), This operation reduces or eliminates resolution mismatch and consequent image artifacts, especially in cardiac studies, The proposed method improves the accuracy of the activity distribution in emission images with minimal computational and signal-to-noise ratio (SNR) cost.
引用
收藏
页码:290 / 294
页数:5
相关论文
共 10 条
[1]   STUDY ON THE USE OF TRANSMISSION SCANS FOR WHOLE-BODY PET ATTENUATION CORRECTION [J].
CHATZIIOANNOU, A ;
DAHLBOM, M ;
HOH, CJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) :1545-1550
[2]   PROBLEMS IN SIGNAL-TO-NOISE RATIO FOR ATTENUATION CORRECTION IN HIGH-RESOLUTION PET [J].
DAHLBOM, M ;
HOFFMAN, EJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1987, 34 (01) :288-293
[3]  
DEGRADO TR, 1994, J NUCL MED, V35, P1398
[4]   AN INVESTIGATION OF SCATTER IN ATTENUATION CORRECTION FOR PET [J].
DIGBY, WM ;
HOFFMAN, EJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) :1038-1042
[5]  
HUANG SC, 1979, J COMPUT ASSIST TOMO, V3, P804
[6]  
HUANG SC, 1981, J NUCL MED, V22, P627
[7]  
MCCORD ME, 1992, J NUCL MED, V33, P1209
[8]  
MEIKLE SR, 1993, J NUCL MED, V34, P143
[9]   THE ECAT EXACT HR - PERFORMANCE OF A NEW HIGH-RESOLUTION POSITRON SCANNER [J].
WIENHARD, K ;
DAHLBOM, M ;
ERIKSSON, L ;
MICHEL, C ;
BRUCKBAUER, T ;
PIETRZYK, U ;
HEISS, WD .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1994, 18 (01) :110-118
[10]  
XU EZ, 1991, J NUCL MED, V32, P161