CT-guided percutaneous core biopsies of pulmonary lesions -: Diagnostic accuracy, complications and therapeutic impact

被引:27
作者
Hänninen, EL [1 ]
Vogl, TJ [1 ]
Ricke, J [1 ]
Felix, R [1 ]
机构
[1] Humboldt Univ, Chaite Med Ctr, Dept Radiol, Campus Virchow Clin, Berlin, Germany
关键词
thorax; lung; pulmonary lesion; CT-guided intervention; biopsy;
D O I
10.1034/j.1600-0455.2001.042002151.x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose. To evaluate the diagnostic accuracy, complications, and therapeutic impact of CT-guided percutaneous core biopsies of pulmonary lesions. Material and Methods. Seventy-nine patients underwent diagnostic CT-guided percutaneous core biopsies of pulmonary lesions between July 1995 and March 1999. Evaluation included corresponding clinical data, pathologic results, and therapeutic consequences. Results: There were 29 benign and 50 malignant lesions. Percutaneous core biopsy had an overall diagnostic accuracy of 95%. For malignant lesions, core biopsy was positive in 48 patients (sensitivity 96%), and for benign lesions, in 27 (sensitivity 93%). There were no false-positive findings. Pneumothoraces were observed in 19 patients (24%) and 4 of them required a chest drain (5%). There were no hematothoraces or major bleeding complications; however, postinterventional local hemorrhages were observed in 23 patients (29%). No hemoptysis was noted. Conclusion. Percutaneous core biopsies of pulmonary lesions offer excellent diagnostic accuracy for both benign and malignant pulmonary lesions at a low complication rate.
引用
收藏
页码:151 / 155
页数:5
相关论文
共 25 条
[11]  
Lee SI, 1996, RADIOLOGY, V201, P764
[12]   Solitary pulmonary nodule - Treatment options [J].
Liptay, MJ .
CHEST, 1999, 116 (06) :517S-518S
[13]  
LOHELA P, 1994, ACTA RADIOL, V35, P251
[14]   Intrapulmonary lesions: Percutaneous automated biopsy with a detachable, 18-gauge, coaxial cutting needle [J].
Lucidarme, O ;
Howarth, N ;
Finet, JF ;
Grenier, PA .
RADIOLOGY, 1998, 207 (03) :759-765
[15]   Should cutting needles replace needle aspiration of lung lesions? [J].
McLoud, TC .
RADIOLOGY, 1998, 207 (03) :569-570
[16]   Percutaneous needle-aspiration lung biopsy: Is it really necessary in all patients with a focal lung opacity? [J].
Morcos, SK ;
Anderson, PB .
RADIOLOGY, 1999, 211 (02) :590-591
[17]   COAXIAL PERCUTANEOUS BIOPSY TECHNIQUE WITH AUTOMATED BIOPSY DEVICES - VALUE IN IMPROVING ACCURACY AND NEGATIVE PREDICTIVE VALUE [J].
MOULTON, JS ;
MOORE, PT .
RADIOLOGY, 1993, 186 (02) :515-522
[18]  
Pisani P, 1999, INT J CANCER, V83, P18, DOI 10.1002/(SICI)1097-0215(19990924)83:1&lt
[19]  
18::AID-IJC5&gt
[20]  
3.0.CO