Composite prostheses used to repair abdominal wall defects:: Physical or chemical adhesion barriers?

被引:25
作者
Bellón, JM
Serrano, N
Rodríguez, M
García-Honduvilla, N
Pascual, G
Buján, J
机构
[1] Univ Alcala de Henares, Fac Med, Dept Surg, Madrid 28871, Spain
[2] Univ Alcala de Henares, Fac Med, Dept Med Specialties, Madrid 28871, Spain
关键词
adhesion; composite; soft tissue; prosthesis; wound healing;
D O I
10.1002/jbm.b.30248
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In a composite prosthesis, the component placed at the peritoneal interface takes the form of a physical or chemical barrier. In this experimental study performed on the white New Zealand rabbit, several composites were examined to establish the effectiveness of these barriers at impeding adhesion formation. The biomaterials tested were two polypropylene prostheses (PP) with the physical barriers of expanded polytetrafluoroethylene or pollyurethane (PP + ePTFE and PP + PU) and two prostheses (one polyester and the other PP) with the absorbable chemical barriers of polyethylene glycol/glycerol and hyaluronate, respectively (PO + gl and PP + by). The composites were used to repair 7 X 5 cm defects created in the abdominal wall of the animals by placing the implant in contact with the visceral peritoneum and the subcutaneous tissue and fixing it to recipient tissue by 4/0 polypropylene running suture. Fourteen days after surgery the animals were sacrificed and specimens were taken for light microscopy and scanning electron microscopy. Adhesions developing at the prosthesis/visceral peritoneal interface were quantified. All the prostheses induced optimal mesothelialization. Composites with physical barriers behaved similarly in terms of provoking adhesions. However, the prostheses with chemical barriers differed in their effectiveness at preventing adhesions. Overall, the best results were obtained with the PP + PU composite. (c) 2005 Wiley Periodicals, Inc.
引用
收藏
页码:718 / 724
页数:7
相关论文
共 22 条
[1]   Effects of physical barriers in prevention of adhesions: An incisional hernia model in rats [J].
Alponat, A ;
Lakshminarasappa, SR ;
Teh, M ;
Rajnakova, A ;
Moochhala, S ;
Goh, PMY ;
Chan, STF .
JOURNAL OF SURGICAL RESEARCH, 1997, 68 (02) :126-132
[2]   EXPERIMENTAL EVALUATION OF A NEW COMPOSITE MESH WITH THE SELECTIVE PROPERTY OF INCORPORATION TO THE ABDOMINAL-WALL WITHOUT ADHERING TO THE INTESTINES [J].
AMID, PK ;
SHULMAN, AG ;
LICHTENSTEIN, IL ;
SOSTRIN, S ;
YOUNG, J ;
HAKAKHA, M .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1994, 28 (03) :373-375
[3]   Seprafilm reduces adhesions to polypropylene mesh [J].
Baptista, ML ;
Bonsack, ME ;
Delaney, NP .
SURGERY, 2000, 128 (01) :86-92
[4]  
Bellon JM, 1996, J AM COLL SURGEONS, V183, P11
[5]   INTEGRATION OF BIOMATERIALS IMPLANTED INTO ABDOMINAL-WALL - PROCESS OF SCAR FORMATION AND MACROPHAGE RESPONSE [J].
BELLON, JM ;
BUJAN, J ;
CONTRERAS, L ;
HERNANDO, A .
BIOMATERIALS, 1995, 16 (05) :381-387
[6]   The structure of a biomaterial rather than its chemical composition modulates the repair process at the peritoneal level [J].
Bellón, JM ;
Jurado, F ;
García-Honduvilla, N ;
López, R ;
Carrera-San Martín, A ;
Buján, J .
AMERICAN JOURNAL OF SURGERY, 2002, 184 (02) :154-159
[7]   Evaluation of a new composite prosthesis (PL-PU99) for the repair of abdominal wall defects in terms of behavior at the peritoneal interface [J].
Bellón, JM ;
García-Carranza, A ;
Jurado, F ;
García-Honduvilla, N ;
Carrera-San Martín, A ;
Buján, J .
WORLD JOURNAL OF SURGERY, 2002, 26 (06) :661-666
[8]   Effect of phosphatidylcholine on the process of peritoneal adhesion following implantation of a polypropylene mesh prosthesis [J].
Bellon, JM ;
Contreras, LA ;
Bujan, J ;
Jurado, F .
BIOMATERIALS, 1996, 17 (14) :1369-1372
[9]  
Bellón JM, 1999, EUR J SURG, V165, P145
[10]   Enterocutaneous fistula 14 years after prosthetic mesh repair of a ventral incisional hernia: A life-long risk? [J].
Chew, DKW ;
Choi, LH ;
Rogers, AM .
SURGERY, 2000, 127 (03) :352-353