Virtual Monochromatic Spectral Imaging for the Evaluation of Hypovascular Hepatic Metastases The Optimal Monochromatic Level With Fast Kilovoltage Switching Dual-Energy Computed Tomography

被引:93
作者
Yamada, Yoshitake [1 ]
Jinzaki, Masahiro [1 ]
Tanami, Yutaka [1 ]
Abe, Takayuki [2 ]
Kuribayashi, Sachio [1 ]
机构
[1] Keio Univ, Sch Med, Dept Diagnost Radiol, Shinjuku Ku, Tokyo 1608582, Japan
[2] Keio Univ, Sch Med, Clin Res Ctr, Shinjuku Ku, Tokyo 1608582, Japan
关键词
monochromatic; noise; contrast-to-noise ratio; liver; hepatic metastasis; HYPERVASCULAR LIVER-TUMORS; BEAM-HARDENING ARTIFACTS; LOW TUBE VOLTAGE; TOMOGRAPHIC APPARATUS; MULTIDETECTOR CT; ARTERIAL PHASE; NOISE; PROTOCOL;
D O I
10.1097/RLI.0b013e318240a874
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: The purpose of this study was to select the optimal monochromatic level for virtual monochromatic spectral (VMS) imaging to minimize the image noise of the liver parenchyma and to acquire a high contrast-to-noise ratio (CNR) of hypovascular hepatic metastases in the portal-dominant phase. Materials and Methods: This study was conducted with the approval of our institutional review board, and written informed consent was obtained from all the participating patients. Ninety patients with hepatic metastases were scanned by fast kilovoltage switching dual-energy computed tomography in the portal-dominant phase. One hundred one sets of VMS images in the range of 40 to 140 keV at 1-keV intervals were reconstructed. The image noise of the liver parenchyma in each patient and the CNR of each metastasis (n = 303) were measured on all the 101 VMS image sets. Data were analyzed by the paired t test and mixed-effects model. Bonferroni's method was used for multiple comparisons. Results: The lowest noise of the liver parenchyma was obtained in 6, 15, 31, 29, 7, 1, and 1 patient at 67, 68, 69, 70, 71, 72, and 73 keV, respectively. The mean noise of the liver parenchyma on the 69-keV VMS images in all 90 patients was significantly lower than that on the 67-, 68-, 71-, 72-, and 73-keV VMS images (P < 0.001); however, there was no significant difference in the mean noise of the liver parenchyma between the 69-keV and 70-keV VMS images (P = 0.279). For 95% of the hepatic metastases (288/303 metastases), the highest metastasis-to-liver CNR was obtained in the 66- to 71-keV VMS images. The mean metastasis-to-liver CNR for the 303 metastases was numerically highest at 68 keV; however, there was no significant difference in the mean metastasis-to-liver CNR between the 68-keV and 69-keV images (P = 0.737) or between the 68-keV and 70-keV images (P = 0.103). Conclusions: VMS imaging at approximately 70 keV (69-70 keV) yielded the lowest image noise of the liver parenchyma and a high CNR for hypovascular hepatic metastases in the portal-dominant phase.
引用
收藏
页码:292 / 298
页数:7
相关论文
共 42 条
  • [1] ENERGY-SELECTIVE RECONSTRUCTIONS IN X-RAY COMPUTERIZED TOMOGRAPHY
    ALVAREZ, RE
    MACOVSKI, A
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (05) : 733 - 744
  • [2] Blake MA, 2011, RADIOGRAPHICS, V31, P1047, DOI 10.1148/rg.314105159
  • [3] Dynamic Contrast-Enhanced CT Studies Balancing Patient Exposure and Image Noise
    Brix, Gunnar
    Lechel, Ursula
    Petersheim, Markus
    Krissak, Radko
    Fink, Christian
    [J]. INVESTIGATIVE RADIOLOGY, 2011, 46 (01) : 64 - 70
  • [4] TISSUE SIGNATURES WITH DUAL-ENERGY COMPUTED-TOMOGRAPHY
    DICHIRO, G
    BROOKS, RA
    KESSLER, RM
    JOHNSTON, GS
    JONES, AE
    HERDT, JR
    SHERIDAN, WT
    [J]. RADIOLOGY, 1979, 131 (02) : 521 - 523
  • [5] First performance evaluation of a dual-source CT (DSCT) system
    Flohr, TG
    McCollough, CH
    Bruder, H
    Petersilka, M
    Gruber, K
    Süss, C
    Grasruck, M
    Stierstorfer, K
    Krauss, B
    Raupach, R
    Primak, AN
    Küttner, A
    Achenbach, S
    Becker, C
    Kopp, A
    Ohnesorge, BM
    [J]. EUROPEAN RADIOLOGY, 2006, 16 (02) : 256 - 268
  • [6] QUANTITATIVE BONE-MINERAL ANALYSIS USING DUAL ENERGY COMPUTED TOMOGRAPHY
    GENANT, HK
    BOYD, D
    [J]. INVESTIGATIVE RADIOLOGY, 1977, 12 (06) : 545 - 551
  • [7] Dual energy CT: preliminary observations and potential clinical applications in the abdomen
    Graser, Anno
    Johnson, Thorsten R. C.
    Chandarana, Hersh
    Macari, Michael
    [J]. EUROPEAN RADIOLOGY, 2009, 19 (01) : 13 - 23
  • [8] Evaluation of Dual-Energy CT for Differentiating Intracerebral Hemorrhage from Iodinated Contrast Material Staining
    Gupta, Rajiv
    Phan, Catherine M.
    Leidecker, Christianne
    Brady, Thomas J.
    Hirsch, Joshua A.
    Nogueira, Raul G.
    Yoo, Albert J.
    [J]. RADIOLOGY, 2010, 257 (01) : 205 - 211
  • [9] Evaluation of non-linear blending in dual-energy computed tomography
    Holmes, David R., III
    Fletcher, Joel G.
    Apel, Anja
    Huprich, James E.
    Siddiki, Hassan
    Hough, David M.
    Schmidt, Bernhard
    Flohr, Thomas G.
    Robb, Richard
    McCollough, Cynthia
    Wittmer, Michael
    Eusemann, Christian
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2008, 68 (03) : 409 - 413
  • [10] Individual modulation of the tube current-seconds to achieve similar levels of image noise in contrast-enhanced abdominal CT
    Irie, T
    Inoue, H
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (05) : 1514 - 1518