Biomedical soft contact-lens sensor for in situ ocular biomonitoring of tear contents

被引:58
作者
Chu, MingXing [2 ]
Shirai, Takayuki [3 ]
Takahashi, Daishi [1 ]
Arakawa, Takahiro [1 ]
Kudo, Hiroyuki [1 ]
Sano, Kenji [4 ]
Sawada, Shin-ichi [5 ]
Yano, Kazuyoshi [3 ]
Iwasaki, Yasuhiko [6 ]
Akiyoshi, Kazunari [5 ]
Mochizuki, Manabu [4 ]
Mitsubayashi, Kohji [1 ,2 ]
机构
[1] Tokyo Med & Dent Univ, Dept Biomed Devices & Instrumentat, Inst Biomat & Bioengn, Chiyoda Ku, Tokyo 1010062, Japan
[2] Tokyo Med & Dent Univ, Grad Sch Med & Dent Sci, Dept Adv Sci & Technol Biomed Sensors, Bunkyo Ku, Tokyo 1138549, Japan
[3] Tokyo Univ Technol, Grad Sch Bion, Tokyo 1920982, Japan
[4] Tokyo Med & Dent Univ, Dept Ophthalmol & Visual Sci, Bunkyo Ku, Tokyo 1318519, Japan
[5] Tokyo Med & Dent Univ, Dept Organ Mat, Inst Biomat & Bioengn, Chiyoda Ku, Tokyo 1010062, Japan
[6] Kansai Univ, Dept Chem & Mat Engn, Fac Chem Mat & Bioengn, Suita, Osaka 5648680, Japan
基金
日本科学技术振兴机构; 日本学术振兴会;
关键词
Contact-lens; Biosensor; Non-invasive; Ocular biomonitoring; Glucose; EPIDERMAL-GROWTH-FACTOR; RHEUMATOID-ARTHRITIS; SJOGRENS-SYNDROME; GLUCOSE; FLUID; CONJUNCTIVA; ELECTRONICS; ANESTHESIA; BIOSENSOR; DISEASE;
D O I
10.1007/s10544-011-9530-x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A soft contact-lens biosensor (SCL-biosensor) for novel non-invasive biomonitoring of tear fluids was fabricated and tested. Wearing a biosensor on eye enabled the in situ monitoring of tear contents. The biosensor has an enzyme immobilized electrode on the surface of a polydimethyl siloxane (PDMS) contact lens. The SCL-biosensor was fabricated using microfabrication techniques for functional polymers (PDMS and 2-methacryloyloxyethyl phosphorylcholine (MPC) polymer). In investigation of in vitro characterization, the SCL-biosensor showed excellent relationship between the output current and glucose concentration from 0.03 to 5.0 mmol center dot L-1, with a correlation coefficient of 0.994. The calibration range covered the reported tear glucose concentrations (0.14 mmol center dot L-1). Based on the result, ocular biomonitoring with the SCL-biosensor was carried out. The SCL-biosensor well worked both in the static state and the dynamic state. The tear glucose level of rabbit was estimated to 0.12 mmol center dot L-1 at first and then the tear turnover was successfully calculated to be 29.6 A +/- 8.42% min(-1). The result indicated that SCL-biosensor is useful for advanced biomonitoring on eye.
引用
收藏
页码:603 / 611
页数:9
相关论文
共 43 条
[1]   Photonic crystal glucose-sensing material for noninvasive monitoring of glucose in tear fluid [J].
Alexeev, VL ;
Das, S ;
Finegold, DN ;
Asher, SA .
CLINICAL CHEMISTRY, 2004, 50 (12) :2353-2360
[2]   LYSOZYME CONTENT OF TEARS IN PATIENTS WITH SJOGRENS SYNDROME AND RHEUMATOID-ARTHRITIS [J].
AVISAR, R ;
MENACHE, R ;
SHAKED, P ;
RUBINSTEIN, J ;
MACHTEY, I ;
SAVIR, H .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1979, 87 (02) :148-151
[3]   Ascorbic acid levels in human tears after photorefractive keratectomy, transepithelial photorefractive keratectomy, and laser in situ keratomileusis [J].
Bilgihan, A ;
Bilgihan, K ;
Toklu, Y ;
Konuk, O ;
Yis, Ö ;
Hasanreisoglu, B .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (04) :585-588
[4]  
Choy CKM, 2000, INVEST OPHTH VIS SCI, V41, P3293
[5]  
DAUM KM, 1982, INVEST OPHTH VIS SCI, V22, P509
[6]  
DAUM KM, 1984, ACTA OPHTHALMOL, V62, P472
[7]  
Farris R L, 1986, Trans Am Ophthalmol Soc, V84, P250
[8]  
Farris R L, 1985, Trans Am Ophthalmol Soc, V83, P501
[9]   CONCENTRATION OF GLUCOSE AND TOTAL CHLORIDE IN TEARS [J].
GIARDINI, A ;
ROBERTS, JRE .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1950, 34 (12) :737-743
[10]   High-conductivity elastomeric electronics [J].
Gray, DS ;
Tien, J ;
Chen, CS .
ADVANCED MATERIALS, 2004, 16 (05) :393-+