Computer-assisted total knee arthroplasty: Does the tibial component remain at malposition risk?

被引:5
作者
Bove, J. -C. [1 ]
机构
[1] Val de Sambre Multispecialties Private Hosp, F-59600 Maubeuge, France
关键词
Computer-assisted surgery; Total knee arthroplasty; NAVIGATION; REPLACEMENT; ALIGNMENT; PRECISION; ACCURACY; SURGERY;
D O I
10.1016/j.otsr.2009.11.017
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Objectives: The development of computer-assisted surgery in total knee arthroplasty continues its search for better accuracy in the spatial positioning of prosthetic components and in achieving the best ideal ligament balance. Many studies have underscored the value of computer-assisted navigation in obtaining precise bone cuts in terms of both orientation and location, which would optimize bone resection and thereby fulfill ligament balancing requirements. Yet improving bone cut accuracy can be undermined by positioning errors of the component at the final stage of implantation. The objective of this prospective study was to assess this possible loss of accuracy and to suggest possible solutions to minimize this risk. Material and methods: A consecutive series of 50 total knee arthroplasties was studied using an imageless computer navigation system. This study compared the spatial orientation of the prosthesis components determined using software (frontal positioning for the femoral component, frontal and sagittal positioning for the tibial component) with the recorded orientation of the corresponding bone cuts, which allowed us to quantify the loss of accuracy of these predefined positions after cutting. Trial and final implant orientation was taken into account. Moreover, the mechanical axes of the lower limb, the trial and then the final prosthesis in place were compared. Two procedures were abandoned in the study and two patient files were incomplete, which left a series of 46 cases (29 females and 17 males; mean age at surgery, 67 years; mean BMI, 31.27). Results: Bone cut orientation was consistently found to be satisfactory. Frontal orientation of the final femoral component (0.2 degrees valgus) did not differ statistically significantly from the distal femoral cut (0.3 degrees valgus) and from the orientation of the trial femoral component, as was true of the slope of the tibial component (4.8 degrees) versus the tibial cut (6.3 degrees) and the mechanical axis of the lower limb with the trial prosthesis and the final implant. The frontal plane orientation of the tibial component (0.6 degrees varus) differed statistically significantly from the bone cut (0.1 degrees valgus). Discussion: Several studies have demonstrated the value of computer-assisted surgery, notably in the accuracy of the bone cuts, confirming the work reported herein. The loss of accuracy observed between the bone cut and the final implantation can only be explained by soft tissues between the prosthesis and the bone cut, unequal cement thickness, an orientation error in the impaction handle when placing the final implant, or a conflict between the prosthetic keel and cortical bone. Better exposure of the tibial plateaus, discontinuation of cement use, and navigated impaction ancillary tools could reduce these errors. Level of evidence: Level IV. Prospective study. (C) 2010 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:536 / 542
页数:7
相关论文
共 21 条
[1]
Distal femur rotational alignment and patellar subluxation: A CT scan in vivo assessment [J].
Abadie, P. ;
Galaud, B. ;
Michaut, M. ;
Fallet, L. ;
Boisrenoult, P. ;
Beaufils, P. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2009, 95 (04) :267-271
[2]
Alignment in total knee arthroplasty -: A comparison of computer-assisted surgery with the conventional technique [J].
Bäthis, H ;
Perlick, L ;
Tingart, M ;
Lüring, C ;
Zurakowski, D ;
Grifka, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (05) :682-687
[3]
Computer-assisted total-knee arthroplasty.: Comparison of two successive systems.: Learning curve [J].
Bove, J. -C. .
REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2008, 94 (03) :252-260
[4]
Alignment deviation between bone resection and final implant positioning in computer-navigated total knee arthroplasty [J].
Catani, Fabio ;
Biasca, Nicola ;
Ensini, Andrea ;
Leardini, Alberto ;
Bianchi, Luca ;
Digennaro, Vitantonio ;
Giannini, Sandro .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (04) :765-771
[5]
Computer-assisted knee arthroplasty versus a conventional jig-based technique -: A randomised, prospective trial [J].
Chauhan, SK ;
Scott, RG ;
Breidahl, W ;
Beaver, RJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (03) :372-377
[6]
When computer-assisted knee replacement is the best alternative [J].
Fehring, Thomas K. ;
Mason, J. Bohannon ;
Moskal, Joseph ;
Pollock, David C. ;
Mann, John ;
Williams, Vincent J. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (452) :132-136
[7]
Computer-assisted navigation increases precision of component placement in total knee arthroplasty [J].
Haaker, RG ;
Stockheim, M ;
Kamp, M ;
Proff, G ;
Breitenfelder, J ;
Ottersbach, A .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (433) :152-159
[8]
Precision in orthopaedic computer navigation [J].
Hüfner T. ;
Kendoff D. ;
Citak M. ;
Geerling J. ;
Krettek C. .
Der Orthopäde, 2006, 35 (10) :1043-1055
[9]
CORONAL ALIGNMENT AFTER TOTAL KNEE REPLACEMENT [J].
JEFFERY, RS ;
MORRIS, RW ;
DENHAM, RA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (05) :709-714
[10]
Jenny Jean-Yves, 2004, Comput Aided Surg, V9, P161, DOI 10.3109/10929080500095517