In-channel dual-electrode amperometric detection in electrophoretic chips with a palladium film decoupler

被引:26
作者
Lai, CCJ
Chen, CH
Ko, FH [1 ]
机构
[1] Natl Tsing Hua Univ, Dept Chem, Hsinchu 30013, Taiwan
[2] Natl Nano Device Labs, Hsinchu 30050, Taiwan
关键词
palladium film decoupler; dual-electrode detection; chip technology; amperometric detection;
D O I
10.1016/j.chroma.2003.09.053
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An electrophoretic microchip integrated with a Pd-film decoupler and a series-dual electrode was proven practical (200-800V/cm) for routine amperometric detection. In fluidic systems, amperometric enhancement of parallel-opposed dual-electrode detection is due to redox cycling of analytes between the electrodes. We, however, found that the oxidation current of catecholamines was enhanced significantly (1.9-3.8 folds) by switching from the single electrode mode to dual-series mode. This novel finding was unexpected because the unidirectional flow characteristic of the microfluidic system should eliminate the possibility for analytes physically migrating back and forth between the upstream and downstream electrodes. We attribute the enhancement to turbulence generated by impinging of the flow onto the edge of the downstream electrode. The linear range, sensitivity, limit of detection (S/N = 3) and number of theoretical plates for DA and CA are, respectively, 0.5-50 muM. 47 pA/muM, 0.25 muM, 7000 m(-1), and 1.0-100 muM, 28 pA/muM, 0.49 muM, 15 000 m(-1). (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:143 / 150
页数:8
相关论文
共 55 条
[21]   DUAL ELECTROCHEMICAL DETECTION OF CYSTEINE AND CYSTINE IN CAPILLARY ZONE ELECTROPHORESIS [J].
LIN, BL ;
COLON, LA ;
ZARE, RN .
JOURNAL OF CHROMATOGRAPHY A, 1994, 680 (01) :263-270
[22]   Carbon film-based interdigitated array microelectrode used in capillary electrophoresis with electrochemical detection [J].
Liu, ZM ;
Niwa, O ;
Kurita, R ;
Horiuchi, T .
ANALYTICAL CHEMISTRY, 2000, 72 (06) :1315-1321
[23]   Miniaturized thin-layer radial flow cell with interdigitated ring-shaped microarray electrode used as amperometric detector for capillary electrophoresis [J].
Liu, ZM ;
Niwa, O ;
Kurita, R ;
Horiuchi, T .
JOURNAL OF CHROMATOGRAPHY A, 2000, 891 (01) :149-156
[24]   Measurement of electroosmotic flow in plastic imprinted microfluid devices and the effect of protein adsorption on flow rate [J].
Locascio, LE ;
Perso, CE ;
Lee, CS .
JOURNAL OF CHROMATOGRAPHY A, 1999, 857 (1-2) :275-284
[25]  
Lunte S. M., 1996, LAB TECHNIQUES ELECT, P813
[26]   Dual-electrode electrochemical detection for poly(dimethylsiloxane)-fabricated capillary electrophoresis microchips [J].
Martin, RS ;
Gawron, AJ ;
Lunte, SM ;
Henry, CS .
ANALYTICAL CHEMISTRY, 2000, 72 (14) :3196-3202
[27]   In-channel electrochemical detection for microchip capillary electrophoresis using an electrically isolated potentiostat [J].
Martin, RS ;
Ratzlaff, KL ;
Huynh, BH ;
Lunte, SM .
ANALYTICAL CHEMISTRY, 2002, 74 (05) :1136-+
[28]   Carbon paste-based electrochemical detectors for microchip capillary electrophoresis/electrochemistry [J].
Martin, RS ;
Gawron, AJ ;
Fogarty, BA ;
Regan, FB ;
Dempsey, E ;
Lunte, SM .
ANALYST, 2001, 126 (03) :277-280
[29]   Fabrication of plastic microfluid channels by imprinting methods [J].
Martynova, L ;
Locascio, LE ;
Gaitan, M ;
Kramer, GW ;
Christensen, RG ;
MacCrehan, WA .
ANALYTICAL CHEMISTRY, 1997, 69 (23) :4783-4789
[30]  
Matysik FM, 1996, FRESEN J ANAL CHEM, V356, P169