Accuracy of intravascular ultrasound for diameter measurement of phantom arteries

被引:7
作者
Cooper, BZ [1 ]
Kirwin, JD [1 ]
Panetta, TF [1 ]
Weinreb, FM [1 ]
Ramirez, JA [1 ]
Najjar, JG [1 ]
Blattman, SB [1 ]
Rodino, W [1 ]
Song, M [1 ]
机构
[1] Suny Downstate Med Ctr, Dept Surg, Div Vasc Surg, Brooklyn, NY 11203 USA
关键词
D O I
10.1006/jsre.2001.6214
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background. Uniplanar quantitative angiography (QA) is the standard method for measuring vessel diameter during surgical and endovascular procedures. Intravascular ultrasound (IVUS), a relatively new technology, is another means of obtaining this measurement. This study was designed to validate the accuracy of these two modalities by comparing each to direct caliper measurement, the gold standard, using phantom femoral artery segments (PAS). Materials and methods. PAS diameter was measured with a 12.5-MHz mechanically rotating IVUS catheter (Boston Scientific Corp.) and QA (OEC Corp.) was compared to the direct caliper measurement (Mitutoyo Corp.) at 60 different locations within PAS. At each location minimal lumen diameter and perpendicular lumen diameter were measured and their mean was calculated. The intraclass correlation coefficients (ICCC) between direct caliper measurement and IVUS and uniplanar and biplanar angiography were calculated. Fisher's Z transformation was used to compare the correlation coefficients. Results. The ICCC for IVUS was 0.89. The ICCCs for uniplanar and biplanar angiography were 0.73 and 0.82, respectively. IVUS correlated more closely with direct caliper measurement than uniplanar and biplanar angiography (P = 0.00008, 0.02) Biplanar angiography correlated more closely with direct caliper measurement than uniplanar angiography (P = 0.04). Conclusions. IVUS more accurately measures lumen diameter than uniplanar or biplanar angiography. Diameter measurement with biplanar angiography is more accurate than uniplanar angiography. (C) 2001 Academic Press.
引用
收藏
页码:99 / 105
页数:7
相关论文
共 32 条
[1]
Long-term follow-up after percutaneous transluminal coronary angioplasty was not performed based on intravascular ultrasound findings - Importance of lumen dimensions [J].
Abizaid, AS ;
Mintz, GS ;
Mehran, R ;
Abizaid, A ;
Lansky, AJ ;
Pichard, AD ;
Satler, LF ;
Wu, HS ;
Pappas, C ;
Kent, KM ;
Leon, MB .
CIRCULATION, 1999, 100 (03) :256-261
[2]
Comparison of immediate and intermediate-term results of intravascular ultrasound versus angiography-guided Palmaz-Schatz stent implantation in matched lesions [J].
Albiero, R ;
Rau, T ;
Schluter, M ;
DiMario, C ;
Reimers, B ;
Mathey, DG ;
Tobis, JM ;
Schofer, J ;
Colombo, A .
CIRCULATION, 1997, 96 (09) :2997-3005
[3]
Blasini R, 1997, CATHETER CARDIO DIAG, V42, P113, DOI 10.1002/(SICI)1097-0304(199710)42:2<113::AID-CCD2>3.0.CO
[4]
2-G
[5]
INTRAVASCULAR ULTRASOUND VERSUS ANGIOGRAPHY FOR MEASUREMENT OD LUMINAL DIAMETERS IN NORMAL AND DISEASED CORONARY-ARTERIES [J].
DESCHEERDER, I ;
DEMAN, F ;
HERREGODS, MC ;
WILCZEK, K ;
BARRIOS, L ;
RAYMENANTS, E ;
DESMET, W ;
DEGEEST, H ;
PIESSENS, J .
AMERICAN HEART JOURNAL, 1994, 127 (02) :243-251
[6]
ARTERIAL-WALL CHARACTERISTICS DETERMINED BY INTRAVASCULAR ULTRASOUND IMAGING - AN INVITRO STUDY [J].
GUSSENHOVEN, EJ ;
ESSED, CE ;
LANCEE, CT ;
MASTIK, F ;
FRIETMAN, P ;
VANEGMOND, FC ;
REIBER, J ;
BOSCH, H ;
VANURK, H ;
ROELANDT, J ;
BOM, N .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (04) :947-952
[7]
Comparison of quantitative coronary angiography, intravascular ultrasound, and coronary pressure measurement to assess optimum stent deployment [J].
Hanekamp, CEE ;
Koolen, JJ ;
Pijls, NHJ ;
Michels, HR ;
Bonnier, HJRM .
CIRCULATION, 1999, 99 (08) :1015-1021
[8]
Overestimation of acute lumen gain and late lumen loss by quantitative coronary angiography (compared with intravascular ultrasound) in stented lesions [J].
Hoffmann, R ;
Mintz, GS ;
Popma, JJ ;
Satler, LF ;
Kent, KM ;
Pichard, AD ;
Leon, MB .
AMERICAN JOURNAL OF CARDIOLOGY, 1997, 80 (10) :1277-1281
[9]
Limitations of intravascular ultrasound for the evaluation of coronary luminal area - Comparison with quantitative angiography [J].
Iwami, T ;
Fujii, T ;
Miura, T ;
Otani, N ;
Matsuzaki, M .
JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1996, 60 (08) :575-584
[10]
Validation of the in vivo intravascular ultrasound measurement of in-stent neointimal hyperplasia volumes [J].
Mehran, R ;
Mintz, GS ;
Hong, MK ;
Tio, FO ;
Bramwell, O ;
Brahimi, A ;
Kent, KM ;
Pichard, AD ;
Satler, LF ;
Popma, JJ ;
Leon, MB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (03) :794-799