Recent advances in sheathless interfacing of capillary electrophoresis and electrospray ionization mass spectrometry

被引:66
作者
Zamfir, Alina D.
机构
[1] Univ Arad, Dept Chem & Biol, RO-310139 Arad, Romania
[2] Natl Inst Res & Dev Electrochem & Condensed Matte, Mass Spectrometry Dept, RO-300224 Timisoara, Romania
关键词
capillary electrophoresis; electrospray mass spectrometry; sheathless interface; microfluidics; review;
D O I
10.1016/j.chroma.2007.03.115
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
On line sheathless capillary electrophoresis (CE)-electrospray ionization (ESI) mass spectrometry is developing as a powerful method in bioanalytics as it provides high resolution, sensitivity, relatively short analysis times, and amenability to a wide class of compounds. However, unlike the popular nano liquid chromatography (nano LC) or sheath-flow CE/ESI-MS, the sheathless coupling lacks standardized designs and protocols. For this reason, sheathless CE/ESI is a subject of conceptual and technical upgrading more than any other liquid-based separation method hyphenated to MS. Here, recent innovations in sheathless CE/ESI-MS interfacing are gathered in a survey covering the 2005/2006 period. In the first part of the review, the current concepts and methods for in-laboratory production of sturdy designs based on either conductive emitters or electrodeless interfaces are described. The second part is dedicated to microchip CE platforms with externally connected emitters for sheathless coupling to ESI-MS and advanced microfluidic devices integrating CE and sheathless electrospray in a single chip substrate. The advantages, limitations and feasibility for certain applications of all these systems as well as the perspectives for their performance improvement are concurrently assessed. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:2 / 13
页数:12
相关论文
共 60 条
[1]   Top-down analysis of basic proteins by microchip capillary electrophoresis mass spectrometry [J].
Akashi, Satoko ;
Suzuki, Koichi ;
Arai, Akihiro ;
Yamada, Naoyuki ;
Suzuki, Ei-Ichiro ;
Hirayama, Kazuo ;
Nakamura, Shin ;
Nishimura, Yoshifumi .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (12) :1932-1938
[2]   Capillary zone electrophoresis of glycopeptides under controlled electroosmotic flow conditions coupled to electrospray and matrix-assisted laser desorption/ionization mass spectrometry [J].
Amon, S ;
Plematl, A ;
Rizzi, A .
ELECTROPHORESIS, 2006, 27 (5-6) :1209-1219
[3]   Glycoprotein characterization combining intact protein and glycan analysis by capillary electrophoresis-electrospray ionization-mass spectrometry [J].
Balaguer, Elvira ;
Neusuess, Christian .
ANALYTICAL CHEMISTRY, 2006, 78 (15) :5384-5393
[4]  
Barnidge DR, 1999, RAPID COMMUN MASS SP, V13, P994, DOI 10.1002/(SICI)1097-0231(19990615)13:11<994::AID-RCM596>3.0.CO
[5]  
2-W
[6]   Fabrication of porous polymer monoliths in polymeric microfluidic chips as an electrospray emitter for direct coupling to mass spectrometry [J].
Bedair, MF ;
Oleschuk, RD .
ANALYTICAL CHEMISTRY, 2006, 78 (04) :1130-1138
[7]   Sheathless reverse-polarity capillary electrophoresis-electrospray-mass spectrometry for analysis of underivatized glycoconjugates [J].
Bindila, L ;
Peter-Katalinic, J ;
Zamfir, A .
ELECTROPHORESIS, 2005, 26 (7-8) :1488-1499
[8]   Overview on advances in capillary electrophoresis-mass spectrometry of carbohydrates: A tabulated review [J].
Campa, Cristiana ;
Coslovi, Anna ;
Flamigni, Anna ;
Rossi, Marco .
ELECTROPHORESIS, 2006, 27 (11) :2027-2050
[9]   Sheathless capillary electrophoresis/electrospray mass spectrometry using a carbon-coated fused silica capillary [J].
Chang, YZ ;
Her, GR .
ANALYTICAL CHEMISTRY, 2000, 72 (03) :626-630
[10]   Sheathless capillary electrophoresis-mass spectrometry using a pulsed electrospray ionization source [J].
Chao, Bing-Fong ;
Chen, Chao-Jung ;
Li, Fu-An ;
Her, Guor-Rong .
ELECTROPHORESIS, 2006, 27 (11) :2083-2090