Spiral multislice computed tomography coronary angiography: A current status report

被引:13
作者
De Feyter, P. J.
Meijboom, W. B.
Weustink, A.
Van Mieghem, C.
Mollet, N. R. A.
Vourvouri, E.
Nieman, K.
Cademartiri, F.
机构
[1] Univ Rotterdam Hosp, Dept Cardiol, NL-3000 CA Rotterdam, Netherlands
[2] Univ Rotterdam Hosp, Dept Radiol, Rotterdam, Netherlands
关键词
computed tomography; coronary artery disease; coronary angiography;
D O I
10.1002/clc.16
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Multislice computed tomography coronary angiography (MSCT-CA) has emerged as a powerful noninvasive diagnostic modality to visualize the coronary arteries and to detect significant coronary stenoses. The latest generation 64-slice computed tomography (CT) scanners is a robust technique which allows high-resolution, isotropic, nearly motion-free coronary imaging. Coronary stenoses are detected with high sensitivity and a normal scan accurately rules out the presence of a coronary stenosis. With the introduction of further novel concepts in CT-technology one may expect that MSCT-CA will become a clinically used diagnostic tool.
引用
收藏
页码:437 / 442
页数:6
相关论文
共 21 条
[1]   Contrast-enhanced coronary artery visualization by dual-source computed tomography - Initial experience [J].
Achenbach, S ;
Ropers, D ;
Kuettner, A ;
Flohr, T ;
Ohnesorge, B ;
Bruder, H ;
Theessen, H ;
Karakaya, M ;
Daniel, WG ;
Bautz, W ;
Kalender, WA ;
Anders, K .
EUROPEAN JOURNAL OF RADIOLOGY, 2006, 57 (03) :331-335
[2]   Coronary artery bypass graft (CABG) patency: Assessment with high-resolution submillimeter 16-slice multidetector-row computed tomography (MDCT) versus coronary angiography [J].
Anders, K ;
Baum, U ;
Schmid, M ;
Ropers, D ;
Schmid, A ;
Pohle, K ;
Daniel, WG ;
Bautz, W ;
Achenbach, S .
EUROPEAN JOURNAL OF RADIOLOGY, 2006, 57 (03) :336-344
[3]  
Becker CR, 2000, RADIOLOGE, V40, P118, DOI 10.1007/s001170050019
[4]   Follow-up of coronary artery bypass graft patency by multislice computed tomography [J].
Chiurlia, E ;
Menozzi, M ;
Ratti, C ;
Romagnoli, R ;
Modena, MG .
AMERICAN JOURNAL OF CARDIOLOGY, 2005, 95 (09) :1094-1097
[5]   First performance evaluation of a dual-source CT (DSCT) system [J].
Flohr, TG ;
McCollough, CH ;
Bruder, H ;
Petersilka, M ;
Gruber, K ;
Süss, C ;
Grasruck, M ;
Stierstorfer, K ;
Krauss, B ;
Raupach, R ;
Primak, AN ;
Küttner, A ;
Achenbach, S ;
Becker, C ;
Kopp, A ;
Ohnesorge, BM .
EUROPEAN RADIOLOGY, 2006, 16 (02) :256-268
[6]   Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation [J].
Jakobs, TF ;
Becker, CR ;
Ohnesorge, B ;
Flohr, T ;
Suess, C ;
Schoepf, UJ ;
Reiser, MF .
EUROPEAN RADIOLOGY, 2002, 12 (05) :1081-1086
[7]   Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography - A comparative study with quantitative coronary angiography and intravascular ultrasound [J].
Leber, AW ;
Knez, A ;
von Ziegler, F ;
Becker, A ;
Nikolaou, K ;
Paul, S ;
Wintersperger, B ;
Reiser, M ;
Becker, CR ;
Steinbeck, G ;
Boekstegers, P .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (01) :147-154
[8]   Accuracy of MSCT coronary angiography with 64-slice technology:: first experience [J].
Leschka, S ;
Alkadhi, H ;
Plass, A ;
Desbiolles, L ;
Grünenfelder, J ;
Marincek, B ;
Wildermuth, S .
EUROPEAN HEART JOURNAL, 2005, 26 (15) :1482-1487
[9]  
Martin K, 2004, ACTA PSYCHIAT SCAND, V110, P20
[10]   High-resolution spiral computed tomography coronary angiography in patients referred for diagnostic conventional coronary angiography [J].
Mollet, NR ;
Cademartiri, F ;
van Mieghem, CAG ;
Runza, G ;
McFadden, EP ;
Baks, T ;
Serruys, PW ;
Krestin, GP ;
de Feyter, PJ .
CIRCULATION, 2005, 112 (15) :2318-2323