Accuracy of the Actiheart for the assessment of energy expenditure in adults

被引:157
作者
Crouter, S. E. [1 ]
Churilla, J. R. [1 ]
Bassett, D. R., Jr. [1 ]
机构
[1] Univ Tennessee, Dept Exercise Sport & Leisure Studies, Knoxville, TN USA
关键词
motion sensor; physical activity; oxygen consumption; heart rate;
D O I
10.1038/sj.ejcn.1602766
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Background/Objective: The Actiheart (Mini Mitter, Sunriver, OR, USA) uses heart rate (HR) and activity data to predict activity energy expenditure (AEE). Currently, the Actiheart has only been tested during laboratory conditions. Therefore, the objective of this study was to validate the Actiheart prediction method against indirect calorimetry during a wide range of activities in a field setting. Subjects/Methods: Forty-eight participants (age: 35 +/- 11.4 years) were recruited for the study. Eighteen activities were split into three routines of six activities and each routine was performed by 20 participants. During each routine, the participants wore an Actiheart and simultaneously, AEE was measured with a Cosmed K4b(2) portable metabolic system. The manufacturer's HR algorithm, activity algorithm, and combined activity and HR algorithm were used to estimate AEE. Results: The mean error (and 95% prediction intervals) for the combined activity and HR algorithm, HR algorithm, and activity algorithm versus the Cosmed K4b(2) were 0.02 kJ kg(-1) min(-1) (-0.17, 0.22 kJ kg(-1) min(-1)), -0.03 kJ kg(-1) min(-1) (-0.24, 0.18 kJ kg(-1) min(-1)), and 0.14 kJ kg(-1) min(-1) (-0.12, 0.40 kJ kg(-1) min(-1)), respectively. Conclusion: The Actiheart combined activity and HR algorithm and HR algorithm provide similar estimates of AEE on both a group and individual basis.
引用
收藏
页码:704 / 711
页数:8
相关论文
共 31 条
[1]   Validity of four motion sensors in measuring moderate intensity physical activity [J].
Bassett, DR ;
Ainsworth, BE ;
Swartz, AM ;
Strath, SJ ;
O'Brien, WL ;
King, GA .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2000, 32 (09) :S471-S480
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   Reliability and validity of the combined heart rate and movement sensor Actiheart [J].
Brage, S ;
Brage, N ;
Franks, PW ;
Ekelund, U ;
Wareham, NJ .
EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2005, 59 (04) :561-570
[4]   Branched equation modeling of simultaneous accelerometry and heart rate monitoring improves estimate of directly measured physical activity energy expenditure [J].
Brage, S ;
Brage, N ;
Franks, PW ;
Ekelund, U ;
Wong, MY ;
Andersen, LB ;
Froberg, K ;
Wareham, NJ .
JOURNAL OF APPLIED PHYSIOLOGY, 2004, 96 (01) :343-351
[5]  
*CAMBR NEUR LTD, 2004, ACT US MAN V 3 04
[6]   Comparison of PAEE from combined and separate heart rate and movement models in children [J].
Corder, K ;
Brage, S ;
Wareham, NJ ;
Ekelund, U .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2005, 37 (10) :1761-1767
[7]   Estimating energy expenditure using accelerometers [J].
Crouter, Scott E. ;
Churilla, James R. ;
Bassett, David R., Jr. .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2006, 98 (06) :601-612
[8]   A novel method for using accelerometer data to predict energy expenditure [J].
Crouter, SE ;
Clowers, KG ;
Bassett, DR .
JOURNAL OF APPLIED PHYSIOLOGY, 2006, 100 (04) :1324-1331
[9]   Calibration of the Computer Science and Applications, Inc. accelerometer [J].
Freedson, PS ;
Melanson, E ;
Sirard, J .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1998, 30 (05) :777-781
[10]   SIMULTANEOUS MEASUREMENT OF HEART-RATE AND BODY MOTION TO QUANTITATE PHYSICAL-ACTIVITY [J].
HASKELL, WL ;
YEE, MC ;
EVANS, A ;
IRBY, PJ .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1993, 25 (01) :109-115