Optimization strategies for the analysis and purification of drug discovery compounds by reversed-phase high-performance liquid chromatography with high-pH mobile phases

被引:17
作者
Espada, A [1 ]
Marín, A [1 ]
Anta, C [1 ]
机构
[1] DCRT Alcobendas, European Analyt Technol, Lilly SA, Alcobendas 28108, Spain
关键词
optimization; mobile phase composition; preparative chromatography; pharmaceutical analysis; drugs; ammonium hydrogencarbonate;
D O I
10.1016/j.chroma.2003.12.027
中图分类号
Q5 [生物化学];
学科分类号
071010 [生物化学与分子生物学]; 081704 [应用化学];
摘要
Careful selection of both high-pH mobile phase as well as organic modifier, was performed in order to develop and optimize HPLC conditions for the separation of drug discovery compounds. High-pH mobile phases provide excellent chromatographic resolution and increased mass loading of basic compounds. The analytical methods so defined have been successfully transferred to preparative automated UV-directed purification, an important fact due to the increasing number of samples requiring purification. It should be noted that, the single prerequisite for this approach is an analytical LC-UV-MS run, therefore the system has the ability to collect only fractions likely to contain the target product. A cost-effective strategy for maximizing the purification of drug discovery compounds is proposed. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:43 / 51
页数:9
相关论文
共 22 条
[1]
Hit and lead generation:: Beyond high-throughput screening [J].
Bleicher, KH ;
Böhm, HJ ;
Müller, K ;
Alanine, AI .
NATURE REVIEWS DRUG DISCOVERY, 2003, 2 (05) :369-378
[2]
Two-pump at-column-dilution configuration for preparative liquid chromatography-mass spectrometry [J].
Blom, KF .
JOURNAL OF COMBINATORIAL CHEMISTRY, 2002, 4 (04) :295-301
[3]
Overloading study of bases using polymeric RP-HPLC columns as an aid to rationalization of overloading on silica-ODS phases [J].
Buckenmaier, SMC ;
McCalley, DV ;
Euerby, MR .
ANALYTICAL CHEMISTRY, 2002, 74 (18) :4672-4681
[4]
Retention of ionizable compounds on HPLC.: 4.: Mobile-phase pH measurement in methanol/water [J].
Canals, I ;
Portal, JA ;
Bosch, E ;
Rosés, M .
ANALYTICAL CHEMISTRY, 2000, 72 (08) :1802-1809
[5]
Retention of ionizable compounds on HPLC.: 8.: Influence of mobile-phase pH change on the chromatographic retention of acids and bases during gradient elution [J].
Canals, I ;
Valkó, K ;
Bosch, E ;
Hill, AP ;
Rosés, M .
ANALYTICAL CHEMISTRY, 2001, 73 (20) :4937-4945
[6]
STEREOCHEMICAL ANALYSIS OF BETAMETHASONE AND DEXAMETHASONE BY DERIVATIZATION AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
CHEN, SH ;
WU, SM ;
WU, HL .
JOURNAL OF CHROMATOGRAPHY, 1992, 595 (1-2) :203-208
[7]
CLAESSENS HA, 1994, LC GC N AM, V12, P114
[8]
CORENS D, 2002, LC GC EUR, V11, P2
[9]
Ammonium hydrogencarbonate, an excellent buffer for the analysis of basic drugs by liquid chromatography-mass spectrometry at high pH [J].
Espada, A ;
Rivera-Sagredo, A .
JOURNAL OF CHROMATOGRAPHY A, 2003, 987 (1-2) :211-220
[10]
Retention of ionizable compounds in high-performance liquid chromatography IX.: Modelling retention in reversed-phase liquid chromatography as a function of pH and solvent composition with acetonitrile-water mobile phases [J].
Espinosa, S ;
Bosch, E ;
Rosés, M .
JOURNAL OF CHROMATOGRAPHY A, 2002, 947 (01) :47-58