On-column sample enrichment for capillary electrophoresis sheathless electrospray ionization mass spectrometry: Evaluation for peptide analysis and protein identification

被引:57
作者
Janini, GM
Zhou, M
Yu, LR
Blonder, J
Gignac, M
Conrads, TP
Issaq, HJ
Veenstra, TD
机构
[1] NCI, Lab Proteom & Analyt Technol, SAIC Frederick Inc, Frederick, MD 21702 USA
[2] NCI, Image Anal Lab, SAIC Frederick Inc, Frederick, MD 21702 USA
关键词
D O I
10.1021/ac0301548
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Although several designs have been advanced for coupling sample enrichment devices to a sheathless electrospray ionization-mass spectrometry (MS) interface on a capillary electrophoresis (CE) column, most of these approaches suffer from difficulties in fabrication, and the CE separation efficiency is degraded as a result of the presence of coupling sleeves. We have developed a design that offers significant improvements in terms of ease of fabrication, durability, and maintenance of the integrity of the CE-separated analyte zones. Capillaries with different inside and outside diameters were evaluated to optimize the performance of the CE-MS system, resulting in a mass limit of detection of 500 amol for tandem MS analysis of a standard peptide using a 20-mum-i.d. capillary. The improved design incorporates an efficient method to preconcentrate a sample directly within the CE capillary followed by its electrophoretic separation and detection using a true zero dead-volume sheathless CE-MS interface. Testing of this novel CE-MS system showed its ability to characterize proteomic samples such as protein digests, in-gel-digested proteins, and hydrophobic peptides as well as to quantitate ICAT-labeled peptides.
引用
收藏
页码:5984 / 5993
页数:10
相关论文
共 57 条
[21]   Capillary zone electrophoresis-electrospray mass spectrometry at submicroliter flow rates: Practical considerations and analytical performance [J].
Kelly, JF ;
Ramaley, L ;
Thibault, P .
ANALYTICAL CHEMISTRY, 1997, 69 (01) :51-60
[22]   DURABLE GOLD-COATED FUSED-SILICA CAPILLARIES FOR USE IN ELECTROSPRAY MASS-SPECTROMETRY [J].
KRIGER, MS ;
COOK, KD ;
RAMSEY, RS .
ANALYTICAL CHEMISTRY, 1995, 67 (02) :385-389
[23]   Development of an on-line preconcentration method for the analysis of pathogenic lipopolysaccharides using capillary electrophoresis - electrospray mass spectrometry - Application to small colony isolates [J].
Li, J ;
Thibault, P ;
Martin, A ;
Richards, JC ;
Wakarchuk, WW ;
van der Wilp, W .
JOURNAL OF CHROMATOGRAPHY A, 1998, 817 (1-2) :325-336
[24]  
Mazereeuw M, 1997, RAPID COMMUN MASS SP, V11, P981
[25]   Polyaniline: A conductive polymer coating for durable nanospray emitters [J].
Maziarz, EP ;
Lorenz, SA ;
White, TP ;
Wood, TD .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2000, 11 (07) :659-663
[26]  
McComb ME, 2000, ELECTROPHORESIS, V21, P1354, DOI 10.1002/(SICI)1522-2683(20000401)21:7<1354::AID-ELPS1354>3.0.CO
[27]  
2-Q
[28]   Design and performance of a universal sheathless capillary electrophoresis to mass spectrometry interface using a split-flow technique [J].
Moini, M .
ANALYTICAL CHEMISTRY, 2001, 73 (14) :3497-3501
[29]   Analysis of carbonic anhydrase in human red blood cells using capillary electrophoresis/electrospray ionization-mass spectrometry [J].
Moini, M ;
Demars, SM ;
Huang, HL .
ANALYTICAL CHEMISTRY, 2002, 74 (15) :3772-3776
[30]   Capillary electrophoresis mass spectrometry and its application to the analysis of biological mixtures [J].
Moini, M .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 373 (06) :466-480