摘要
Single component equilibrium isotherms of six compounds (aniline, caffeine, ethylbenzene, phenol, propranolol, and theophylline) were determined by the inverse method on 10 Kromasil-C-18 columns, using water-methanol solutions as the mobile phase. This method offers an economic and fast isotherm determination by means of the overloaded band profiles of the compounds. Five out of the ten columns used in this test come from the same batch whilst the other five columns represent five additional batches. Statistical evaluation was used to assess the reproducibility of the isotherm parameters. We found that the column-to-column reproducibility of the isotherm parameters is of the same magnitude as the batch-to-batch reproducibility (with the exception of one outlier column). In most of the cases, the reproducibilities of the saturation capacities and that of the retention factors are excellent, they are typically between 1.2 and 3%, and very often below 2%. Within the limits of the experimental precision, these results agree with those obtained earlier, using a conventional method of isotherm determination. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:21 / 38
页数:18
相关论文
共 23 条
[1]   Comparison between adsorption isotherm determination techniques and overloaded band profiles on four batches of monolithic columns [J].
Cavazzini, A ;
Felinger, A ;
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1012 (02) :139-149
[2]   DETERMINATION OF ISOTHERMS FROM CHROMATOGRAPHIC PEAK SHAPES [J].
DOSE, EV ;
JACOBSON, S ;
GUIOCHON, G .
ANALYTICAL CHEMISTRY, 1991, 63 (08) :833-839
[3]   Identification of the factors that influence the reproducibility of chromatographic retention data [J].
Felinger, A ;
Kele, M ;
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 2001, 913 (1-2) :23-48
[4]   Determination of the single component and competitive adsorption isotherms of the 1-indanol enantiomers by the inverse method [J].
Felinger, A ;
Zhou, DM ;
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1005 (1-2) :35-49
[5]   Numerical determination of the competitive isotherm of enantiomers [J].
Felinger, A ;
Cavazzini, A ;
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 2003, 986 (02) :207-225
[6]  
Felinger A., 1998, DATA ANAL SIGNAL PRO
[7]   Repeatability and reproducibility of high concentration data in reversed-phase liquid chromatography I.: Overloaded band profiles on Kromasil-C18 [J].
Gritti, F ;
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1003 (1-2) :43-72
[8]   Comparison of the adsorption equilibrium of a few low-molecular mass compounds on a monolithic and a packed column in reversed-phase liquid chromatography [J].
Gritti, F ;
Piatkowski, W ;
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 2002, 978 (1-2) :81-107
[9]  
Guiochon G, 1999, INT S NUM M, V129, P423
[10]  
Guiochon G., 1994, FUNDAMENTALS PREPARA