Quantification and predictors of prostate position variability in 50 patients evaluated with multiple CT scans during conformal radiotherapy

被引:194
作者
Zelefsky, MJ
Crean, D
Mageras, GS
Lyass, O
Happersett, L
Ling, CC
Leibel, SA
Fuks, Z
Bull, S
Kooy, HM
van Herk, M
Kutcher, GJ
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Radiat Oncol, New York, NY 10021 USA
[2] Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY 10021 USA
[3] Harvard Univ, Sch Med, Joint Ctr Radiat Therapy, Boston, MA 02115 USA
[4] Netherlands Canc Inst, Amsterdam, Netherlands
[5] Univ Ziekenhvizen, Dept Radiotherapy, B-3000 Louvain, Belgium
关键词
prostate motion; CT scans; systematic errors;
D O I
10.1016/S0167-8140(99)00011-0
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To determine the extent and predictors for prostatic motion in a large number of patients evaluated with multiple CT scans during radiotherapy, and evaluate the implications of these data on the design of appropriate treatment margins for patients receiving high-dose three-dimensional conformal radiotherapy. Materials and methods: Fifty patients underwent four serial computerized tomography (CT) scans, consisting of an initial planning scan and subsequent scans at the beginning, middle, and end of the treatment course. Each scan was performed with the patient in the prone treatment position within an immobilization device used during therapy. Contours of the prostate and seminal vesicles were drawn on the axial CT slices of each scan, and the scans were matched by alignment of the pelvic bones with a chamfer matching algorithm. Using the contour information, distributions of the displacement of the organ center of mass and organ border from the planning position were determined separately for the prostate and seminal vesicles in each of the three principle directions: anterior-posterior (AP), superior-inferior (SI) and left-right (LR). Each distribution was fitted to a normal (Gaussian) distribution to determine confidence limits in the center of mass and border displacements and thereby evaluate for the optimal margins needed to contain target motion. Results: The most common directions of displacement of the prostate center of mass (COM) were in the AP and SI directions and were significantly larger than any LR movement. The mean prostate COM displacement ( +/- 1 standard deviation, SD) for the entire population was -1.2 +/- 2.9 mm, -0.5 +/- 3.3 mm and -0.6 +/- 0.8 mm in the, AP and SI and LR directions respectively (negative values indicate posterior, inferior or left displacement). The mean ( +/- 1 SD) seminal vesicle COM displacement for the entire population was -1.4 +/- 4.9 mm, 1.3 +/- 5.5 mm and -0.8 +/- 3.1 mm in the AP and SI and LR directions, respectively. The data indicate a tendency for the population towards posterior displacements of the prostate from the planning position and both posterior and superior displacements of the seminal vesicles. AP movement of both the prostate and seminal vesicles were correlated with changes in rectal volume (P = 0.0014 and < 0.0001, respectively) more than with changes in bladder volume (P = 0.030 for seminal vesicles and 0.19 for prostate). A logistic regression analysis identified the combination of rectal volume > 60 cm(3) and bladder volumes > 40 cm(3) as the only predictor of large ( > 3 mm) systematic deviations for the prostate and seminal vesicles (P = 0.05) defined for each patient as the difference between organ position in the planning scan and mean position as calculated from the three subsequent scans. Conclusions: Prostatic displacement during a course of radiotherapy is more pronounced among patients with initial planning scans with large rectal and bladder volumes. Such patients may require more generous margins around the CTV to assure its enclosure within the prescription dose region. Identification and correction of patients with large systematic errors will minimize the extent of the margin required and decrease the volume of normal tissue exposed to higher radiation doses. (C) 1999 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:225 / 234
页数:10
相关论文
共 27 条
[1]  
[Anonymous], 1993, 50 ICRU
[2]   MEASUREMENT OF PROSTATE MOVEMENT OVER THE COURSE OF ROUTINE RADIOTHERAPY USING IMPLANTED MARKERS [J].
BALTER, JM ;
SANDLER, HM ;
LAM, K ;
BREE, RL ;
LICHTER, AS ;
TENHAKEN, RK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 31 (01) :113-118
[3]   Analysis of prostate and seminal vesicle motion: Implications for treatment planning [J].
Beard, CJ ;
Kijewski, P ;
Bussiere, M ;
Gelman, R ;
Gladstone, D ;
Shaffer, K ;
Plunkett, M ;
Costello, P ;
Coleman, CN .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 34 (02) :451-458
[4]  
COX DR, 1972, J R STAT SOC B, V34, P187
[5]   Hyperfractionated conformal radiotherapy in locally advanced prostate cancer: Results of a dose escalation study [J].
Forman, JD ;
Duclos, M ;
Shamsa, F ;
Porter, AT ;
Orton, C .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 34 (03) :655-662
[6]   NONSTANDARD DEVIATIONS [J].
GOITEIN, M .
MEDICAL PHYSICS, 1983, 10 (05) :709-711
[7]   Conformal technique dose escalation for prostate cancer: Biochemical evidence of improved cancer control with higher doses in patients with pretreatment prostate-specific antigen >=10 ng/ml [J].
Hanks, GE ;
Lee, WR ;
Hanlon, AL ;
Hunt, M ;
Kaplan, E ;
Epstein, BE ;
Movsas, B ;
Schultheiss, TE .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 35 (05) :861-868
[8]   Measurement of patient positioning errors in three-dimensional conformal radiotherapy of the prostate [J].
Hanley, J ;
Lumley, MA ;
Mageras, GS ;
Sun, J ;
Zelefsky, MJ ;
Leibel, SA ;
Fuks, Z ;
Kutcher, GJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 37 (02) :435-444
[9]   Variation in volumes, dose-volume histograms, and estimated normal tissue complication probabilities of rectum and bladder during conformal radiotherapy of T3 prostate cancer [J].
Lebesque, JV ;
Bruce, AM ;
Kroes, APG ;
Touw, A ;
Shouman, T ;
VanHerk, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05) :1109-1119
[10]   Lateral rectal shielding reduces late rectal morbidity following high dose three-dimensional conformal radiation therapy for clinically localized prostate cancer: Further evidence for a significant dose effect [J].
Lee, WR ;
Hanks, GE ;
Hanlon, AL ;
Schultheiss, TE ;
Hunt, MA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 35 (02) :251-257