Electromagnetic catheter navigation during bronchoscopy - Validation of a novel method by conventional fluoroscopy

被引:71
作者
Hautmann, H
Schneider, A
Pinkau, T
Peltz, F
Feussner, H
机构
[1] Tech Univ Munich, Klinikum Rechts Isar, Med Klin 1, D-81675 Munich, Germany
[2] Tech Univ Munich, Klinikum Rechts Isar, Workgrp MITI, D-81675 Munich, Germany
关键词
bronchoscopy; CT; diagnostic imaging; image-guided; stereotaxy; three-dimensional imaging; virtual bronchoscopy;
D O I
10.1378/chest.128.1.382
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Electromagnetic navigation in bronchoscopy is a novel method for assisting in the localization of peripheral lung lesions. Study objective: To assess the usability, accuracy, and safety of electromagnetic navigation during flexible bronchoscopy in a clinical setting. Design: Prospective evaluation. Patients: Consecutive patients referred to the bronchoscopy unit for the diagnosis of peripheral infiltrates or solitary pulmonary nodules (SPNs). Methods: Navigation was performed using an electromagnetic tracking system with a position sensor encapsulated in the tip of a flexible catheter that was pushed through the working channel of the bronchoscope. Real-time, multiplanar reconstruction of a previously acquired CT data set provided three-dimensional views for localization of the catheter. To match the position of the sensor with the CT scan, four anatomic landmarks were used for registration. The sensor position generated in the navigation system was controlled by fluoroscopy, and the corresponding error distances were measured. This was performed with all SPNs and at two different peripheral locations of the right upper lobe (RUL). Results: Sixteen patients (10 men and 6 women; mean age, 63.7 years) were studied. Navigation prolonged bronchoscopy by 3.9 +/- 1.3 min (mean +/- SD). The navigation system identified all lesions. The position sensor achieved a direct hit in three of five SPNs. Fluoroscopy failed to recognize three SPNs (60%) and three infiltrates (38%). The mean error distances between sensor tip position and fluoroscopically verified RUL reference position were 10.4 mm (lateral position) and 12.5 mm (apical position) respectively. The mean error distances between the sensor tip and two endobronchial registration points at the end of the procedure were 4.2 min and 5.1 mm, respectively. Conclusion: Electromagnetic navigation is useful, accurate, and safe in the localization of peripheral lung lesions and may help to improve the yield of diagnostic bronchoscopic procedures.
引用
收藏
页码:382 / 387
页数:6
相关论文
共 16 条
[1]   Diagnostic yield of fiberoptic bronchoscopy in evaluating solitary pulmonary nodules [J].
Baaklini, WA ;
Reinoso, MA ;
Gorin, AB ;
Sharafkanch, A ;
Manian, P .
CHEST, 2000, 117 (04) :1049-1054
[2]   BIOPSY AND BRUSHING OF PERIPHERAL LUNG-CANCER WITH FLUOROSCOPIC GUIDANCE [J].
CORTESE, DA ;
MCDOUGALL, JC .
CHEST, 1979, 75 (02) :141-145
[3]   TRANSBRONCHIAL LUNG-BIOPSY VIA FIBEROPTIC BRONCHOSCOPE - EXPERIENCE WITH 107 CONSECUTIVE CASES AND COMPARISON WITH BRONCHIAL BRUSHING [J].
ELLIS, JH .
CHEST, 1975, 68 (04) :524-532
[4]  
FLETCHER EC, 1982, WESTERN J MED, V136, P477
[5]   CT fluoroscopy guidance for transbronchial needle aspiration - An experience in 35 patients [J].
Garpestad, E ;
Goldberg, SN ;
Herth, F ;
Garland, R ;
LoCicero, J ;
Thurer, R ;
Ernst, A .
CHEST, 2001, 119 (02) :329-332
[6]   Mediastinal lymphadenopathy: Diagnostic yield of transbronchial mediastinal lymph node biopsy with CT fluoroscopic guidance - Initial experience [J].
Goldberg, SN ;
Raptopoulos, V ;
Boiselle, PM ;
Edinburgh, KJ ;
Ernst, A .
RADIOLOGY, 2000, 216 (03) :764-767
[7]   DIAGNOSTIC-ACCURACY IN PERIPHERAL LUNG LESIONS - FACTORS PREDICTING SUCCESS WITH FLEXIBLE FIBEROPTIC BRONCHOSCOPY [J].
RADKE, JR ;
CONWAY, WA ;
EYLER, WR ;
KVALE, PA .
CHEST, 1979, 76 (02) :176-179
[8]   Electromagnetic navigation during flexible bronchoscopy [J].
Schwarz, Y ;
Mehta, AC ;
Ernst, A ;
Herth, F ;
Engel, A ;
Besser, D ;
Becker, HD .
RESPIRATION, 2003, 70 (05) :516-522
[9]  
SHURE D, 1983, AM REV RESPIR DIS, V128, P1090
[10]   Real-time bronchoscope tip localization enables three-dimensional CT image guidance for transbronchial needle aspiration in swine [J].
Solomon, SB ;
White, P ;
Acker, DE ;
Strandberg, J ;
Venbrux, AC .
CHEST, 1998, 114 (05) :1405-1410