Simultaneous height and adhesion imaging of antibody-antigen interactions by atomic force microscopy

被引:151
作者
Willemsen, OH
Snel, MME
van der Werf, KO
de Grooth, BG
Greve, J
Hinterdorfer, P
Gruber, HJ
Schindler, H
van Kooyk, Y
Figdor, CG [1 ]
机构
[1] Univ Nijmegen Hosp, Dept Tumor Immunol, NL-6525 EX Nijmegen, Netherlands
[2] Univ Twente, Dept Appl Phys, Appl Opt Grp, NL-7500 AE Enschede, Netherlands
[3] Univ Linz, Inst Biophys, A-4040 Linz, Austria
关键词
D O I
10.1016/S0006-3495(98)77666-0
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Specific molecular recognition events, detected by atomic force microscopy (AFM), so far lack the detailed topographical information that is usually observed in AFM. We have modified our AFM such that, in combination with a recently developed method to measure antibody-antigen recognition on the single molecular level (Hinterdorfer, P., W. Baumgartner, H. J. Gruber, K. Schilcher, and H. Schindler, Proc. Natl. Acad. Sci. USA 93:3477-3481 (1996)), it allows imaging of a submonolayer of intercellular adhesion molecule-1 (ICAM-1) in adhesion mode. We demonstrate that for the first time the resolution of the topographical image in adhesion mode is only limited by tip convolution and thus comparable to tapping mode images. This is demonstrated by imaging of individual ICAM-1 antigens in both the tapping mode and the adhesion mode. The contrast in the adhesion image that was measured simultaneously with the topography is caused by recognition between individual antibody-antigen pairs. By comparing the high-resolution height image with the adhesion image, it is possible to show that specific molecular recognition is highly correlated with topography. The stability of the improved microscope enabled imaging with forces as low as 100 pN and ultrafast scan speed of 22 force curves per second. The analysis of force curves showed that reproducible unbinding events on subsequent scan lines could be measured.
引用
收藏
页码:2220 / 2228
页数:9
相关论文
共 45 条
  • [1] Detection of antigen-antibody binding events with the atomic force microscope
    Allen, S
    Chen, XY
    Davies, J
    Davies, MC
    Dawkes, AC
    Edwards, JC
    Roberts, CJ
    Sefton, J
    Tendler, SJB
    Williams, PM
    [J]. BIOCHEMISTRY, 1997, 36 (24) : 7457 - 7463
  • [2] FUNCTIONAL-GROUP IMAGING BY ADHESION AFM APPLIED TO LIPID MONOLAYERS
    BERGER, CEH
    VANDERWERF, KO
    KOOYMAN, RPH
    DEGROOTH, BG
    GREVE, J
    [J]. LANGMUIR, 1995, 11 (11) : 4188 - 4192
  • [3] ATOMIC FORCE MICROSCOPE
    BINNIG, G
    QUATE, CF
    GERBER, C
    [J]. PHYSICAL REVIEW LETTERS, 1986, 56 (09) : 930 - 933
  • [4] 7X7 RECONSTRUCTION ON SI(111) RESOLVED IN REAL SPACE
    BINNIG, G
    ROHRER, H
    GERBER, C
    WEIBEL, E
    [J]. PHYSICAL REVIEW LETTERS, 1983, 50 (02) : 120 - 123
  • [5] MULTIPLE ICAM-1 (CD54) EPITOPES ARE INVOLVED IN HOMOTYPIC B-CELL ADHESION
    BLOEMEN, P
    MOLDENHAUER, G
    VANDIJK, M
    SCHUURMAN, HJ
    BLOEM, AC
    [J]. SCANDINAVIAN JOURNAL OF IMMUNOLOGY, 1992, 35 (05) : 517 - 523
  • [6] CALCULATION OF THERMAL NOISE IN ATOMIC-FORCE MICROSCOPY
    BUTT, HJ
    JASCHKE, M
    [J]. NANOTECHNOLOGY, 1995, 6 (01) : 1 - 7
  • [7] BINDING STRENGTH BETWEEN CELL-ADHESION PROTEOGLYCANS MEASURED BY ATOMIC-FORCE MICROSCOPY
    DAMMER, U
    POPESCU, O
    WAGNER, P
    ANSELMETTI, D
    GUNTHERODT, HJ
    MISEVIC, GN
    [J]. SCIENCE, 1995, 267 (5201) : 1173 - 1175
  • [8] Specific antigen/antibody interactions measured by force microscopy
    Dammer, U
    Hegner, M
    Anselmetti, D
    Wagner, P
    Dreier, M
    Huber, W
    Guntherodt, HJ
    [J]. BIOPHYSICAL JOURNAL, 1996, 70 (05) : 2437 - 2441
  • [9] DEGROOTH BG, 1992, J MICROSC-OXFORD, V168, P239, DOI 10.1111/j.1365-2818.1992.tb03266.x
  • [10] THE DYNAMIC REGULATION OF INTEGRIN ADHESIVENESS
    DIAMOND, MS
    SPRINGER, TA
    [J]. CURRENT BIOLOGY, 1994, 4 (06) : 506 - 517