Aptamer-based rolling circle amplification: A platform for electrochemical detection of protein

被引:210
作者
Zhou, Long [1 ]
Ou, Li-Juan [1 ]
Chu, Xia [1 ]
Shen, Guo-Li [1 ]
Yu, Ru-Qin [1 ]
机构
[1] Hunan Univ, Coll Chem & Chem Engn, State Key Lab Chemo Biosensing & Chemomet, Changsha 410082, Peoples R China
关键词
D O I
10.1021/ac071059s
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Aptamer-based rolling circle amplification (aptamer-RCA) was developed as a novel versatile electrochemical platform for ultrasensitive detection of protein. Ibis method utilized antibodies immobilized on the electrode surface to capture the protein target, and the surface-captured protein was then sandwiched by an aptamer-primer complex. The aptamer-primer sequence mediated an in situ RCA reaction that generated hundreds of copies of a circular DNA template. Detection of the amplified copies via enzymatic silver deposition then allowed enormous sensitivity enhancement in the assay of target protein. This novel aptamer-primer design circumvented time-consuming preparation of the antibody-DNA conjugate for the common immuno-RCA assay. Moreover, the detection strategy based on enzymatic silver deposition enabled a highly efficient readout of the RCA product as compared to a redox-labeled probe based procedure that might exhibit low detection efficiency due to RCA product distance from the electrode. With the platelet-derived growth factor B-chain (PDGF-BB) as a model target, it was demonstrated that the presented method was highly sensitive and specific with a wide detection range of 4 orders of magnitude and a detection limit as low as 10 fM. Because of the wide availability of aptamers for numerous proteins, this platform holds great promise in ultrasensitive immunoassay.
引用
收藏
页码:7492 / 7500
页数:9
相关论文
共 49 条
[1]   Gold nanoparticle-based quantitative electrochemical detection of amplified human cytomegalovirus DNA using disposable microband electrodes [J].
Authier, L ;
Grossiord, C ;
Brossier, P ;
Limoges, B .
ANALYTICAL CHEMISTRY, 2001, 73 (18) :4450-4456
[2]   FILM STRIPPING VOLTAMMETRY [J].
BRAININA, KZ .
TALANTA, 1971, 18 (05) :513-&
[3]   The use of aptamers in large arrays for molecular diagnostics [J].
Brody, EN ;
Willis, MC ;
Smith, JD ;
Jayasena, S ;
Zichi, D ;
Gold, L .
MOLECULAR DIAGNOSIS, 1999, 4 (04) :381-388
[4]   Aptamer-based detection of plasma proteins by an electrochemical assay coupled to magnetic beads [J].
Centi, Sonia ;
Tombelli, Sara ;
Minunni, Maria ;
Mascini, Marco .
ANALYTICAL CHEMISTRY, 2007, 79 (04) :1466-1473
[5]   Piezoelectric immunosensor for the detection of immunoglobulin M [J].
Chu, X ;
Lin, ZH ;
Shen, GL ;
Yu, RQ .
ANALYST, 1995, 120 (12) :2829-2832
[6]   An electrochemical stripping metalloimmunoassay based on silver-enhanced gold nanoparticle label [J].
Chu, X ;
Fu, X ;
Chen, K ;
Shen, GL ;
Yu, RQ .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (09) :1805-1812
[7]   Pushing down the limits of detection: Molecular needles in a haystack [J].
Cousino, MA ;
Jarbawi, TB ;
Halsall, HB ;
Heineman, WR .
ANALYTICAL CHEMISTRY, 1997, 69 (17) :A544-A549
[8]   Gold nanoparticles: Assembly, supramolecular chemistry, quantum-size-related properties, and applications toward biology, catalysis, and nanotechnology [J].
Daniel, MC ;
Astruc, D .
CHEMICAL REVIEWS, 2004, 104 (01) :293-346
[9]   An enzyme-linked oligonucleotide assay [J].
Drolet, DW ;
MoonMcDermott, L ;
Romig, TS .
NATURE BIOTECHNOLOGY, 1996, 14 (08) :1021-1025
[10]   Synthetic DNA aptamers to detect protein molecular variants in a high-throughput fluorescence quenching assay [J].
Fang, XH ;
Sen, A ;
Vicens, M ;
Tan, WH .
CHEMBIOCHEM, 2003, 4 (09) :829-834