Characterization of Adrenal Nodules With Dual-Energy CT: Can Virtual Unenhanced Attenuation Values Replace True Unenhanced Attenuation Values?

被引:95
作者
Ho, Lisa M. [1 ]
Marin, Daniele [1 ]
Neville, Amy M. [1 ]
Barnhart, Huiman X. [1 ]
Gupta, Rajan T. [1 ]
Paulson, Erik K. [1 ]
Boll, Daniel T. [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27710 USA
关键词
adrenal nodule characterization; dual-energy CT; virtual unenhanced imaging; NONENHANCED IMAGES; ENHANCED CT; MASSES; ACCURACY; CANCER; PET/CT; PHASE;
D O I
10.2214/AJR.11.7316
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
OBJECTIVE. The purpose of our study was to investigate whether virtual unenhanced adrenal nodule attenuation values can replace true noncontrast attenuation values. MATERIALS AND METHODS. Twenty-three incidentally discovered adrenal nodules (19 adenomas and four metastases) were identified in 19 patients (11 men and eight women; mean age, 65 years; age range, 38-84 years) who underwent unenhanced single-energy CT followed by contrast-enhanced dual-energy CT on the same scanner. A virtual unenhanced imaging dataset was generated from each dual-energy CT dataset. CT attenuation of each adrenal nodule was measured at the same location on virtual unenhanced images and true unenhanced images by three radiologists and mean values compared using the Student t test. Correlation between virtual unenhanced and true unenhanced values was determined using linear regression analysis. The mean difference and percentage of diagnostic agreement were also determined. Interreader variability was assessed using the intraclass correlation coefficient (ICC). RESULTS. The mean +/- SD attenuation values for virtual unenhanced images and true unenhanced images were 14.7 +/- 15.1 HU and 12.9 +/- 13.4 HU, respectively (p = 0.2). Strong positive correlation was observed between virtual unenhanced images and true unenhanced images (R = 0.83-0.87). The mean difference between virtual unenhanced images and true unenhanced images was 1.8 +/- 1.7 HU. Diagnostic agreement between virtual unenhanced images and true unenhanced images was 83-91% for three radiologists. No malignant nodules were misclassified as benign on virtual unenhanced images. The ICC was 0.88 and 0.96 for virtual unenhanced images and true unenhanced images, respectively, indicating high interreader agreement. CONCLUSION. Virtual unenhanced and true unenhanced attenuation measurements of adrenal nodules were not significantly different and showed strongly positive linear correlation. This finding resulted in substantial diagnostic agreement between virtual unenhanced images and true unenhanced images for distinguishing benign from malignant nodules.
引用
收藏
页码:840 / 845
页数:6
相关论文
共 21 条
[11]
Dual energy CT: preliminary observations and potential clinical applications in the abdomen [J].
Graser, Anno ;
Johnson, Thorsten R. C. ;
Chandarana, Hersh ;
Macari, Michael .
EUROPEAN RADIOLOGY, 2009, 19 (01) :13-23
[12]
Dual-Energy CT for Characterization of Adrenal Nodules: Initial Experience [J].
Gupta, Rajan T. ;
Ho, Lisa M. ;
Marin, Daniele ;
Boll, Daniel T. ;
Barnhart, Huiman X. ;
Nelson, Rendon C. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (06) :1479-1483
[13]
HEDELAND H, 1968, ACTA MED SCAND, V184, P211
[14]
Comparison of CT histogram analysis and chemical shift MRI in the characterization of indeterminate adrenal nodules [J].
Jhaveri, Kartik S. ;
Wong, Fenella ;
Ghai, Sangeet ;
Haider, Masoom A. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 187 (05) :1303-1308
[15]
Effect of Organ Enhancement and Habitus on Estimation of Unenhanced Attenuation at Contrast-Enhanced Dual-Energy MDCT: Concepts for Individualized and Organ-Specific Spectral Iodine Subtraction Strategies [J].
Miller, Chad M. ;
Gupta, Rajan T. ;
Paulson, Erik K. ;
Neville, Amy M. ;
Bashir, Mustafa R. ;
Merkle, Elmar M. ;
Boll, Daniel T. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (05) :W558-W564
[16]
Detection of Renal Lesion Enhancement with Dual-Energy Multidetector CT [J].
Neville, Amy M. ;
Gupta, Rajan T. ;
Miller, Chad M. ;
Merkle, Elmar M. ;
Paulson, Erik K. ;
Boll, Daniel T. .
RADIOLOGY, 2011, 259 (01) :173-183
[17]
Adrenal masses: Correlation between CT attenuation value and chemical shift ratio at MR imaging with in-phase and opposed-phase sequences [J].
Outwater, EK ;
Siegelman, ES ;
Huang, AB ;
Birnbaum, BA .
RADIOLOGY, 1996, 200 (03) :749-752
[18]
Technical principles of dual source CT [J].
Petersilka, Martin ;
Bruder, Herbert ;
Krauss, Bernhard ;
Stierstorfer, Karl ;
Flohr, Thomas G. .
EUROPEAN JOURNAL OF RADIOLOGY, 2008, 68 (03) :362-368
[19]
Incidental Adrenal Lesions: Accuracy of Characterization with Contrast-enhanced Washout Multidetector CT-10-minute Delayed Imaging Protocol Revisited in a Large Patient Cohort [J].
Sangwaiya, Minal J. ;
Boland, Giles W. L. ;
Cronin, Carmel G. ;
Blake, Michael A. ;
Halpern, Elkan F. ;
Hahn, Peter F. .
RADIOLOGY, 2010, 256 (02) :504-510
[20]
Detectability of Urinary Stones on Virtual Nonenhanced Images Generated at Pyelographic-Phase Dual-Energy CT [J].
Takahashi, Naoki ;
Vrtiska, Terri J. ;
Kawashima, Akira ;
Hartman, Robert P. ;
Primak, Andrew N. ;
Fletcher, Joel G. ;
McCollough, Cynthia H. .
RADIOLOGY, 2010, 256 (01) :184-190