Image-guided otologic surgery

被引:9
作者
Labadie, RF [1 ]
Fenlon, M [1 ]
Cevikalp, H [1 ]
Harris, S [1 ]
Galloway, R [1 ]
Fitzpatrick, JM [1 ]
机构
[1] Vanderbilt Univ, Med Ctr, Med Sci N, Dept Otolaryngol Head & Neck Surg, Nashville, TN 37232 USA
来源
CARS 2003: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS | 2003年 / 1256卷
关键词
image-guided surgery; registration error; fiducial markers; otology; mastoidectomy;
D O I
10.1016/S0531-5131(03)00273-5
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Application of image-guided surgical systems to otologic surgery has been limited by the need for submillimeter accuracy via a fiducial system that is easily useable (i.e. noninvasive and nonobstructive). To overcome these limitations and demonstrate the feasibility of image-guided otologic surgery, a novel fiducial marker system was constructed which attaches to a dental biteblock and has fiducial markers surrounding the surgical field of interest (the ears/temporal bones). Accuracy was tested by fitting the device to a cadaveric skull and embedding targets near anatomically important locations. High-resolution CT scanning (thickness=0.5 mm) was then performed. Marker and target locations were measured in physical space using an infrared, image-acquisition system. These measurements were used in calculating target registration error-the error associated with identification of the surgical targets. This error was minimized when the maximum number of fiducial markers was used (nine fiducials surrounding each ear). Submillimeter target registration error was repeatedly achieved with five markers surrounding the ear of interest and one marker centrally located on the contralateral side. (C) 2003 Published by Elsevier Science B.V.
引用
收藏
页码:627 / 632
页数:6
相关论文
共 8 条
[1]  
COHEN D, 1989, AM J OTOL, V10, P456
[2]   Design and evaluation of a system for microscope-assisted guided interventions (MAGI) [J].
Edwards, PJ ;
King, AP ;
Maurer, CR ;
de Cunha, DA ;
Hawkes, DJ ;
Hill, DLG ;
Gaston, RP ;
Fenlon, MR ;
Jusczyzck, A ;
Strong, AJ ;
Chandler, CL ;
Gleeson, MJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (11) :1082-1093
[3]   Locking acrylic resin dental stent for image-guided surgery [J].
Fenlon, MR ;
Jusczyzck, AS ;
Edwards, PJ ;
King, AP .
JOURNAL OF PROSTHETIC DENTISTRY, 2000, 83 (04) :482-485
[4]   Predicting error in rigid-body point-based registration [J].
Fitzpatrick, JM ;
West, JB ;
Maurer, CR .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (05) :694-702
[5]  
Kemppainen HO, 1999, ACTA OTO-LARYNGOL, V119, P568
[6]   Registration of head CT images to physical space using a weighted combination of points and surfaces [J].
Maurer, CR ;
Maciunas, RJ ;
Fitzpatrick, JM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (05) :753-761
[7]   An automatic technique for finding and localizing externally attached markers in CT and MR volume images of the head [J].
Wang, MY ;
Maurer, CR ;
Fitzpatrick, JM ;
MAciunas, RJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (06) :627-637
[8]   Fiducial point placement and the accuracy of point-based, rigid body registration [J].
West, JB ;
Fitzpatrick, JM ;
Toms, SA ;
Maurer, CR ;
Maciunas, RJ .
NEUROSURGERY, 2001, 48 (04) :810-816