Development of an accurate, sensitive, and robust isotope dilution laser ablation ICP-MS method for simultaneous multi-element analysis (chlorine, sulfur, and heavy metals) in coal samples

被引:48
作者
Boulyga, Sergei F.
Heilmann, Jens
Prohaska, Thomas
Heumann, Klaus G.
机构
[1] Univ Nat Resources & Appl Life Sci, Dept Chem, Div Analyt Chem, VIRIS Lab, A-1190 Vienna, Austria
[2] Univ Mainz, Inst Inorgan Chem & Analyt Chem, D-55099 Mainz, Germany
基金
奥地利科学基金会;
关键词
laser ablation; ICP-MS; coal; metals; sulfur; chlorine;
D O I
10.1007/s00216-007-1485-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method for the direct multi- element determination of Cl, S, Hg, Pb, Cd, U, Br, Cr, Cu, Fe, and Zn in powdered coal samples has been developed by applying inductively coupled plasma isotope dilution mass spectrometry ( ICP- IDMS) with laser- assisted introduction into the plasma. A sector- field ICP- MS with a mass resolution of 4,000 and a high- ablation rate laser ablation system provided significantly better sensitivity, detection limits, and accuracy compared to a conventional laser ablation system coupled with a quadrupole ICP- MS. The sensitivity ranges from about 590 cps for Cl-35(+) to more than 6 x 10(5) cps for U-238(+) for 1 mu g of trace element per gram of coal sample. Detection limits vary from 450 ng g(-1) for chlorine and 18 ng g(-1) for sulfur to 9.5 pg g(-1) for mercury and 0.3 pg g(-1) for uranium. Analyses of minor and trace elements in four certified reference materials ( BCR- 180 Gas Coal, BCR- 331 Steam Coal, SRM 1632c Trace Elements in Coal, SRM 1635 Trace Elements in Coal) yielded good agreement of usually not more than 5% deviation from the certified values and precisions of less than 10% relative standard deviation for most elements. Higher relative standard deviations were found for particular elements such as Hg and Cd caused by inhomogeneities due to associations of these elements within micro- inclusions in coal which was demonstrated for Hg in SRM 1635, SRM 1632c, and another standard reference material ( SRM 2682b, Sulfur and Mercury in Coal). The developed LA- ICP-IDMS method with its simple sample pretreatment opens the possibility for accurate, fast, and highly sensitive determinations of environmentally critical contaminants in coal as well as of trace impurities in similar sample materials like graphite powder and activated charcoal on a routine basis.
引用
收藏
页码:697 / 706
页数:10
相关论文
共 24 条
[1]  
[Anonymous], 1988, INORGANIC MASS SPECT
[2]  
BECKER JS, 1997, J ANAL CHEM+, V359, P338
[3]   The determination of low level trace elements in coals by laser ablation-inductively coupled plasma-mass spectrometry [J].
Booth, CA ;
Spears, DA ;
Krause, P ;
Cox, AG .
FUEL, 1999, 78 (14) :1665-1670
[4]  
Borges D. L.G., 2006, MICROCHIM ACTA, V154, P101
[5]   Direct determination of halogens in powdered geological and environmental samples using isotope dilution laser ablation ICP-MS [J].
Boulyga, SF ;
Heumann, KG .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2005, 242 (2-3) :291-296
[6]   Application of isotope-dilution laser ablation ICP-MS for direct determination of Pu concentrations in soils at pg g-1 levels [J].
Boulyga, SF ;
Tibi, M ;
Heumann, KG .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (02) :342-347
[7]   SPATIAL-DISTRIBUTION OF RADIONUCLIDES IN SOIL AROUND A COAL-FIRED POWER-PLANT - PB-210, PO-210, RA-210, TH-232, K-40 EMITTED WITH THE FLY-ASH AND CS-137 FROM THE WORLDWIDE WEAPON TESTING FALLOUT [J].
BUNZL, K ;
HOTZL, H ;
ROSNER, G ;
WINKLER, R .
SCIENCE OF THE TOTAL ENVIRONMENT, 1984, 38 (SEP) :15-31
[8]   Multielemental laser-enhanced ionization spectrometry for the determination of lead at the trace level in pelletized coal using laser ablation and internal standard signal normalization [J].
Gravel, JFY ;
Viger, ML ;
Nobert, P ;
Boudreau, D .
APPLIED SPECTROSCOPY, 2004, 58 (06) :727-733
[9]   Enhanced sensitivity in laser ablation-ICP mass spectrometry using helium-argon mixtures as aerosol carrier -: Plenary lecture [J].
Günther, D ;
Heinrich, CA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (09) :1363-1368
[10]   A closed system digestion and purification procedure for the accurate assay of chlorine in fossil fuels [J].
Howard, ME ;
Vocke, RD .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (11) :1423-1427