Rate-independent characteristics of an arthroscopically implantable force probe in the human Achilles tendon

被引:13
作者
Hall, GW
Crandall, JR
Carmines, DV
Hale, JE
机构
[1] Univ Virginia, Automobile Safety Lab, Charlottesville, VA 22902 USA
[2] Univ Virginia, Dept Orthopaed, Charlottesville, VA 22908 USA
关键词
implant; force; transducer; tendon; calibration;
D O I
10.1016/S0021-9290(98)00167-5
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The effect of loading rate on specimen calibration was investigated for an implantable force sensor of the two-point loading variety. This variety of sensor incorporates a strain gage to measure the compressive load applied to the sensor due Co tensile loading in a soft tissue specimen. The Achilles tendon in each of four human cadaveric lower extremities was instrumented with a force sensor and then loaded in tension using a materials testing machine. Each specimen was tensile tested at three different displacement rates, 0.25, 2.5 and 12.7 cm s(-1), corresponding with mean loading rates of 33.8, 513.2, and 2838.6 N s(-1), respectively. A calibration curve relating the force sensor signal and applied tendon tension was generated for each specimen/displacement rate combination. For each specimen, calibration curves were compared by calculating an RMS error for the entire data set (e(RMS) = 1.6% of the full load value) and a coefficient of determination, R-2, of a curve fit through all of the data (R-2 = 99.6%). Over the range of rates tested, no measurable change in sensor sensitivity due to loading rate was observed. Hysteresis for all displacement rates was on the order of 2.4%. (C) 1999 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:203 / 207
页数:5
相关论文
共 7 条
[1]  
FLEMING B, 1996, P 42 ORS C ATL GEORG, P75
[2]   IN-VITRO EVALUATION OF AN IMPLANTABLE FORCE TRANSDUCER (IFT) IN A PATELLAR TENDON MODEL [J].
GLOS, DL ;
BUTLER, DL ;
GROOD, ES ;
LEVY, MS .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1993, 115 (04) :335-343
[3]   Evaluation of the implantable force transducer for chronic tendon-force recordings [J].
Herzog, W ;
Archambault, JM ;
Leonard, TR ;
Nguyen, HK .
JOURNAL OF BIOMECHANICS, 1996, 29 (01) :103-109
[4]   In-situ calibration of the implantable force transducer [J].
Herzog, W ;
Hasler, EM ;
Leonard, TR .
JOURNAL OF BIOMECHANICS, 1996, 29 (12) :1649-1652
[5]   The use of an implantable force transducer to measure patellar tendon forces in goats - Comment [J].
Herzog, W ;
Hasler, EM .
JOURNAL OF BIOMECHANICS, 1997, 30 (03) :303-303
[6]  
ROBERTS C, 1994, P 40 ORS C NEW ORL L, P84
[7]  
XU W, 1992, J BIOMECHANICAL ENG, V114, P171