Multimode process monitoring with Bayesian inference-based finite Gaussian mixture models

被引:509
作者
Yu, Jie [1 ]
Qin, S. Joe [2 ,3 ]
机构
[1] Univ Texas Austin, Dept Chem Engn, Austin, TX 78712 USA
[2] Univ So Calif, Mork Family Dept Chem Engn & Mat Sci, Ming Hsie Dept Elect Engn, Los Angeles, CA 90089 USA
[3] Univ So Calif, Daniel J Epstein Dept Ind & Syst Engn, Los Angeles, CA 90089 USA
关键词
multimode process monitoring; fault detection; finite Gaussian mixture model; Bayesian inference; Mahalanobis distance; global probabilistic index; Tennessee Eastman chemical process;
D O I
10.1002/aic.11515
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
For complex industrial processes with multiple operating conditions, the traditional multivariate process monitoring techniques such as principal component analysis (PCA) and partial least squares (PLS) are ill-suited because the fundamental assumption that the operating data follow a unimodal Gaussian distribution usually becomes invalid. In this article, a novel multimode process monitoring approach based on finite Gaussian mixture model (FGMM) and Bayesian inference strategy is proposed. First, the process data are assumed to be from a number of different clusters, each of which corresponds to an operating mode and can be characterized by a Gaussian component. In the absence of a priori process knowledge, the Figueiredo-Jain (F-J) algorithm is then adopted to automatically optimize the number of Gaussian components and estimate their statistical distribution parameters. With the obtained FGMM, a Bayesian inference strategy is further utilized to compute the posterior probabilities of each monitored sample belonging to the multiple components and derive an integrated global probabilistic index for fault detection of multimode processes. The validity and effectiveness of the proposed monitoring approach are illustrated through three examples: (1) a simple multivariate linear system, (2) a simulated continuous stirred tank heater (CSTH) process, and (3) the Tennessee Eastman challenge problem. The comparison of monitoring results demonstrates that the proposed approach is superior to the conventional PCA method and can achieve accurate and early detection of various types of faults in multimode processes. (C) 2008 American Institute of Chemical Engineers.
引用
收藏
页码:1811 / 1829
页数:19
相关论文
共 62 条
[11]   Process monitoring using a Gaussian mixture model via principal component analysis and discriminant analysis [J].
Choi, SW ;
Park, JH ;
Lee, IB .
COMPUTERS & CHEMICAL ENGINEERING, 2004, 28 (08) :1377-1387
[12]   Fault detection and operation mode identification based on pattern classification with variable selection [J].
Chu, YH ;
Qin, SJ ;
Han, CH .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2004, 43 (07) :1701-1710
[13]   A PLANT-WIDE INDUSTRIAL-PROCESS CONTROL PROBLEM [J].
DOWNS, JJ ;
VOGEL, EF .
COMPUTERS & CHEMICAL ENGINEERING, 1993, 17 (03) :245-255
[14]  
Duda RO, 2006, PATTERN CLASSIFICATI
[15]   Identification of faulty sensors using principal component analysis [J].
Dunia, R ;
Qin, SJ ;
Edgar, TF ;
McAvoy, TJ .
AICHE JOURNAL, 1996, 42 (10) :2797-2812
[16]   Unsupervised learning of finite mixture models [J].
Figueiredo, MAT ;
Jain, AK .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 2002, 24 (03) :381-396
[17]   FAULT-DIAGNOSIS IN DYNAMIC-SYSTEMS USING ANALYTICAL AND KNOWLEDGE-BASED REDUNDANCY - A SURVEY AND SOME NEW RESULTS [J].
FRANK, PM .
AUTOMATICA, 1990, 26 (03) :459-474
[18]  
Gertler J. J., 1988, IEEE Control Systems Magazine, V8, P3, DOI 10.1109/37.9163
[19]   A new fault diagnosis method using fault directions in fisher discriminant analysis [J].
He, QP ;
Qin, SJ ;
Wang, J .
AICHE JOURNAL, 2005, 51 (02) :555-571
[20]   Real-time monitoring for a process with multiple operating modes [J].
Hwang, DH ;
Han, CH .
CONTROL ENGINEERING PRACTICE, 1999, 7 (07) :891-902