Glucose response of dissolved-core alginate microspheres: towards a continuous glucose biosensor

被引:24
作者
Chaudhary, Ayesha [1 ]
McShane, Michael J. [2 ]
Srivastava, Rohit [1 ]
机构
[1] Indian Inst Technol, Dept Biosci & Bioengn, Mumbai, Maharashtra, India
[2] Texas A&M Univ, Dept Biomed Engn, Mat Sci & Engn Program, College Stn, TX 77843 USA
关键词
IN-VIVO; AFFINITY SENSOR; BLOOD-GLUCOSE; MACROMOLECULE ENCAPSULATION; CONCANAVALIN-A; BINDING; OXIDASE; PERFORMANCE; FILMS; ASSAY;
D O I
10.1039/c0an00109k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Microparticle optical sensors hold potential as implantable smart materials for in vivo analysis. In this work, the reversible response of dissolved-core alginate microspheres containing a homogeneous fluorescence resonance energy transfer (FRET)-based competitive binding assay for glucose was evaluated. The layer-by-layer self assembly technique was used to deposit multilayered nanofilm coatings on the alginate microspheres containing the assay, thereby stabilizing the sensor system when the alginate was de-crosslinked. The response to glucose was then determined in DI water and simulated interstitial fluid (SIF) using a flow cell to establish controlled, dynamic flow conditions for demonstrating reversibility. The glucose sensitivity under dynamic conditions was estimated to be 0.52%/mM glucose in DI water and 0.6%/mM glucose in simulated interstitial fluid; in both cases, the analytical response range was 0-30mM glucose, covering both physiological (normoglycemia) and pathophysiological range (hyperglycemia and hypoglycemia). The sensor demonstrated a repeatable and reproducible response when tested over a period of one month, under dynamic flow conditions. Finally, in vitro cytotoxicity assays performed with L929 mouse fibroblast cell lines suggested that the dissolved-core alginate microsphere sensor system with nanofilm coating has sufficient biocompatibility for use as implantable glucose biosensors.
引用
收藏
页码:2620 / 2628
页数:9
相关论文
共 66 条
[1]   A fluorescence affinity hollow fiber sensor for continuous transdermal glucose monitoring [J].
Ballerstadt, R ;
Schultz, JS .
ANALYTICAL CHEMISTRY, 2000, 72 (17) :4185-4192
[2]   In vitro long-term performance study of a near-infrared fluorescence affinity sensor for glucose monitoring [J].
Ballerstadt, R ;
Polak, A ;
Beuhler, A ;
Frye, J .
BIOSENSORS & BIOELECTRONICS, 2004, 19 (08) :905-914
[3]   In vivo performance evaluation of a transdermal near-infrared fluorescence resonance energy transfer affinity sensor for continuous glucose monitoring [J].
Ballerstadt, Ralph ;
Evans, Colton ;
Gowda, Ashok ;
McNichols, Roger .
DIABETES TECHNOLOGY & THERAPEUTICS, 2006, 8 (03) :296-311
[4]   Concanavalin A for in vivo glucose sensing: A biotoxicity review [J].
Ballerstadt, Ralph ;
Evans, Colton ;
McNichols, Roger ;
Gowda, Ashok .
BIOSENSORS & BIOELECTRONICS, 2006, 22 (02) :275-284
[5]  
Ballerstadt Ralph, 2004, Diabetes Technol Ther, V6, P191, DOI 10.1089/152091504773731375
[6]   Buildup of exponentially growing multilayer polypeptide films with internal secondary structure [J].
Boulmedais, F ;
Ball, V ;
Schwinte, P ;
Frisch, B ;
Schaaf, P ;
Voegel, JC .
LANGMUIR, 2003, 19 (02) :440-445
[7]   Continuous Glucose Sensing: Future Technology Developments [J].
Brauker, Jim .
DIABETES TECHNOLOGY & THERAPEUTICS, 2009, 11 :S25-S36
[8]   Enzymatic fluorescent microsphere glucose sensors: Evaluation of response under dynamic conditions [J].
Brown, J. Quincy ;
Srivastava, Rohit ;
Zhu, Huiguang ;
McShane, Michael J. .
DIABETES TECHNOLOGY & THERAPEUTICS, 2006, 8 (03) :288-295
[9]   Encapsulation of glucose oxidase and an oxygen-quenched fluorophore in polyelectrolyte-coated calcium alginate microspheres as optical glucose sensor systems [J].
Brown, JQ ;
Srivastava, R ;
McShane, MJ .
BIOSENSORS & BIOELECTRONICS, 2005, 21 (01) :212-216
[10]   pH-responsive properties of multilayered poly(L-lysine)/hyaluronic acid surfaces [J].
Burke, SE ;
Barrett, CJ .
BIOMACROMOLECULES, 2003, 4 (06) :1773-1783