Dual-energy CT behavior of heroin, cocaine, and typical adulterants

被引:3
作者
Laberke, Patrick J. [1 ,2 ]
Fornaro, Juergen [3 ]
Kim, Suk-kyum [3 ]
Blum, Simon [1 ]
Augsburger, Marc [4 ]
Alkadhi, Hatem [5 ]
Wildermuth, Simon [3 ]
Hausmann, Roland [1 ]
Leschka, Sebastian [3 ,5 ]
机构
[1] Kantonsspital St Gallen, Inst Legal Med, St Gallen, Switzerland
[2] Univ Zurich, Inst Forens Med, CH-8057 Zurich, Switzerland
[3] Kantonsspital St Gallen, St Gallen, Switzerland
[4] CURML, Univ Ctr Legal Med, Lausanne, Switzerland
[5] Univ Zurich Hosp, Inst Diagnost & Intervent Radiol, CH-8091 Zurich, Switzerland
关键词
Dual-energy CT; Bodypack; Cocaine; Heroin; Adulterants; COMPUTED-TOMOGRAPHY; BODY PACKING; DIFFERENTIATION;
D O I
10.1007/s12024-014-9643-7
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
030101 [法学理论]; 030111 [法律史学]; 100218 [急诊医学];
摘要
To investigate the dual-energy CT behavior of cocaine and heroin and of typical adulterants, and to evaluate the elemental composition of pure cocaine and heroin compared with cocaine and heroin in bodypacks. Pure heroin and pure synthetic cocaine samples, eight different adulterants, and in each case ten different bodypacks containing cocaine or heroin, were imaged at 80, 100, 120, and 140 kVp in a dual source CT system at two different degrees of compression. Two radiologists, blinded to the samples, measured the attenuation. The dual-energy index (DEI) was calculated. We performed atomic mass spectrometry for the elemental analysis of pure cocaine, pure heroin, and heroin and cocaine in bodypacks, and 140 kVp in a dual-source CT system. Inter- and intra-observer agreement for attenuation measurements was good (r = 0.61-0.72; p < 0.01). The cocaine bodypacks had a positive DEI of 0.029, while the pure drugs and the heroin bodypacks had a negative DEI (-0.051 to -0.027). Levamisole was the only substance which expressed a positive DEI of 0.011, while the remaining adulterants had negative DEIs ranging between -0.015 and -0.215. Atomic mass spectrometry revealed a concentration of tin in the cocaine bodypack that was 67 times higher than in the pure synthetic cocaine sample. The different DEIs of bodypacks containing cocaine and heroin allow them to be distinguished with dual-energy CT. Although the material properties of pure cocaine, pure heroin, or common drug extenders do not explain the differences in DEI, tin contamination during illicit natural cocaine production may be a possible explanation.
引用
收藏
页码:20 / 28
页数:9
相关论文
共 14 条
[1]
In vivo characterization of urinary calculi on dual-energy CT: going a step ahead with sub-differentiation of calcium stones [J].
Acharya, Sudeep ;
Goyal, Ankur ;
Bhalla, Ashu Seith ;
Sharma, Raju ;
Seth, Amlesh ;
Gupta, Arun Kumar .
ACTA RADIOLOGICA, 2015, 56 (07) :881-889
[2]
Role of radiology in a national initiative to interdict drug smuggling: The Dutch experience [J].
Algra, Paul R. ;
Brogdon, Byron G. ;
Marugg, Roque C. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (02) :331-336
[3]
Brogdon, 2011, BROGDONS FORENSIC RA, P311
[4]
Casale J F, 1993, Forensic Sci Rev, V5, P95
[5]
"Drug mules" as a radiological challenge: Sensitivity and specificity in identifying internal cocaine in body packers, body pushers and body stuffers by computed tomography, plain radiography and Lodox [J].
Flach, Patricia M. ;
Ross, Steffen G. ;
Ampanozi, Garyfalia ;
Ebert, Lars ;
Germerott, Tanja ;
Hatch, Gary M. ;
Thali, Michael J. ;
Patak, Michael A. .
EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (10) :2518-2526
[6]
Differentiation of heroin and cocaine using dual-energy CT-an experimental study [J].
Grimm, Jochen ;
Wudy, Ramona ;
Ziegeler, Edvard ;
Wirth, Stefan ;
Uhl, Michael ;
Reiser, Maximilian F. ;
Scherr, Michael .
INTERNATIONAL JOURNAL OF LEGAL MEDICINE, 2014, 128 (03) :475-482
[7]
Drug smuggling by body packing: what radiologists should know about it [J].
Hergan, K ;
Kofler, K ;
Oser, W .
EUROPEAN RADIOLOGY, 2004, 14 (04) :736-742
[8]
Differentiation of cocaine from heroine body packs by computed tomography: Impact of different tube voltages and the dual-energy index [J].
Leschka, Sebastian ;
Fornaro, Juergen ;
Laberke, Patrick ;
Blum, Simon ;
Alkadhi, Hatem ;
Niederer, Ivo ;
Meile, Christian ;
Hibbeln, Dennis ;
Hausmann, Roland ;
Wildermuth, Simon ;
Eisenhart, Daniel .
JOURNAL OF FORENSIC RADIOLOGY AND IMAGING, 2013, 1 (02) :46-50
[9]
Low-Dose Computed Tomography for the Detection of Cocaine Body Packs: Clinical Evaluation and Legal Issues [J].
Pache, G. ;
Einhaus, D. ;
Bulla, S. ;
Baumann, T. ;
Langer, M. ;
Blanke, P. .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2012, 184 (02) :122-129
[10]
Analysis of illicit cocaine and heroin samples seized in Luxembourg from 2005-2010 [J].
Schneider, Serge ;
Meys, Francoise .
FORENSIC SCIENCE INTERNATIONAL, 2011, 212 (1-3) :242-246