Performance optimisation of a new-generation orthogonal-acceleration quadrupole-time-of-flight mass spectrometer

被引:32
作者
Bristow, Tony [1 ]
Constantine, Jill [1 ]
Harrison, Mark [1 ]
Cavoit, Fabien [1 ]
机构
[1] AstraZeneca, Proc Res & Dev, Macclesfield SK10 2NA, Cheshire, England
关键词
D O I
10.1002/rcm.3499
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Orthogonal-acceleration quadrupole time-of-flight (oa-QTOF) mass spectrometers, employed for accurate mass measurement, have been commercially available for well over a decade. A limitation of the early instruments of this type was the narrow ion abundance range over which accurate mass measurements could be made with a high degree of certainty. Recently, a new generation of oa-QTOF mass spectrometers has been developed and these allow accurate mass measurements to be recorded over a much greater range of ion abundances. This development has resulted from new ion detection technology and improved electronic stability or by accurate control of the number of ions reaching the detector. In this report we describe the results from experiments performed to evaluate the mass measurement performance of the Bruker micrOTOF-Q (TM), a member of the new-generation oa-QTOFs. The relationship between mass accuracy and ion abundance has been extensively evaluated and mass measurement accuracy remained stable (+/- 1.5 m m/z units) over approximately 3-4 orders of magnitude of ion abundance. The second feature of the Bruker micrOTOF-Q (TM) that was evaluated was the Sigmafit (TM) function of the software. This isotope pattern-matching algorithm provides an exact numerical comparison of the theoretical and measured isotope patterns as an additional identification tool to accurate mass measurement. The smaller the value, the closer the match between theoretical and measured isotope patterns. This information is then employed to reduce the number of potential elemental formulae produced from the mass measurements. A relationship between the SigmaFit (TM) value and ion abundance has been established. The results from the study for both mass accuracy and SigmaFit (TM) were employed to define the performance criteria for the micrOTOF-Q (TM). This provided increased confidence in the selection of elemental formulae resulting from accurate mass measurements. Copyright (c) 2008 John Wiley & Sons, Ltd.
引用
收藏
页码:1213 / 1222
页数:10
相关论文
共 21 条
[1]   Estimating the precision of exact mass measurements on an orthogonal time-of-flight mass spectrometer [J].
Blom, KF .
ANALYTICAL CHEMISTRY, 2001, 73 (03) :715-719
[2]   Intercomparison study on accurate mass measurement of small molecules in mass spectrometry [J].
Bristow, AWT ;
Webb, KS .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2003, 14 (10) :1086-1098
[3]   Matrix effects on accurate mass measurements of low-molecular weight compounds using liquid chromatography-electrospray-quadrupole time-of-flight mass spectrometry [J].
Calbiani, F ;
Careri, M ;
Elviri, L ;
Mangia, A ;
Zagnoni, I .
JOURNAL OF MASS SPECTROMETRY, 2006, 41 (03) :289-294
[4]   An introduction to quadrupole-time-of-flight mass spectrometry [J].
Chernushevich, IV ;
Loboda, AV ;
Thomson, BA .
JOURNAL OF MASS SPECTROMETRY, 2001, 36 (08) :849-865
[5]   A fully automated method for accurate mass determination using high-performance liquid chromatography with a quadrupole/orthogonal acceleration time-of-flight mass spectrometer [J].
Colombo, M ;
Sirtori, FR ;
Rizzo, V .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (04) :511-517
[6]   Exact-mass library for pesticides using a molecular-feature database [J].
Ferrer, Imma ;
Fernandez-Alba, Amadeo ;
Zweigenbaum, Jerry A. ;
Thurman, E. Michael .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (24) :3659-3668
[7]   Tandem mass spectrometric accurate mass performance of time-of-flight and Fourier transform ion cyclotron resonance mass spectrometry: a case study with pyridine derivatives [J].
Hau, J ;
Stadler, R ;
Jenny, TA ;
Fay, LB .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (19) :1840-1848
[8]   Exact mass measurement of product ions for the structural elucidation of drug metabolites with a tandem quadrupole orthogonal-acceleration time-of-flight mass spectrometer [J].
Hopfgartner, G ;
Chernushevich, IV ;
Covey, T ;
Plomley, JB ;
Bonner, R .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1999, 10 (12) :1305-1314
[9]   Use of quadrupole time-of-flight mass spectrometry in the elucidation of unknown compounds present in environmental water [J].
Ibáñez, M ;
Sancho, JV ;
Pozo, OJ ;
Niessen, W ;
Hernández, F .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (02) :169-178
[10]   Strategies to avoid false negative findings in residue analysis using liquid chromatography coupled to time-of-flight mass spectrometry [J].
Kaufmann, Anton ;
Butcher, Patrick .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (23) :3566-3572