Accuracy of MSCT coronary angiography with 64-slice technology:: first experience

被引:733
作者
Leschka, S
Alkadhi, H
Plass, A
Desbiolles, L
Grünenfelder, J
Marincek, B
Wildermuth, S
机构
[1] Univ Zurich Hosp, Inst Diagnost Radiol, Dept Med Radiol, CH-8091 Zurich, Switzerland
[2] Univ Zurich Hosp, Cardiovasc Surg Clin, Zurich, Switzerland
关键词
computed tomography; conventional coronary angiography; coronary artery disease;
D O I
10.1093/eurheartj/ehi261
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims The aim of our study was to investigate the accuracy of 64-slice computed tomography (CT) for assessing haemodynamically significant stenoses of coronary arteries, Methods and results CT angiography was performed in 67 patients (50 mate, 17 female; mean age 60.1 +/- 10.5 years) with suspected coronary artery disease and compared with invasive coronary angiography. All vessels >= 1.5 mm were considered for the assessment of significant coronary artery stenosis (diameter reduction >50%). Forty-seven patients were identified as having significant coronary stenoses on invasive angiography with 18% (176/1005) affected segments. None of the coronary segments needed to be excluded from analysis. CT correctly identified all 20 patients having no significant stenosis on invasive angiography. Overall sensitivity for classifying stenoses was 94%, specificity was 97%, positive predictive value was 87%, and negative predictive value was 99%. Conclusion Sixty-four-slice CT provides a high diagnostic accuracy in assessing coronary artery stenoses.
引用
收藏
页码:1482 / 1487
页数:6
相关论文
共 19 条
[1]  
Achenbach S, 2000, CIRCULATION, V102, P2823
[2]  
Achenbach S, 2001, CIRCULATION, V103, P2535
[3]  
Austen W G, 1975, Circulation, V51, P5
[4]   Detection of coronary artery stenoses with multislice helical CT angiography [J].
Becker, CR ;
Knez, A ;
Leber, A ;
Treede, H ;
Ohnesorge, B ;
Schoepf, UJ ;
Reiser, MF .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2002, 26 (05) :750-755
[5]   A COEFFICIENT OF AGREEMENT FOR NOMINAL SCALES [J].
COHEN, J .
EDUCATIONAL AND PSYCHOLOGICAL MEASUREMENT, 1960, 20 (01) :37-46
[6]   Performance evaluation of a 64-slice CT system with z-flying focal spot [J].
Flohr, T ;
Stierstorfer, K ;
Raupach, R ;
Ulzheimer, S ;
Bruder, H .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (12) :1803-1810
[7]   Dose reduction in CT examination of children by an attenuation-based on-line modulation of tube current (CARE Dose) [J].
Greess, H ;
Nömayr, A ;
Wolf, H ;
Baum, U ;
Lell, M ;
Böwing, B ;
Kalender, W ;
Bautz, WA .
EUROPEAN RADIOLOGY, 2002, 12 (06) :1571-1576
[8]   Electron-beam tomography coronary artery calcium and cardiac events - A 37-month follow-up of 5635 initially asymptomatic low- to intermediate-risk adults [J].
Kondos, GT ;
Hoff, JA ;
Sevrukov, A ;
Daviglus, ML ;
Garside, DB ;
Devries, SS ;
Chomka, EV ;
Liu, K .
CIRCULATION, 2003, 107 (20) :2571-2576
[9]   Non-invasive coronary angiography with high resolution multidetector-row computed tomography - Results in 102 patients [J].
Kopp, AF ;
Schroeder, S ;
Kuettner, A ;
Baumbach, A ;
Georg, C ;
Kuzo, R ;
Heuschmid, M ;
Ohnesorge, B ;
Karsch, KR ;
Claussen, CD .
EUROPEAN HEART JOURNAL, 2002, 23 (21) :1714-1725
[10]   MEASUREMENT OF OBSERVER AGREEMENT FOR CATEGORICAL DATA [J].
LANDIS, JR ;
KOCH, GG .
BIOMETRICS, 1977, 33 (01) :159-174