Human leukocyte antigen sensitization in ventricular assist device recipients: A lesser risk with the DeBakey axial pump

被引:11
作者
Grinda, JM
Bricourt, MO
Arnrein, C
Salvi, S
Guillemain, R
Francois, A
Guibourt, P
Deloche, A
Fabiani, JN
机构
[1] Hop Europeen Georges Pompidou, Dept Cardiovasc Surg & Thorac Transplantat, F-75908 Paris, France
[2] Hop Europeen Georges Pompidou, Blood Bank, F-75908 Paris, France
关键词
D O I
10.1016/j.athoracsur.2005.03.096
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Previous reports, all concerning pulsatile devices, have indicated an increased risk of development of circulating antileukocyte antigen (HLA; human leukocyte antigen) antibodies during ventricular assist device (VAD) support. We investigated sensitization in patients implanted with the DeBakey VAD (MicroMed Technology, Inc, Houston, TX) axial flow pump as a bridge to heart transplantation. Methods. Inclusion criteria for this prospective study were the following. Patients implanted with the DeBakey VAD axial flow pump, without HLA antibodies prior to implantation, with a duration of support of at least one month. The HLA antibody testing for IgG and IgM class I and II antibodies was performed weekly during support, using both a complement dependant cytotoxicity assay and an enzyme-linked immunosorbent assay (ELISA). Retrospective cross match was performed for all patients transplanted. The occurrence of graft rejection was determined by regular endomyocardial biopsies after heart transplantation, graded according to the International Society for Heart and Lung Transplantation (ISHLT) guidelines. Additionally, the transfusion history was reviewed for all patients. Results. Fourteen patients were included representing 1,220 cumulative patient-days of support (mean duration time on support, 87 days). No patient developed detectable IgG antibodies to class I or II. One patient had a positive ELISA, corresponding to nonsignificant (6/30) class I IgM antibodies at 3 weeks postimplantation. Ten patients underwent successful heart transplantation, representing 156 cumulative months. No retrospective cross match was positive. The percentage of significant acute rejection episodes (ISHLT grade 3A or more) was 6% and 4.3% in the first 6 months and from 6 to 12 months, respectively. No vascular rejection was noted. The posttransplantation survival rate was 87% at 6 months and 75% at 1 year, respectively. Conclusions. Patients implanted with the DeBakey VAD axial flow pump as a bridge to heart transplantation do not appear to be exposed to an increased risk of sensitization.
引用
收藏
页码:945 / 949
页数:5
相关论文
共 17 条
[1]   Transitory immunologic response after implantation of the DeBakey VAD continuous-axial-flow pump [J].
Ankersmit, HJ ;
Wieselthaler, G ;
Moser, B ;
Gerlitz, S ;
Roth, G ;
Boltz-Nitulescu, G ;
Wolner, E .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 123 (03) :557-561
[2]   Panel-reactive antibody screening practices prior to heart transplantation [J].
Betkowski, AS ;
Graff, R ;
Chen, JJ ;
Hauptman, PJ .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2002, 21 (06) :644-650
[3]  
Bishay ES, 2000, TRANSPLANTATION, V70, P220
[4]  
DeNofrio D, 2000, TRANSPLANTATION, V69, P814
[5]   Worldwide experience with the MicroMed DeBakey ventricular assist device® as a bridge to transplantation [J].
Goldstein, DJ .
CIRCULATION, 2003, 108 (10) :272-277
[6]   Human leukocyte antigen sensitization in ventricular assist device recipients: A lesser risk with the DeBakey axial pump [J].
Grinda, JM ;
Bricourt, MO ;
Arnrein, C ;
Salvi, S ;
Guillemain, R ;
Francois, A ;
Guibourt, P ;
Deloche, A ;
Fabiani, JN .
ANNALS OF THORACIC SURGERY, 2005, 80 (03) :945-949
[7]   Bridge to transplantation with the DeBakey VAD® axial pump:: a single center report [J].
Grinda, JM ;
Latremouille, CH ;
Chevalier, P ;
D'Attelis, N ;
Boughenou, F ;
Guillemain, R ;
Deloche, A ;
Fabiani, JN .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2002, 22 (06) :965-970
[8]   Pseudointima in inflow conduits of left ventricular assist devices [J].
Houel, R ;
Moczar, M ;
Clerin, V ;
Loisance, DY .
ANNALS OF THORACIC SURGERY, 1999, 68 (02) :717-723
[9]  
Itescu Silviu, 2003, Cardiology Clinics, V21, P119, DOI 10.1016/S0733-8651(02)00135-2
[10]   Immunologic sensitization in recipients of left ventricular assist devices [J].
John, R ;
Lietz, K ;
Schuster, M ;
Naka, J ;
Rao, V ;
Mancini, DM ;
Rose, EA ;
Smith, CR ;
Oz, MC ;
Edwards, NM ;
Itescu, S .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2003, 125 (03) :578-591