Periprosthetic bone resorption - Particles versus movement

被引:122
作者
Aspenberg, P
Herbertsson, P
机构
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 1996年 / 78B卷 / 04期
关键词
D O I
10.1302/0301-620X.78B4.0780641
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Using a rat model, we created a bone-to-titanium interface and applied phagocytosable high-density polyethylene particles between-the bone and implant, either initially or when the interface had matured, No fibrous membrane developed and no bone resorption was found, If sliding movements were initiated at the interface after two weeks, there was formation of a fibrous membrane, The additional application of particles did not change the thickness of the membrane, and there were only minor qualitative changes, Creation of a membrane by movement followed by cessation of movement and the application of particles caused the membrane to persist, whereas in a particle-free control group bone-to-metal contact was re-established, Our findings suggest that mechanical stimuli are of primary importance for prosthetic loosening, and that particles may modulate the later stages of the loosening process.
引用
收藏
页码:641 / 646
页数:6
相关论文
共 10 条
  • [1] INTERMITTENT MICROMOTION INHIBITS BONE INGROWTH - TITANIUM IMPLANTS IN RABBITS
    ASPENBERG, P
    GOODMAN, S
    TOKSVIGLARSEN, S
    RYD, L
    ALBREKTSSON, T
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1992, 63 (02): : 141 - 145
  • [2] EARLY MIGRATION AND LATE ASEPTIC FAILURE OF PROXIMAL FEMORAL PROSTHESES
    FREEMAN, MAR
    PLANTEBORDENEUVE, P
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (03): : 432 - 438
  • [3] IN-VIVO INFLAMMATORY RESPONSE TO POLYMETHYLMETHACRYLATE PARTICULATE DEBRIS - EFFECT OF SIZE, MORPHOLOGY, AND SURFACE-AREA
    GELB, H
    SCHUMACHER, HR
    CUCKLER, J
    BAKER, DG
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 1994, 12 (01) : 83 - 92
  • [4] GOODMAN SB, 1994, ACTA ORTHOP SCAND S, V258, P1
  • [5] A RAT MODEL OF RESORPTION OF BONE AT THE CEMENT-BONE INTERFACE IN THE PRESENCE OF POLYETHYLENE WEAR PARTICLES
    HOWIE, DW
    VERNONROBERTS, B
    OAKESHOTT, R
    MANTHEY, B
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (02) : 257 - 263
  • [6] HOWIE DW, 1993, ORTHOP CLIN N AM, V24, P571
  • [7] DOES EARLY MICROMOTION OF FEMORAL STEM PROSTHESES MATTER - 4-7-YEAR STEREORADIOGRAPHIC FOLLOW-UP OF 84 CEMENTED PROSTHESES
    KARRHOLM, J
    BORSSEN, B
    LOWENHIELM, G
    SNORRASON, F
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (06): : 912 - 917
  • [8] PERIPROSTHETIC OSTEOLYSIS IN TOTAL HIP-ARTHROPLASTY - THE ROLE OF PARTICULATE WEAR DEBRIS
    MALONEY, WJ
    SMITH, RL
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77 (09) : 1448 - 1461
  • [9] ROENTGEN STEREOPHOTOGRAMMETRIC ANALYSIS AS A PREDICTOR OF MECHANICAL LOOSENING OF KNEE PROSTHESES
    RYD, L
    ALBREKTSSON, BEJ
    CARLSSON, L
    DANSGARD, F
    HERBERTS, P
    LINDSTRAND, A
    REGNER, L
    TOKSVIGLARSEN, S
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1995, 77B (03): : 377 - 383
  • [10] PREDICTION OF CLINICAL OUTCOME OF THR FROM MIGRATION MEASUREMENTS ON STANDARD RADIOGRAPHS
    WALKER, PS
    MAI, SF
    COBB, AG
    BENTLEY, G
    HUA, J
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1995, 77 (05): : 705 - 714