Black-blood diffusion-weighted EPI acquisition of the liver with parallel imaging - Comparison with a standard T2-weighted sequence for detection of focal liver lesions

被引:83
作者
Zech, Christoph J. [1 ]
Herrmann, Karin A. [1 ]
Dietrich, Olaf [1 ]
Horger, Wilhelm [2 ]
Reiser, Maximilian F. [1 ]
Schoenberg, Stefan O. [1 ,3 ]
机构
[1] Univ Munich, Inst Clin Radiol, Univ Hosp Munich Grosshadern, D-81377 Munich, Germany
[2] Siemens Med Solut, Erlangen, Germany
[3] Univ Heidelberg, Univ Hosp Mannheim, Med Fac Mannheim, Inst Clin Radiol, D-6900 Heidelberg, Germany
关键词
MRI liver; parallel imaging; diffusion-weighted sequences; echo-planar imaging; respiratory triggering;
D O I
10.1097/RLI.0b013e31816200b5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To evaluate the performance of black-blood diffusion-weighted (DW)-EPI sequences with parallel imaging for the detection of focal liver lesions in comparison with a standard T2-weighted (T2-w) sequence. Materials and Methods: Twenty patients with known or suspected focal liver lesions underwent liver MRI using a DW-EPI sequence with a b-value of 50 S/mm(2) JR/TE 2200/50 ms) and a standard fat-saturated T2-w sequence (TR/TE 2800/107 ms) with 6-mm slice thickness on a 1.5-T MR1 system. Both sequences used parallel imaging with an acceleration factor of 2. Overall image quality and degree of artifacts were compared on a 5-point scale with 5 being the most desirable score. The detection rate and the level of confidence with regard to lesion detection were evaluated for both sequences in comparison to a contrast-enhanced (Gadolinium and SPIO) MR examination, which was used as the standard of reference. Results: The DW-EPI sequence showed significantly (P < 0.05) improved overall image quality (average score 4.15 vs. 3.63) and fewer artifacts (average score 4.2 vs. 3.5) in comparison with the T2-w sequence. The sensitivity for lesion detection was superior in the DW-EPI sequence (83% vs. 61%). The level of confidence in the detection of focal liver lesions was also superior for the DW-EPI sequence in comparison with the T2-w sequence (average score 3.9 vs. 3.2). Conclusions: DW-EPI sequences for liver-imaging are feasible with parallel imaging and show excellent image quality. They may contribute to more easy and confident lesion detection in comparison with T2-w sequences.
引用
收藏
页码:261 / 266
页数:6
相关论文
共 23 条
  • [1] BRUNS GL, 1996, ARACHNE, V3, P1
  • [2] In vivo diffusion-weighted imaging of liver tumor necrosis in the VX2 rabbit model at 1.5 Tesla
    Deng, J
    Rhee, TK
    Sato, KT
    Salem, R
    Haines, K
    Paunesku, T
    Mulcahy, MF
    Miller, FH
    Omary, RA
    Larson, AC
    [J]. INVESTIGATIVE RADIOLOGY, 2006, 41 (04) : 410 - 414
  • [3] Multishot diffusion-weighted PROPELLER magnetic resonance imaging of the abdomen
    Deng, Jie
    Miller, Frank H.
    Salem, Riad
    Omary, Reed A.
    Larson, Andrew C.
    [J]. INVESTIGATIVE RADIOLOGY, 2006, 41 (10) : 769 - 775
  • [4] Can a single-shot black-blood T2-weighted spin-echo echo-planar imaging sequence with sensitivity encoding replace the respiratory-triggered turbo spin-echo sequence for the liver? An optimization and feasibility study
    Hussain, SM
    De Becker, J
    Hop, WCJ
    Dwarkasing, S
    Wielopolski, PA
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (03) : 219 - 229
  • [5] Diffusion-weighted MR imaging with single-shot echo-planar imaging in the upper abdomen: preliminary clinical experience in 61 patients
    Ichikawa, T
    Haradome, H
    Hachiya, J
    Nitatori, T
    Araki, T
    [J]. ABDOMINAL IMAGING, 1999, 24 (05): : 456 - 461
  • [6] Technologic advances in abdominal MR imaging
    Keogan, MT
    Edelman, RR
    [J]. RADIOLOGY, 2001, 220 (02) : 310 - 320
  • [7] Nephrogenic systemic fibrosis - A review of 6 cases temporally related to gadodiamide injection (Omniscan)
    Khurana, Anand
    Runge, Val M.
    Narayanan, Mohanram
    Greene, John F., Jr.
    Nickel, Allan E.
    [J]. INVESTIGATIVE RADIOLOGY, 2007, 42 (02) : 139 - 145
  • [8] Diffusion-weighted single-shot echoplanar MR imaging for liver disease
    Kim, T
    Murakami, T
    Takahashi, S
    Hori, M
    Tsuda, K
    Nakamura, H
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 173 (02) : 393 - 398
  • [9] Evaluation of super paramagnetic iron oxide-enhanced diffusion-weighted PROPELLER T2-fast spin echo magnetic resonance imaging - Preliminary experience
    Kiryu, S
    Watanabe, M
    Kabasawa, H
    Akahane, M
    Aoki, S
    Ohtomo, K
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2006, 30 (02) : 197 - 200
  • [10] Apparent diffusion coefficient measurements with diffusion-weighted magnetic resonance imaging for evaluation of hepatic fibrosis
    Koinuma, M
    Ohashi, I
    Hanafusa, K
    Shibuya, H
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 22 (01) : 80 - 85