Amperometric biosensor for choline based on layer-by-layer assembled functionalized carbon nanotube and polyaniline multilayer film

被引:148
作者
Qu, FL [1 ]
Yang, MH [1 ]
Jiang, JH [1 ]
Shen, GL [1 ]
Yu, RQ [1 ]
机构
[1] Hunan Univ, Coll Chem & Chem Engn, State Key Lab Chemobiosensing & Chemometr, Changsha 410082, Peoples R China
基金
中国国家自然科学基金;
关键词
carbon nanotubes; polyaniline; electropolymerization; layer-by-layer; biosensing;
D O I
10.1016/j.ab.2005.06.007
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Conducting polymer film was prepared by electrochemical polymerization of aniline. Multiwalled carbon nanotubes (MWNTs) were treated with a mixture of concentrated sulfuric and nitric acid to introduce carboxylic acid groups to the nanotubes. By using the layer-by-layer method, homogeneous and stable MWNTs and polyaniline (PAN 1) multilayer films were alternately assembled on glassy carbon (GC) electrodes. Conducting polymer of PANI had three main functions: (i) excellent antiinterference ability, (ii) protection ability in favor of increasing the amount of the MWNTs immobilized on GC electrodes, and (iii) Superior transducing ability. The protection effect of PANI film and the electrostatic interaction between positively charged PANI and negatively charged MWNTs both attributed to immobilizing abundant MWNTs stably, thereby enhancing the catalytic activity. The layer-by-layer assembled MWNTs and PANI-modified GC electrodes offered a significant decrease in the overvoltage for the H2O2 and were shown to be excellent amperometric sensors for H2O2 from +0.2 V over a wide range of concentrations. As an application example, by linking choline oxidase (CHOD), an amplified biosensor toward choline was prepared. The choline biosensor exhibited a linear response range of 1 X 10(-6) to 2 x 10(-3) M with a correlation coefficient of 0.997, and the response time and detection limit (S/N = 3) were determined to be 3 s and 0.3 mu m, respectively. The antiinterference biosensor displays a rapid response and an expanded linear response range as well as excellent reproducibility and stability. (C) 2005 Elsevier Inc. All rights reserved.
引用
收藏
页码:108 / 114
页数:7
相关论文
共 22 条
  • [1] BUMSU K, 2003, LANGMUIR, V19, P2525
  • [2] Carbon fiber nanoelectrodes modified by single-walled carbon nanotubes
    Chen, RS
    Huang, WH
    Tong, H
    Wang, ZL
    Cheng, JK
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (22) : 6341 - 6345
  • [3] An amperometric urea biosensor based on a polyaniline-perfluorosulfonated ionomer composite electrode
    Cho, WJ
    Huang, HJ
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (18) : 3946 - 3951
  • [4] ELECTROCHEMICAL-BEHAVIOR, CHRONOCOULOMETRIC AND KINETIC-STUDY OF THE REDOX MECHANISM OF POLYANILINE DEPOSITS
    GENIES, EM
    TSINTAVIS, C
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1986, 200 (1-2): : 127 - 145
  • [5] Sol-gel-derived ceramic-carbon nanotube nanocomposite electrodes: Tunable electrode dimension and potential electrochemical applications
    Gong, KP
    Zhang, MN
    Yan, YM
    Su, L
    Mao, LQ
    Xiong, ZX
    Chen, Y
    [J]. ANALYTICAL CHEMISTRY, 2004, 76 (21) : 6500 - 6505
  • [6] BIOSENSOR BASED ON CONDUCTING POLYMERS
    HOA, DT
    KUMAR, TNS
    PUNEKAR, NS
    SRINIVASA, RS
    LAL, R
    CONTRACTOR, AQ
    [J]. ANALYTICAL CHEMISTRY, 1992, 64 (21) : 2645 - 2646
  • [7] Electrochemical biosensing platforms using platinum nanoparticles and carbon nanotubes
    Hrapovic, S
    Liu, YL
    Male, KB
    Luong, JHT
    [J]. ANALYTICAL CHEMISTRY, 2004, 76 (04) : 1083 - 1088
  • [8] HELICAL MICROTUBULES OF GRAPHITIC CARBON
    IIJIMA, S
    [J]. NATURE, 1991, 354 (6348) : 56 - 58
  • [9] Incorporation of functionalized single-wall carbon nanotubes in dye-sensitized TiO2 solar cells
    Jang, SR
    Vittal, R
    Kim, KJ
    [J]. LANGMUIR, 2004, 20 (22) : 9807 - 9810
  • [10] Organizing single-walled carbon nanotubes on gold using a wet chemical self-assembling technique
    Liu, ZF
    Shen, ZY
    Zhu, T
    Hou, SF
    Ying, LZ
    Shi, ZJ
    Gu, ZN
    [J]. LANGMUIR, 2000, 16 (08) : 3569 - 3573