Determination of Copper in Food and Water by Dispersive Liquid-Liquid Microextraction and Flame Atomic Absorption Spectrometry

被引:30
作者
Al Othman, Zeid [1 ]
Unsal, Yunus Emre [2 ]
Habila, Mohamed [1 ]
Shabaka, Aza [3 ]
Tuzen, Mustafa [2 ]
Soylak, Mustafa [4 ]
机构
[1] King Saud Univ, Coll Sci, Dept Chem, Adv Mat Res Chair, Riyadh 11451, Saudi Arabia
[2] Gaziosmanpasa Univ, Fac Sci Arts, Dept Chem, Tokat, Turkey
[3] Univ Alexandria, High Inst Publ Hlth, Dept Environm Hlth, Alexandria, Egypt
[4] Erciyes Univ, Dept Chem, Fen Fak, Kayseri, Turkey
关键词
Preconcentration; Food; Copper(II); 1-butyl-3-methylimidazolium hexafluorophosphate; Flame atomic absorption spectrometry; Microextraction; SOLID-PHASE EXTRACTION; OPTICAL-EMISSION-SPECTROMETRY; CLOUD-POINT EXTRACTION; MICROWAVE-ASSISTED DIGESTION; ENVIRONMENTAL-SAMPLES; IONIC LIQUID; TRACE AMOUNTS; FAAS DETERMINATION; HEAVY-METALS; SOIL SAMPLES;
D O I
10.1080/00032719.2014.999276
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new, simple, and rapid ionic liquid based dispersive liquid-liquid microextraction method is reported for the determination of copper with flame atomic absorption spectrometry. The ionic liquid, 1-butyl-3-methylimidazolium hexafluorophosphate, was used to extract a copper(II)- curcumin complex. The optimum extraction efficiency of copper was obtained after optimization of the ionic liquid volume, pH, centrifugation speed and time, ultrasonic bath time and temperature, and mass of curcumin. The effects of various ions on the recovery of copper(II) were also investigated. The preconcentration factor was 135. In the optimum experimental conditions, the limit of detection and the relative standard deviation were 0.19 microgram per liter and 4.1 percent, respectively. The method was validated by the analysis of certified reference materials and applied to food and water.
引用
收藏
页码:1738 / 1750
页数:13
相关论文
共 53 条
[1]   Association of Environmental Toxic Elements in Biological Samples of Myocardial Infarction Patients at Different Stages [J].
Afridi, Hassan Imran ;
Kazi, Tasneem Gul ;
Kazi, Naveed ;
Kandhro, Ghulam Abbas ;
Baig, Jameel Ahmed ;
Jamali, Mohammad Khan ;
Arain, Mohammad Balal ;
Shah, Abdul Qadir ;
Shah, Faheem ;
Khan, Sumaira ;
Kolachi, Nida Fatima .
BIOLOGICAL TRACE ELEMENT RESEARCH, 2011, 141 (1-3) :26-40
[2]   Membrane filtration of Sudan orange G on a cellulose acetate membrane filter for separation-preconcentration and spectrophotometric determination in water, chili powder, chili sauce and tomato sauce samples [J].
AlOthman, Zeid A. ;
Unsal, Yunus E. ;
Habila, Mohamed ;
Shabaka, Azza ;
Tuzen, Mustafa ;
Soylak, Mustafa .
FOOD AND CHEMICAL TOXICOLOGY, 2012, 50 (08) :2709-2713
[3]   Application of principal component analysis to the study of major cations and trace metals in fish from Tenerife (Canary Islands) [J].
Astorga-España, MS ;
Peña-Méndez, EM ;
García-Montelongo, FJ .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1999, 49 (02) :173-178
[4]  
Ayyat M. S., 1995, World Rabbit Science, V3, P113
[5]   Separation and preconcentration of lead, chromium and copper by using with the combination coprecipitation-flame atomic absorption spectrometric determination [J].
Bahadir, Zekeriyya ;
Bulut, Volkan Numan ;
Ozdes, Duygu ;
Duran, Celal ;
Bektas, Hakan ;
Soylak, Mustafa .
JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2014, 20 (03) :1030-1034
[6]   Determination of Total Chromium at Ultratrace Levels in Water and Soil Samples by Coprecipitation Microsample Injection System Flame Atomic Absorption Spectrometry [J].
Baig, Jameel Ahmed ;
Elci, Latif ;
Khan, Muhammad Irfan ;
Kazi, Tasneem Gul .
JOURNAL OF AOAC INTERNATIONAL, 2014, 97 (05) :1421-1425
[7]   Determination of heavy metals in soils and sediments by microwave-assisted digestion and inductively coupled plasma optical emission spectrometry analysis [J].
Bettinelli, M ;
Beone, GM ;
Spezia, S ;
Baffi, C .
ANALYTICA CHIMICA ACTA, 2000, 424 (02) :289-296
[8]   Green Preconcentration of Trace Amounts of Copper from Water and Food Samples onto Novel Organo-Nanoclay Prior to Flame Atomic Absorption Spectrometry [J].
Beyki, Mostafa Hossein ;
Shemirani, Farzaiveh ;
Khani, Rouhollah .
JOURNAL OF AOAC INTERNATIONAL, 2014, 97 (05) :1426-1433
[9]   Ligandless cloud point extraction of Cr(III), Pb(II), Cu(II), Ni(II), Bi(III), and Cd(II) ions in environmental samples with Tween 80 and flame atomic absorption spectrometric determination [J].
Candir, Secil ;
Narin, Ibrahim ;
Soylak, Mustafa .
TALANTA, 2008, 77 (01) :289-293
[10]   Synthesis and application of chloromethylated polystyrene modified with 1-phenyl-1,2-propanedione-2-oxime thiosemicarbazone (PPDOT) as a new sorbent for the on-line preconcentration and determination of copper in water, soil, and food samples by FAAS [J].
Chamjangali, Mansour Arab ;
Bagherian, Ghadamali ;
Mokhlesian, Ali ;
Bahramian, Bahram .
JOURNAL OF HAZARDOUS MATERIALS, 2011, 192 (03) :1641-1649