Heterodyne swept-source optical coherence tomography for complete complex conjugate ambiguity removal

被引:2
作者
Maheshwari, A [1 ]
Choma, MA [1 ]
Izatt, JA [1 ]
机构
[1] Duke Univ, Dept Biomed Engn, Durham, NC 27708 USA
来源
Coherence Domain Optical Methods and Optical Coherence Tomography in Biomedicine IX | 2005年 / 5690卷
关键词
optical coherence tomography; Fourier-domain; heterodyne; complex conjugate ambiguity removal;
D O I
10.1117/12.592867
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Fourier domain techniques have increasingly gained attention in the optical coherence tomography field. This is mainly due to demonstrated sensitivities of two to three orders of magnitude greater than conventional time domain techniques. FDOCT images are plagued with two sources of ambiguity and artifact. First, complex conjugate ambiguity arises from the Fourier transform of the real-valued interferometric signal. This ambiguity causes a superposition of reflectors at positive and negative pathlength differences between the sample and reference reflectors. Secondly, the source spectral shape and sample autocorrelation terms appear at DC, there by obscuring reflectors at zero pathlength difference. In this paper, we show that heterodyne detection in swept-source OCT (SSOCT) allows for the resolution of complex conjugate ambiguity and the removal of spectral and autocorrelation artifacts. We show that frequency shifting of the reference arm optical field, by use of acousto-optic modulators, upshifts the cross-interferometric signal to a user-tunable electronic frequency that corresponds to a adjustable electronic pathlength mismatch between the interferometer arms. This electronic pathlength mismatching recenters the A-scan at an offset that can be far from DC, which effectively resolves the complex conjugate ambiguity problem. Additionally, spectral and autocorrelation terms still reside near DC, which allows them to be removed by high-pass filtering. We also show that complex conjugate ambiguity resolution via frequency shifting is immune to falloff induced by finite source linewidth in SSOCT.
引用
收藏
页码:91 / 95
页数:5
相关论文
共 9 条
[1]  
CHOMA, IN PRESS J BIOMED OP
[2]  
CHOMA, 2004, P SPIE SAN JOS CA
[3]   Instantaneous quadrature low-coherence interferometry with 3 x 3 fiber-optic couplers [J].
Choma, MA ;
Yang, CH ;
Izatt, JA .
OPTICS LETTERS, 2003, 28 (22) :2162-2164
[4]   Sensitivity advantage of swept source and Fourier domain optical coherence tomography [J].
Choma, MA ;
Sarunic, MV ;
Yang, CH ;
Izatt, JA .
OPTICS EXPRESS, 2003, 11 (18) :2183-2189
[5]   Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography [J].
de Boer, JF ;
Cense, B ;
Park, BH ;
Pierce, MC ;
Tearney, GJ ;
Bouma, BE .
OPTICS LETTERS, 2003, 28 (21) :2067-2069
[6]   Performance of fourier domain vs. time domain optical coherence tomography [J].
Leitgeb, R ;
Hitzenberger, CK ;
Fercher, AF .
OPTICS EXPRESS, 2003, 11 (08) :889-894
[7]  
SARUNIC, 2004, P SPIE SAN JOS CA
[8]   Full range complex spectral optical coherence tomography technique in eye imaging [J].
Wojtkowski, M ;
Kowalczyk, A ;
Leitgeb, R ;
Fercher, AF .
OPTICS LETTERS, 2002, 27 (16) :1415-1417
[9]   High-speed spectral-domain optical coherence tomography at 1.3 μm wavelength [J].
Yun, SH ;
Tearney, GJ ;
Bouma, BE ;
Park, BH ;
de Boer, JF .
OPTICS EXPRESS, 2003, 11 (26) :3598-3604