On-column sample enrichment for capillary electrophoresis sheathless electrospray ionization mass spectrometry: Evaluation for peptide analysis and protein identification

被引:57
作者
Janini, GM
Zhou, M
Yu, LR
Blonder, J
Gignac, M
Conrads, TP
Issaq, HJ
Veenstra, TD
机构
[1] NCI, Lab Proteom & Analyt Technol, SAIC Frederick Inc, Frederick, MD 21702 USA
[2] NCI, Image Anal Lab, SAIC Frederick Inc, Frederick, MD 21702 USA
关键词
D O I
10.1021/ac0301548
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Although several designs have been advanced for coupling sample enrichment devices to a sheathless electrospray ionization-mass spectrometry (MS) interface on a capillary electrophoresis (CE) column, most of these approaches suffer from difficulties in fabrication, and the CE separation efficiency is degraded as a result of the presence of coupling sleeves. We have developed a design that offers significant improvements in terms of ease of fabrication, durability, and maintenance of the integrity of the CE-separated analyte zones. Capillaries with different inside and outside diameters were evaluated to optimize the performance of the CE-MS system, resulting in a mass limit of detection of 500 amol for tandem MS analysis of a standard peptide using a 20-mum-i.d. capillary. The improved design incorporates an efficient method to preconcentrate a sample directly within the CE capillary followed by its electrophoretic separation and detection using a true zero dead-volume sheathless CE-MS interface. Testing of this novel CE-MS system showed its ability to characterize proteomic samples such as protein digests, in-gel-digested proteins, and hydrophobic peptides as well as to quantitate ICAT-labeled peptides.
引用
收藏
页码:5984 / 5993
页数:10
相关论文
共 57 条
[1]  
Barroso MB, 1999, J AM SOC MASS SPECTR, V10, P1271
[2]   Enrichment of integral membrane proteins for proteomic analysis using liquid chromatography-tandem mass spectrometry [J].
Blonder, J ;
Goshe, MB ;
Moore, RJ ;
Pasa-Tolic, L ;
Masselon, CD ;
Lipton, MS ;
Smith, RD .
JOURNAL OF PROTEOME RESEARCH, 2002, 1 (04) :351-360
[3]  
BLONDER J, IN PRESS PROTEOMICS
[4]   Analysis of peptides, proteins, protein digests, and whole human blood by capillary electrophoresis electrospray ionization mass spectrometry using an in-capillary electrode sheathless interface [J].
Cao, P ;
Moini, M .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1998, 9 (10) :1081-1088
[5]   Sheathless capillary electrophoresis/electrospray mass spectrometry using a carbon-coated fused silica capillary [J].
Chang, YZ ;
Her, GR .
ANALYTICAL CHEMISTRY, 2000, 72 (03) :626-630
[6]   Precolumn affinity capillary electrophoresis for the identification of clinically relevant proteins in human serum: Application to human cardiac troponin I [J].
Dalluge, JJ ;
Sander, LC .
ANALYTICAL CHEMISTRY, 1998, 70 (24) :5339-5343
[7]   Advances in CE MS [J].
Ding, JM ;
Vouros, P .
ANALYTICAL CHEMISTRY, 1999, 71 (11) :378A-385A
[8]   ONLINE TIME-OF-FLIGHT MASS-SPECTROMETRIC ANALYSIS OF PEPTIDES SEPARATED BY CAPILLARY ELECTROPHORESIS [J].
FANG, LL ;
ZHANG, R ;
WILLIAMS, ER ;
ZARE, RN .
ANALYTICAL CHEMISTRY, 1994, 66 (21) :3696-3701
[9]   Hadamard transform time-of-flight mass spectrometry:: A high-speed detector for capillary-format separations [J].
Fernández, FM ;
Vadillo, JM ;
Kimmel, JR ;
Wetterhall, M ;
Markides, K ;
Rodriguez, N ;
Zare, RN .
ANALYTICAL CHEMISTRY, 2002, 74 (07) :1611-1617
[10]   Protein identification by capillary zone electrophoresis/microelectrospray ionization-tandem mass spectrometry at the subfemtomole level [J].
Figeys, D ;
vanOostveen, I ;
Ducret, A ;
Aebersold, R .
ANALYTICAL CHEMISTRY, 1996, 68 (11) :1822-1828