On-column sample enrichment for capillary electrophoresis sheathless electrospray ionization mass spectrometry: Evaluation for peptide analysis and protein identification

被引:57
作者
Janini, GM
Zhou, M
Yu, LR
Blonder, J
Gignac, M
Conrads, TP
Issaq, HJ
Veenstra, TD
机构
[1] NCI, Lab Proteom & Analyt Technol, SAIC Frederick Inc, Frederick, MD 21702 USA
[2] NCI, Image Anal Lab, SAIC Frederick Inc, Frederick, MD 21702 USA
关键词
D O I
10.1021/ac0301548
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Although several designs have been advanced for coupling sample enrichment devices to a sheathless electrospray ionization-mass spectrometry (MS) interface on a capillary electrophoresis (CE) column, most of these approaches suffer from difficulties in fabrication, and the CE separation efficiency is degraded as a result of the presence of coupling sleeves. We have developed a design that offers significant improvements in terms of ease of fabrication, durability, and maintenance of the integrity of the CE-separated analyte zones. Capillaries with different inside and outside diameters were evaluated to optimize the performance of the CE-MS system, resulting in a mass limit of detection of 500 amol for tandem MS analysis of a standard peptide using a 20-mum-i.d. capillary. The improved design incorporates an efficient method to preconcentrate a sample directly within the CE capillary followed by its electrophoretic separation and detection using a true zero dead-volume sheathless CE-MS interface. Testing of this novel CE-MS system showed its ability to characterize proteomic samples such as protein digests, in-gel-digested proteins, and hydrophobic peptides as well as to quantitate ICAT-labeled peptides.
引用
收藏
页码:5984 / 5993
页数:10
相关论文
共 57 条
[31]   CAPILLARY ELECTROPHORESIS WITH ONLINE SAMPLE PRETREATMENT FOR THE ANALYSIS OF BIOLOGICAL SAMPLES WITH DIRECT-INJECTION [J].
MORITA, I ;
SAWADA, J .
JOURNAL OF CHROMATOGRAPHY, 1993, 641 (02) :375-381
[32]   ONLINE MASS-SPECTROMETRIC DETECTION FOR CAPILLARY ZONE ELECTROPHORESIS [J].
OLIVARES, JA ;
NGUYEN, NT ;
YONKER, CR ;
SMITH, RD .
ANALYTICAL CHEMISTRY, 1987, 59 (08) :1230-1232
[33]  
Osbourn DM, 2000, ELECTROPHORESIS, V21, P2768, DOI 10.1002/1522-2683(20000801)21:14<2768::AID-ELPS2768>3.0.CO
[34]  
2-P
[35]   Miniaturised on-line solid-phase extraction for enhancement of concentration sensitivity in capillary electrophoresis [J].
Petersson, M ;
Wahlund, KG ;
Nilsson, S .
JOURNAL OF CHROMATOGRAPHY A, 1999, 841 (02) :249-261
[36]   New sheathless interface for coupling capillary electrophoresis to electrospray mass spectrometry evaluated by the analysis of fatty acids and prostaglandins [J].
Petersson, MA ;
Hulthe, G ;
Fogelqvist, E .
JOURNAL OF CHROMATOGRAPHY A, 1999, 854 (1-2) :141-154
[37]  
Samskog J, 2000, J MASS SPECTROM, V35, P919, DOI 10.1002/1096-9888(200007)35:7<919::AID-JMS20>3.0.CO
[38]  
2-N
[39]  
Settlage RE, 1998, J MICROCOLUMN SEP, V10, P281, DOI 10.1002/(SICI)1520-667X(1998)10:3<281::AID-MCS7>3.0.CO
[40]  
2-C