Voltammetric and amperometric determination of sulfite using an aluminum electrode modified by nickel pentacyanonitrosylferrate film - Application to the analysis of some real samples

被引:58
作者
Pournaghi-Azar, MH [1 ]
Hydarpour, M
Dastangoo, H
机构
[1] Univ Tabriz, Fac Chem, Electroanalyt Chem Lab, Tabriz, Iran
[2] Res Inst Fundamental Sci, Tabriz 51664, Iran
关键词
nickel pentacyanonitrosylferrate; sulfite; electrocatalytic oxidation; amperometry; aluminum electrode; modified electrode;
D O I
10.1016/j.aca.2003.08.014
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A nickel pentacyanonitrosylferrate (NiPCNF) film modified/Al electrode prepared by a simple and rapid electroless dipping procedure was used for the mediated oxidation of sulfite. The anodic peak current observed in both cyclic voltammetry and constant potential amperometry under hydrodynamic conditions was linearly dependent on the sulfite concentration. The detection limit of the ampeorometric method was 3 x 10(-6) M, low enough for the trace sulfite determination. The analysis with NiPCNF film/Al electrode was selective for sulfite from some concomitant compounds. The proposed hydrodynamic amperometric method was used for the determination of sulfite in sulfite treated sugar, boiler water, sulfur dioxide treated raisins, and dried apricots. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:133 / 141
页数:9
相关论文
共 34 条
[11]   Measurement of sulfite at oxide-coated copper electrodes [J].
Kiattipoomchai, M ;
Somasundrum, M ;
Tanticharoen, M ;
Kirtikara, K .
ANALYST, 1998, 123 (10) :2017-2019
[12]   ELECTROLYTE-CATION-DEPENDENT COLORING, ELECTROCHROMISM AND THERMOCHROMISM OF COBALT(II) HEXACYANOFERRATE(III,II) FILMS [J].
KULESZA, PJ ;
MALIK, MA ;
ZAMPONI, S ;
BERRETTONI, M ;
MARASSI, R .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 397 (1-2) :287-292
[13]   Chemiluminescence determination of sulfite in sugar and sulfur dioxide in air using tris(2,2′-bipyridyl)ruthenium(II)-permanganate system [J].
Meng, H ;
Wu, FW ;
He, ZK ;
Zeng, YE .
TALANTA, 1999, 48 (03) :571-577
[14]  
Monnier G., 1972, ANALYST, V95, P119
[15]   SENSITIZED DETERMINATION OF SULFITE USING FLOW-INJECTION WITH CHEMILUMINESCENT DETECTION [J].
PAULLS, DA ;
TOWNSHEND, A .
ANALYST, 1995, 120 (02) :467-469
[16]  
POLYAYEVA IV, 1997, ANAL CHIN ACTA, V357
[17]   Electrocatalytic characteristics of ascorbic acid oxidation at nickel plated aluminum electrodes modified with nickel pentacyanonitrosylferrate films [J].
Pournaghi-Azar, MH ;
Razmi-Nerbin, H .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2000, 488 (01) :17-24
[18]   Voltammetric behaviour and electrocatalytic activity of the aluminum electrode modified with nickel and nickel hexacyanoferrate films, prepared by electroless deposition [J].
Pournaghi-Azar, MH ;
Razmi-Nerbin, H .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1998, 456 (1-2) :83-90
[19]  
Pournaghi-Azar MH, 2000, ELECTROANAL, V12, P209, DOI 10.1002/(SICI)1521-4109(200002)12:3<209::AID-ELAN209>3.0.CO
[20]  
2-I