Strategies to avoid false negative findings in residue analysis using liquid chromatography coupled to time-of-flight mass spectrometry

被引:45
作者
Kaufmann, Anton [1 ]
Butcher, Patrick [1 ]
机构
[1] Kantonales Labor Zurich, Official Food Control Author Canton Zurich, CH-8032 Zurich, Switzerland
关键词
D O I
10.1002/rcm.2762
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Liquid chromatography coupled to orthogonal acceleration time-of-flight mass spectrometry (LC/TOF) provides an attractive alternative to liquid chromatography coupled to triple quadrupole mass spectrometry (LC/MS/MS) in the field of multiresidue analysis. The sensitivity and selectivity of LC/TOF approach those of LC/MS/MS. TOF provides accurate mass information and a significantly higher mass resolution than quadrupole analyzers. The available mass resolution of commercial TOF instruments ranging from 10 000 to 18 000 full width at half maximum (FWHM) is not, however, sufficient to completely exclude the problem of isobaric interferences (co-elution of analyte ions with matrix compounds of very similar mass). Due to the required data storage capacity, TOF raw data is commonly centroided before being electronically stored. However, centroiding can lead to a loss of data quality. The co-elution of a low intensity analyte peak with an isobaric, high intensity matrix compound can cause problems. Some centroiding algorithms might not be capable of deconvoluting such partially merged signals, leading to incorrect centroids. Co-elution of isobaric compounds has been deliberately simulated by injecting diluted binary mixtures of isobaric model substances at various relative intensities. Depending on the mass differences between the two isobaric compounds and the resolution provided by the TOF instrument, significant deviations in exact mass measurements and signal intensities were observed. The extraction of a reconstructed ion chromatogram based on very narrow mass windows can even result in the complete loss of the analyte signal. Guidelines have been proposed to avoid such problems. The use of sub-2 mu m HPLC packing materials is recommended to improve chromatographic resolution and to reduce the risk of co-elution. The width of the extraction mass windows for reconstructed ion chromatograms should be defined according to the resolution of the TOF instrument. Alternative approaches include the spiking of the sample with appropriate analyte concentrations. Furthermore, enhanced software, capable of deconvoluting partially merged mass peaks, may become available. Copyright (c) 2006 John Wiley & Sons, Ltd.
引用
收藏
页码:3566 / 3572
页数:7
相关论文
共 9 条
[1]  
[Anonymous], 2004, METHODOLOGY ACCURATE
[2]   Estimating the precision of exact mass measurements on an orthogonal time-of-flight mass spectrometer [J].
Blom, KF .
ANALYTICAL CHEMISTRY, 2001, 73 (03) :715-719
[3]   Matrix effects on accurate mass measurements of low-molecular weight compounds using liquid chromatography-electrospray-quadrupole time-of-flight mass spectrometry [J].
Calbiani, F ;
Careri, M ;
Elviri, L ;
Mangia, A ;
Zagnoni, I .
JOURNAL OF MASS SPECTROMETRY, 2006, 41 (03) :289-294
[4]   Versatile TOFMS [J].
Cottingham, K .
ANALYTICAL CHEMISTRY, 2005, 77 (11) :227A-231A
[5]   Liquid chromatography with time-of-flight mass spectrometry for simultaneous determination of chemotherapeutant residues in salmon [J].
Hernando, MD ;
Mezcua, M ;
Suárez-Barcena, JM ;
Fernández-Alba, AR .
ANALYTICA CHIMICA ACTA, 2006, 562 (02) :176-184
[6]   Screening and confirmation criteria for hormone residue analysis using liquid chromatography accurate mass time-of-flight, Fourier transform ion cyclotron resonance and orbitrap mass spectrometry techniques [J].
Nielen, M. W. F. ;
van Engelen, M. C. ;
Zuiderent, R. ;
Ramaker, R. .
ANALYTICA CHIMICA ACTA, 2007, 586 (1-2) :122-129
[7]   Isotopic pattern and accurate mass determination in urine drug screening by liquid chromatography/time-of-flight mass spectrometry [J].
Ojanperä, S ;
Pelander, A ;
Pelzing, M ;
Krebs, I ;
Vuori, E ;
Ojanperä, I .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (07) :1161-1167
[8]  
PRICE G, 2002, P 50 ASMS C MASS SPE
[9]   Investigations into the accuracy and precision obtainable on accurate mass measurements on a quadrupole orthogonal acceleration time-of-flight mass spectrometer using liquid chromatography as sample introduction [J].
Wolff, JC ;
Fuentes, TR ;
Taylor, J .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (11) :1216-1219