Automatic detection of detached and erroneous electrodes in electrical impedance tomography

被引:27
作者
Asfaw, Y [1 ]
Adler, A [1 ]
机构
[1] Univ Ottawa, SITE, Ottawa, ON, Canada
关键词
electrical impedance tomography; image reconstruction; data errors; electrodes;
D O I
10.1088/0967-3334/26/2/017
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
One unfortunate occurrence in experimental measurements with electrical impedance tomography is electrodes which become detached or poorly connected, such that the measured data cannot be used. This paper presents an automatic approach to detect such erroneous electrodes. It is based on the assumption that all valid measurements are related by the image reconstruction model, while the measurements from erroneous electrodes are unrelated. The method estimates the data at an electrode based on the measurements from all other electrodes, and compares it to the measurements. If these data match adequately, the set of electrodes does not contain an erroneous electrode. In order to detect an erroneous electrode amongst N electrodes, all sets of N - 1 electrodes are tested, and the set with the best match between measurements and estimate is identified as the one which excludes the erroneous electrode. The method was tested on simulated and experimental data and showed consistent identification of erroneous electrodes with those made by experts.
引用
收藏
页码:S175 / S183
页数:9
相关论文
共 8 条
[1]   Accounting for erroneous electrode data in electrical impedance tomography [J].
Adler, A .
PHYSIOLOGICAL MEASUREMENT, 2004, 25 (01) :227-238
[2]   Electrical impedance tomography: Regularized imaging and contrast detection [J].
Adler, A ;
Guardo, R .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1996, 15 (02) :170-179
[3]   Patient-instrument connection errors in bioelectrical impedance measurement [J].
Al-Hatib, F .
PHYSIOLOGICAL MEASUREMENT, 1998, 19 (02) :285-296
[4]   Electrical impedance tomography with compensation for electrode positioning variations [J].
Blott, BH ;
Daniell, GJ ;
Meeson, S .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (06) :1731-1739
[5]  
EYIIBOGLU BM, 1996, PHYSIOL MEAS, V17, pA59
[6]  
Korzhenevskii AV, 1997, INSTRUM EXP TECH+, V40, P415
[7]   ERRORS IN PROLONGED ELECTRICAL-IMPEDANCE MEASUREMENTS DUE TO ELECTRODE REPOSITIONING AND POSTURAL CHANGES [J].
LOZANO, A ;
ROSELL, J ;
PALLASARENY, R .
PHYSIOLOGICAL MEASUREMENT, 1995, 16 (02) :121-130
[8]   EIT data noise evaluation in the clinical environment [J].
Meeson, S ;
Blott, BH ;
Killingback, ALT .
PHYSIOLOGICAL MEASUREMENT, 1996, 17 :A33-A38