Reproducibility of Spectral-Domain Optical Coherence Tomography Total Retinal Thickness Measurements in Mice

被引:44
作者
Gabriele, Michelle L. [1 ,2 ,3 ]
Ishikawa, Hiroshi [1 ,2 ]
Schuman, Joel S. [1 ,2 ,3 ]
Bilonick, Richard A. [1 ]
Kim, Jongsick [1 ,2 ]
Kagemann, Larry [1 ,2 ]
Wollstein, Gadi [1 ]
机构
[1] Univ Pittsburgh, Inst Eye & Ear, UPMC Eye Ctr, Ophthalmol & Visual Sci Res Ctr,Dept Ophthalmol, Pittsburgh, PA 15213 USA
[2] Univ Pittsburgh, Swanson Sch Engn, Dept Bioengn, Pittsburgh, PA 15213 USA
[3] Carnegie Mellon Univ, Ctr Neural Basis Cognit, Pittsburgh, PA 15213 USA
基金
美国国家卫生研究院;
关键词
FIBER LAYER THICKNESS; LONGITUDINAL VARIABILITY; GLAUCOMATOUS EYES; RODENT RETINA; MOUSE RETINA; NERVE HEAD; DEGENERATION; MODEL; DISC; OCT;
D O I
10.1167/iovs.10-5662
中图分类号
R77 [眼科学];
学科分类号
100212 [眼科学];
摘要
PURPOSE. To test the reproducibility of spectral-domain optical coherence tomography (SD-OCT) total retinal thickness (TRT) measurements in mice. METHODS. C57Bl/6 mice were anesthetized, and three repeated volumetric images were acquired in both eyes with SD-OCT (250 A-scans x 250 frames x 1024 samplings), centered on the optic nerve head (ONH). The mice were repositioned between scans. TRT was automatically measured within a sampling band of retinal thickness with radii of 55 to 70 pixels, centered on the ONH by using custom segmentation software. The first volumetric image acquired in a given eye was used to register the remaining two SD-OCT images by manually aligning the en face images with respect to rotation and linear translation. Linear mixed-effects models were fitted to global and quadrant thicknesses, taking into account the clustering between eyes, to assess imprecision (measurement reproducibility). RESULTS. Twenty-six eyes of 13 adult mice (age 13 weeks) were imaged. The mean global TRT across all eyes was 298.21 mu m, with a mouse heterogeneity standard deviation (SD) of 4.88 mu m (coefficient of variation [CV] = 0.016), an eye SD of 3.32 mu m (CV = 0.011), and a device-related imprecision SD of 2.33 mu m (CV = 0.008). The superior quadrant had the thickest mean TRT measurement (310.38 mu m) and the highest (worst) imprecision SD (3.13 mu m; CV = 0.010), and the inferior quadrant had the thinnest mean TRT (291.55 mu m). The quadrant with the lowest (best) imprecision SD was in the nasal one (2.06 mu m; CV = 0.007). CONCLUSIONS. Good reproducibility was observed for SD-OCT retinal thickness measurements in mice. SD-OCT may be useful for in vivo longitudinal studies in mice. (Invest Ophthalmol Vis Sci. 2010; 51: 6519-6523) DOI:10.1167/iovs.10-5662
引用
收藏
页码:6519 / 6523
页数:5
相关论文
共 30 条
[1]
[Anonymous], R LANG ENV STAT COMP
[2]
Baumann M, 1998, OPHTHALMIC SURG LAS, V29, P280
[3]
Reproducibility of nerve fiber layer thickness measurements by use of optical coherence tomography [J].
Blumenthal, EZ ;
Williams, JM ;
Weinreb, RN ;
Girkin, CA ;
Berry, CC ;
Zangwill, LM .
OPHTHALMOLOGY, 2000, 107 (12) :2278-2282
[4]
Reproducibility of retinal nerve fiber thickness measurements using the stratus OCT in normal and glaucomatous eyes [J].
Budenz, DL ;
Chang, RT ;
Huang, XR ;
Knighton, RW ;
Tielsch, JM .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (07) :2440-2443
[5]
Reliability of nerve fiber layer thickness measurements using optical coherence tomography in normal and glaucomatous eyes [J].
Carpineto, P ;
Ciancaglini, M ;
Zuppardi, E ;
Falconio, G ;
Doronzo, E ;
Mastropasqua, L .
OPHTHALMOLOGY, 2003, 110 (01) :190-195
[6]
Spectral domain optical coherence tomography in a murine retinal detachment model [J].
Cebulla, Colleen M. ;
Ruggeri, Marco ;
Murray, Timothy G. ;
Feuer, William J. ;
Hernandez, Eleut .
EXPERIMENTAL EYE RESEARCH, 2010, 90 (04) :521-527
[7]
Phase-Contrast OCT Imaging of Transverse Flows in the Mouse Retina and Choroid [J].
Fingler, Jeff ;
Readhead, Carol ;
Schwartz, Daniel M. ;
Fraser, Scott E. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008, 49 (11) :5055-5059
[8]
Noninvasive, In Vivo Assessment of Mouse Retinal Structure Using Optical Coherence Tomography [J].
Fischer, M. Dominik ;
Huber, Gesine ;
Beck, Susanne C. ;
Tanimoto, Naoyuki ;
Muehlfriedel, Regine ;
Fahl, Edda ;
Grimm, Christian ;
Wenzel, Andreas ;
Reme, Charlotte E. ;
van de Pavert, Serge A. ;
Wijnholds, Jan ;
Pacal, Marek ;
Bremner, Rod ;
Seeliger, Mathias W. .
PLOS ONE, 2009, 4 (10)
[9]
Reproducibility of RTVue Retinal Nerve Fiber Layer Thickness and Optic Disc Measurements and Agreement with Stratus Optical Coherence Tomography Measurements [J].
Gonzalez-Garcia, Alberto O. ;
Vizzeri, Gianmarco ;
Bowd, Christopher ;
Medeiros, Felipe A. ;
Zangwill, Linda M. ;
Weinreb, Robert N. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 147 (06) :1067-1074
[10]
Gürses-Özden R, 2004, J GLAUCOMA, V13, P238