Critical review of the application of liquid chromatography/mass spectrometry to the determination of pesticide residues in biological samples

被引:201
作者
Hernández, F [1 ]
Sancho, JV [1 ]
Pozo, OJ [1 ]
机构
[1] Univ Jaume 1, Res Inst Pesticides & Water, Castellon de La Plana 12071, Spain
关键词
pesticide residues; metabolites; liquid chromatography; mass spectrometry; review; human urine; serum; blood;
D O I
10.1007/s00216-005-3185-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A critical review is made on the use of hyphenated liquid chromatography/mass spectrometry (LC-MS) for the identification and quantification of pesticides and their metabolites in human biosamples (whole blood, plasma, serum and urine). The first applications of LC-MS in this field began in the early 1990s. Since then, increasing interest has been shown in applying this powerful technique, with most applications dealing with the determination of a variety of chemically diverse metabolites in urine. The use of different LC-MS interfaces and mass spectral detection modes are discussed. Special attention is given to tandem mass spectrometry (MS/MS) due to its inherent advantages of increased sensitivity and selectivity, as well as its advantages for identification and confirmation of analytes in samples. Quantification can be severely affected by matrix effects, the most common being inhibition of the ionisation of analytes in the mass spectrometer, which leads to unacceptable errors if no correction is made. Different approaches can be employed to minimise this undesirable matrix effect, the preferred being the use of labelled internal standards (when available) in isotope dilution methods or the application of an efficient clean-up, performed off-line or automated on-line. Adequate criteria for confirming the identities of residues detected are required in order to avoid false positives. The criterion most commonly used with a triple quadrupole instrument is the monitoring of two MS/MS transitions together with the ion abundance ratio. TOF mass analysers are seldom used in pesticide residue analysis despite their improved resolution and mass accuracy characteristics, which makes them very suitable for confirmation purposes. The main reasons for the relative unpopularity of TOF MS in residue analysis are its limited sensitivity and its high acquisition cost. In this paper, we present a critical assessment on current techniques, trends and future developments, and give illustrative examples to point out the main characteristics of LC-MS for pesticide residue analysis in biological fluids.
引用
收藏
页码:934 / 946
页数:13
相关论文
共 50 条
  • [1] The ion suppression phenomenon in liquid chromatography-mass spectrometry and its consequences in the field of residue
    Antignac, JP
    de Wasch, K
    Monteau, F
    De Brabander, H
    Andre, F
    Le Bizec, B
    [J]. ANALYTICA CHIMICA ACTA, 2005, 529 (1-2) : 129 - 136
  • [2] Biological monitoring of pesticide exposure: a review of analytical methods
    Aprea, C
    Colosio, C
    Mammone, T
    Minoia, C
    Maroni, M
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 769 (02): : 191 - 219
  • [3] Isotope dilution high-performance liquid chromatography-tandem mass Spectrometry method for quantifying urinary metabolites of synthetic pyrethroid insecticides
    Baker, SE
    Olsson, AO
    Barr, DB
    [J]. ARCHIVES OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 2004, 46 (03) : 281 - 288
  • [4] Quantification of selected pesticide metabolites in human urine using isotope dilution high-performance liquid chromatography/tandem mass spectrometry
    Baker, SE
    Barr, DB
    Driskell, WJ
    Beeson, MD
    Needham, LL
    [J]. JOURNAL OF EXPOSURE ANALYSIS AND ENVIRONMENTAL EPIDEMIOLOGY, 2000, 10 (06): : 789 - 798
  • [5] Analytical methods for biological monitoring of exposure to pesticides: a review
    Barr, DB
    Needham, LL
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 778 (1-2): : 5 - 29
  • [6] Measurement of p-nitrophenol in the urine of residents whose homes were contaminated with methyl parathion
    Barr, DB
    Turner, WE
    DiPietro, E
    McClure, PC
    Baker, SE
    Barr, JR
    Gehle, K
    Grissom, RE
    Bravo, R
    Driske, WJ
    Patterson, DG
    Hill, RH
    Needham, LL
    Pirkle, JL
    Sampson, EJ
    [J]. ENVIRONMENTAL HEALTH PERSPECTIVES, 2002, 110 : 1085 - 1091
  • [7] Strategies for biological monitoring of exposure for contemporary-use pesticides
    Barr, DB
    Barr, JR
    Driskell, WJ
    Hill, RH
    Ashley, DL
    Needham, LL
    Head, SL
    Sampson, EJ
    [J]. TOXICOLOGY AND INDUSTRIAL HEALTH, 1999, 15 (1-2) : 168 - 179
  • [8] Isotope dilution high-performance liquid chromatography/tandem mass spectrometry method for quantifying urinary metabolites of atrazine, malathion, and 2,4-dichlorophenoxyacetic acid
    Beeson, MD
    Driskell, WJ
    Barr, DB
    [J]. ANALYTICAL CHEMISTRY, 1999, 71 (16) : 3526 - 3530
  • [9] Quantitation of SR 27417 in human plasma using electrospray liquid chromatography tandem mass spectrometry: A study of ion suppression
    Buhrman, DL
    Price, PI
    Rudewicz, PJ
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1996, 7 (11) : 1099 - 1105
  • [10] Practical implications of some recent studies in electrospray ionization fundamentals
    Cech, NB
    Enke, CG
    [J]. MASS SPECTROMETRY REVIEWS, 2001, 20 (06) : 362 - 387