Effect of scattered radiation on image noise in cone beam CT

被引:176
作者
Endo, M
Tsunoo, T
Nakamori, N
Yoshida, K
机构
[1] Natl Inst Radiol Sci, Inage Ku, Chiba 2638555, Japan
[2] Kyoto Inst Technol, Sakyo Ku, Kyoto 6068585, Japan
[3] Chiba Univ, Sch Med, Chuo Ku, Chiba 2608677, Japan
关键词
cone beam CT; scattered radiation; flat-panel imager; image noise;
D O I
10.1118/1.1357457
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Cone beam CT has a capability for the 3-dimensional imaging of large volumes with isotropic resolution, and has a potentiality for 4-dimensional imaging (dynamic volume imaging), because cone beam CT acquires data of a large volume with one rotation of an x-ray tube-detector pair. However, one of the potential drawbacks of cone beam CT is a larger amount of scattered x-rays, which may enhance the noise in reconstructed images, and thus affect the low-contrast detectablity. Our aim in this work was to estimate the scatter fractions and effects of scatter on image noise, and to seek methods of improving image quality in cone beam CT. First we derived a relationship between the noise in a reconstructed image and in an x-ray intensity measurement. Then we estimated the scatter to primary ratios in x-ray measurements using a Monte-Carlo simulation. From these we estimated the image noise under relevant clinical conditions. The results showed that the scattered radiation made a substantial contribution to the image noise. However, focused collimators could improve it by decreasing the scattered radiation drastically while keeping the primary radiation at nearly the same level. A conventional grid also improve the image noise, though the improvement was less than that of focused collimators. (C) 2001 American Association of Physicists in Medicine.
引用
收藏
页码:469 / 474
页数:6
相关论文
共 15 条
[1]   Empirical investigation of the signal performance of a high-resolution, indirect detection, active matrix flat-panel imager (AMFPI) for fluoroscopic and radiographic operation [J].
Antonuk, LE ;
ElMohri, Y ;
Siewerdsen, JH ;
Yorkston, J ;
Huang, W ;
Scarpine, VE ;
Street, RA .
MEDICAL PHYSICS, 1997, 24 (01) :51-70
[2]   COMPUTATION OF BREMSSTRAHLUNG X-RAY-SPECTRA AND COMPARISON WITH SPECTRA MEASURED WITH A GE(LI) DETECTOR [J].
BIRCH, R ;
MARSHALL, M .
PHYSICS IN MEDICINE AND BIOLOGY, 1979, 24 (03) :505-517
[3]   NOISE DUE TO PHOTON-COUNTING STATISTICS IN COMPUTED X-RAY TOMOGRAPHY [J].
CHESLER, DA ;
RIEDERER, SJ ;
PELC, NJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1977, 1 (01) :64-74
[4]   Image characteristics and effective dose estimation of a cone beam CT using a video-fluoroscopic system [J].
Endo, M ;
Nishizawa, K ;
Iwai, K ;
Matsumoto, M ;
Yoshida, K ;
Satoh, K ;
Matsusita, M ;
Kusakabe, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) :686-690
[5]  
Endo M, 1998, Radiat Med, V16, P7
[6]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[7]  
Hubbell J. H., 1975, Journal of Physical and Chemical Reference Data, V4, P471, DOI 10.1063/1.555523
[8]   PHOTON MASS ATTENUATION AND ENERGY-ABSORPTION COEFFICIENTS FROM 1 KEV TO 20 MEV [J].
HUBBELL, JH .
INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1982, 33 (11) :1269-1290
[9]   EFFECTS OF SCATTERED X-RAYS ON CT IMAGES [J].
KANAMORI, H ;
NAKAMORI, N ;
INOUE, K ;
TAKENAKA, E .
PHYSICS IN MEDICINE AND BIOLOGY, 1985, 30 (03) :239-249
[10]   Image intensifier-based computed tomography volume scanner for angiography [J].
Ning, R ;
Kruger, RA .
ACADEMIC RADIOLOGY, 1996, 3 (04) :344-350