Nodule detection in digital chest radiography:: Summary of the radius chest trial

被引:57
作者
Håkansson, M [1 ]
Båth, M
Börjesson, S
Kheddache, S
Grahn, A
Ruschin, M
Tingberg, A
Mattsson, S
Månsson, LG
机构
[1] Sahlgrenska Univ Hosp, Dept Med Phys & Biomed Engn, SE-41345 Gothenburg, Sweden
[2] Sahlgrenska Univ Hosp, Dept Radiol, SE-41345 Gothenburg, Sweden
[3] Malmo Univ Hosp, Dept Med Radiat Phys, SE-20502 Malmo, Sweden
关键词
D O I
10.1093/rpd/nch574
中图分类号
X [环境科学、安全科学];
学科分类号
08 [工学]; 0830 [环境科学与工程];
摘要
As a part of the Europe-wide research project 'Unification of physical and clinical requirements for medical X-ray imaging'-governed by the Radiological Imaging Unification Strategies (RADIUS) Group-a major image quality trial was conducted by members of the group. The RADIUS chest trial aimed at thoroughly examining various aspects of nodule detection in digital chest radiography, such as the effects of nodule location, system noise, anatomical noise, and anatomical background. The main findings of the RADIUS chest trial concerning the detection of a lung nodule with a size in the order of 10 mm can be summarised as: (1) the detectability of the nodule is largely dependent on its location in the chest. (2) the system noise has a minor impact on the detectability at the dose levels used today, (3) the disturbance of the anatomical noise is larger than that of the system noise but smaller than that of the anatomical background and (4) the anatomical background acts as noise to a large extent and is the major image component affecting the detectability of the nodule.
引用
收藏
页码:114 / 120
页数:7
相关论文
共 7 条
[1]
Nodule detection in digital chest radiography:: Part of image background acting as pure noise [J].
Båth, M ;
Håkansson, M ;
Börjesson, S ;
Kheddache, S ;
Grahn, A ;
Bochud, FO ;
Verdun, FR ;
Månsson, LG .
RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) :102-108
[2]
Nodule detection in digital chest radiography:: Introduction to the radius chest trial [J].
Båth, M ;
Håkansson, M ;
Börjesson, S ;
Kheddache, S ;
Grahn, A ;
Ruschin, M ;
Tingberg, A ;
Mattsson, S ;
Månsson, LG .
RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) :85-91
[3]
Nodule detection in digital chest radiography:: Effect of anatomical noise [J].
Båth, M ;
Håkansson, M ;
Börjesson, S ;
Hoeschen, C ;
Tischenko, O ;
Kheddache, S ;
Vikgren, J ;
Månsson, LG .
RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) :109-113
[4]
Nodule detection in digital chest radiography:: Effect of system noise [J].
Håkansson, M ;
Båth, M ;
Börjesson, S ;
Kheddache, S ;
Johnsson, ÅA ;
Månsson, LG .
RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) :97-101
[5]
Nodule detection in digital chest radiography:: Effect of nodule location [J].
Håkansson, M ;
Båth, M ;
Börjesson, S ;
Kheddache, S ;
Flinck, A ;
Ullman, G ;
Månsson, LG .
RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) :92-96
[6]
SAMEI E, 2000, HDB MED IMAGING, V1, P665
[7]
Reduction of anatomical noise in medical X-ray images [J].
Tischenko, O ;
Hoeschen, C ;
Buhr, E .
RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) :69-74