Comparison of 9 different PCR primers for the rapid detection of severe acute respiratory syndrome coronavirus using 2 RNA extraction methods

被引:11
作者
Chui, L [1 ]
Drebot, M
Andonov, A
Petrich, A
Glushek, M
Mahony, J
机构
[1] Univ Alberta Hosp, Provincial Lab Publ Hlth, Edmonton, AB T6G 2J2, Canada
[2] Natl Microbiol Lab, Winnipeg, MB R3E 3R2, Canada
[3] McMaster Univ, St Josephs Healthcare, Hamilton, ON L8N 4A6, Canada
关键词
SARS-CoV; real-time and conventional RT-PCR; sensitivity and specificity;
D O I
10.1016/j.diagmicrobio.2005.03.007
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
The sensitivity and specificity of various severe acute respiratory syndrome coronavirus (SARS-CoV) PCR primer and probe sets were evaluated through the use of commercial kits and in-house amplification formats. Conventional and real-time PCR assays were performed using a heat-block thermocycler ABI 9600, the Roche LightCycler (TM) version 1.2, or the ABI 7000 Sequence Detection System. The sensitivity of all primers was between 0.0004 and 0.04 PFU with viral cell lysate and between 0.004 and 0.4 PFU in spiked stool specimen per PCR assay. The primer sets for real-time PCR assays were at one least 1 log more sensitive than the primer sets used in the conventional PCR. A panel of viruses including swine gastroenteritis virus, bovine coronavirus, avian bronchitis virus (Connecticut strain), avian bronchitis virus (Massachusetts strain), human coronaviruses 229E and OC43, parainfluenza virus (type III), human metapneumovirus, adenovirus, respiratory syncytial virus, and influenza A were tested by all assays. All real-time PCR assays used probe-based detection, and no cross-reactivity was observed. With conventional PCR, analysis was performed using agarose gel electrophoresis and multiple nonspecific bands were observed. Two commercial extraction methods, magnetic particle capture and silica-based procedure were evaluated and the results were comparable. The former was less laborious with shorter time for completion and can easily be adapted to an automated system such as the MagNa Pure-I-C, which can extract nucleic acid from clinical samples and load it into the sample capillaries of the LightCycler (TM). As exemplified by this study, the continued refinement and evaluation of PCR procedures will greatly benefit the diagnostic laboratory during an outbreak of SARS. (c) 2005 Elsevier Inc. All rights reserved.
引用
收藏
页码:47 / 55
页数:9
相关论文
共 19 条
[1]  
CUSI MG, 1994, BIOTECHNIQUES, V17, P1034
[2]   Evaluation of advanced reverse transcription-PCR assays and an alternative PCR target region for detection of severe acute respiratory syndrome-associated coronavirus [J].
Drosten, C ;
Chiu, LL ;
Panning, M ;
Leong, HN ;
Preiser, W ;
Tam, JS ;
Günther, S ;
Kramme, S ;
Emmerich, P ;
Ng, WL ;
Schmitz, H ;
Koay, ESC .
JOURNAL OF CLINICAL MICROBIOLOGY, 2004, 42 (05) :2043-2047
[3]   Identification of a novel coronavirus in patients with severe acute respiratory syndrome [J].
Drosten, C ;
Günther, S ;
Preiser, W ;
van der Werf, S ;
Brodt, HR ;
Becker, S ;
Rabenau, H ;
Panning, M ;
Kolesnikova, L ;
Fouchier, RAM ;
Berger, A ;
Burguière, AM ;
Cinatl, J ;
Eickmann, M ;
Escriou, N ;
Grywna, K ;
Kramme, S ;
Manuguerra, JC ;
Müller, S ;
Rickerts, V ;
Stürmer, M ;
Vieth, S ;
Klenk, HD ;
Osterhaus, ADME ;
Schmitz, H ;
Doerr, HW .
NEW ENGLAND JOURNAL OF MEDICINE, 2003, 348 (20) :1967-1976
[4]   Real-time reverse transcription-polymerase chain reaction assay for SARS-associated coronavirus [J].
Emery, SL ;
Erdman, DD ;
Bowen, MD ;
Newton, BR ;
Winchell, JM ;
Meyer, RF ;
Tong, SX ;
Cook, BT ;
Holloway, BP ;
McCaustland, KA ;
Rota, PA ;
Bankamp, B ;
Lowe, LE ;
Ksiazek, TG ;
Bellini, WJ ;
Anderson, LJ .
EMERGING INFECTIOUS DISEASES, 2004, 10 (02) :311-316
[5]   Isolation and characterization of viruses related to the SARS coronavirus from animals in Southern China [J].
Guan, Y ;
Zheng, BJ ;
He, YQ ;
Liu, XL ;
Zhuang, ZX ;
Cheung, CL ;
Luo, SW ;
Li, PH ;
Zhang, LJ ;
Guan, YJ ;
Butt, KM ;
Wong, KL ;
Chan, KW ;
Lim, W ;
Shortridge, KF ;
Yuen, KY ;
Peiris, JSM ;
Poon, LLM .
SCIENCE, 2003, 302 (5643) :276-278
[6]   Comparison of two real-time quantitative assays for detection of severe acute respiratory syndrome coronavirus [J].
Hourfar, MK ;
Roth, WK ;
Seifried, E ;
Schmidt, M .
JOURNAL OF CLINICAL MICROBIOLOGY, 2004, 42 (05) :2094-2100
[7]   A novel coronavirus associated with severe acute respiratory syndrome [J].
Ksiazek, TG ;
Erdman, D ;
Goldsmith, CS ;
Zaki, SR ;
Peret, T ;
Emery, S ;
Tong, SX ;
Urbani, C ;
Comer, JA ;
Lim, W ;
Rollin, PE ;
Dowell, SF ;
Ling, AE ;
Humphrey, CD ;
Shieh, WJ ;
Guarner, J ;
Paddock, CD ;
Rota, P ;
Fields, B ;
DeRisi, J ;
Yang, JY ;
Cox, N ;
Hughes, JM ;
LeDuc, JW ;
Bellini, WJ ;
Anderson, LJ .
NEW ENGLAND JOURNAL OF MEDICINE, 2003, 348 (20) :1953-1966
[8]   A major outbreak of severe acute respiratory syndrome in Hong Kong [J].
Lee, N ;
Hui, D ;
Wu, A ;
Chan, P ;
Cameron, P ;
Joynt, GM ;
Ahuja, A ;
Yung, MY ;
Leung, CB ;
To, KF ;
Lui, SF ;
Szeto, CC ;
Chung, S ;
Sung, JJY .
NEW ENGLAND JOURNAL OF MEDICINE, 2003, 348 (20) :1986-1994
[9]  
*NAT CTR INJ PREV, 2003, REP C MILD TRAUM BRA, P1
[10]   Coronavirus as a possible cause of severe acute respiratory syndrome [J].
Peiris, JSM ;
Lai, ST ;
Poon, LLM ;
Guan, Y ;
Yam, LYC ;
Lim, W ;
Nicholls, J ;
Yee, WKS ;
Yan, WW ;
Cheung, MT ;
Cheng, VCC ;
Chan, KH ;
Tsang, DNC ;
Yung, RWH ;
Ng, TK ;
Yuen, KY .
LANCET, 2003, 361 (9366) :1319-1325