Electropolymerized manganese porphyrin/polypyrrole films as catalytic surfaces for the oxidation of nitric oxide

被引:103
作者
Diab, N [1 ]
Schuhmann, W [1 ]
机构
[1] Ruhr Univ Bochum, Lehrstuhl Analyt Chem AG Elektroanalyt & Sensor, D-44780 Bochum, Germany
关键词
polypyrrole; manganese porphyrin; electropolymerization; pulse amperometry; nitric oxid; NO;
D O I
10.1016/S0013-4686(01)00565-5
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A porphyrin-based NO sensor has been prepared using Mn(II)-meso-tetracarboxyphenylporphyrin linked via a spacer chain to a pyrrole unit, By means of electrochemically induced formation of a porphyrin/polypyrrole film on the microelectrode a suitable catalytic surface for NO oxidation could be obtained. The modified electrode displays excellent electrocatalytic activity for the oxidation of NO at similar to 720 mV versus Ag/AgCl. A Nafion membrane coating was used as charge-selective layer in order to diminish interferences by negatively charged ions, especially NO2-. The response of the microsensor for NO-oxidation was monitored in phosphate buffer using differential pulse voltammetry and constant-potential amperometry. The detection limit in the latter case has been determined to be 1 x 10(-7) M NO. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:265 / 273
页数:9
相关论文
共 58 条
[21]  
GUILIANO R, 1972, FARMACO, V27, P908
[22]  
Habermüller K, 2000, ELECTROANAL, V12, P1383, DOI 10.1002/1521-4109(200011)12:17<1383::AID-ELAN1383>3.0.CO
[23]  
2-0
[24]   SPECTROSCOPIC AND ELECTROCHEMICAL RESPONSE TO NITROGEN MONOXIDE OF A CATIONIC IRON PORPHYRIN IMMOBILIZED IN NAFION-COATED ELECTRODES OR MEMBRANES [J].
HAYON, J ;
OZER, D ;
RISHPON, J ;
BETTELHEIM, A .
JOURNAL OF THE CHEMICAL SOCIETY-CHEMICAL COMMUNICATIONS, 1994, (05) :619-620
[25]  
HIBBS JB, 1987, J IMMUNOL, V138, P550
[26]   NITRIC-OXIDE - A CYTO-TOXIC ACTIVATED MACROPHAGE EFFECTOR MOLECULE [J].
HIBBS, JB ;
TAINTOR, RR ;
VAVRIN, Z ;
RACHLIN, EM .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 1988, 157 (01) :87-94
[27]   Nitric oxide complexes of metalloporphyrins: an overview of some mechanistic studies [J].
Hoshino, M ;
Laverman, L ;
Ford, PC .
COORDINATION CHEMISTRY REVIEWS, 1999, 187 :75-102
[28]   PRACTICAL NITRIC-OXIDE MEASUREMENT EMPLOYING A NITRIC OXIDE-SELECTIVE ELECTRODE [J].
ICHIMORI, K ;
ISHIDA, H ;
FUKAHORI, M ;
NAKAZAWA, H ;
MURAKAMI, E .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1994, 65 (08) :2714-2718
[29]   Determination of nitric oxide with ultramicrosensors based on electropolymerized films of metal tetraaminophthalocyanines [J].
Jin, JY ;
Miwa, T ;
Mao, LQ ;
Tu, HP ;
Jin, LT .
TALANTA, 1999, 48 (05) :1005-1011
[30]   Detection of nitric oxide with the iron (III) porphyrin doped nafion/glassy carbon electrode [J].
Kitajima, A ;
Miyake, M ;
Kobayashi, T ;
Koyama, H ;
Ikeda, O ;
Kijima, K ;
Komura, T ;
Uno, A ;
Yamatodani, A .
ELECTROCHEMISTRY, 1999, 67 (07) :784-788