Reversed-phase porous silica rods, an alternative approach to high-performance liquid chromatographic separation using the sequential injection chromatography technique

被引:52
作者
Satinsky, D [1 ]
Huclová, J [1 ]
Solich, P [1 ]
Karlicek, R [1 ]
机构
[1] Charles Univ, Fac Pharm, Dept Analyt Chem, Res Ctr LN00B125, Hradec Kralove 50005, Czech Republic
关键词
sequential injection analysis; sequential injection chromatography; monolithic columns; injection methods; instrumentation; parabens; pesticides; triamcinolone acetonide;
D O I
10.1016/S0021-9673(03)01239-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A commercially available porous silica rod column was used as a separation tool for the sequential injection analysis (SIA). A porous solid monolithic column showed high performance at a low pressure, allowing sequential injection analysis to be used for the first time for separation in HPLC fashion. In this contribution, we tried to demonstrate a new separation concept with SIA manifold for the simultaneous determination of four different compounds (methylparaben (MP), propylparaben (PP), triamcinolone acetonide (TCA) and internal standard ketoprofen (KP)) in a pharmaceutical triamcinolon cream 0.1% formulation. A Chromolith Flash RP-18e, 25 mm x 4.6 mm column with a 10 mm pre-column (Merck, Germany) and a FIAlab 3000 system (USA) with an 8-port selection valve and 10 ml syringe were used for sequential injection chromatographic separations in our study. The mobile phase used was acetonitrile-methanol-water (35:5:65, v/v/v) + 0.05% nonylamine, pH 2.5, flow rate 0.6 ml min(-1). The analysis time was <6 min. A novel sequential injection chromatography (SIC) technique with UV spectrophotometric detection was optimised and validated. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:239 / 244
页数:6
相关论文
共 15 条
[1]   On-line post-column photochemical derivatization in liquid chromatographic-diode-array detection analysis of binary drug mixtures [J].
DiPietra, AM ;
Andrisano, V ;
Gotti, R ;
Cavrini, V .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1996, 14 (8-10) :1191-1199
[2]  
Guebeli T, 1991, ANAL CHEM, V63, P2407
[3]   Determination of indinavir, potassium sorbate, methylparaben, and propylparaben in aqueous pediatric suspensions [J].
Kreuz, DM ;
Howard, AL ;
Ip, D .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 19 (05) :725-735
[4]   Octadecylsilylated porous silica rods as separation media for reversed-phase liquid chromatography [J].
Minakuchi, H ;
Nakanishi, K ;
Soga, N ;
Ishizuka, N ;
Tanaka, N .
ANALYTICAL CHEMISTRY, 1996, 68 (19) :3498-3501
[5]   Effect of domain size on the performance of octadecylsilylated continuous porous silica columns in reversed-phase liquid chromatography [J].
Minakuchi, H ;
Nakanishi, K ;
Soga, N ;
Ishizuka, N ;
Tanaka, N .
JOURNAL OF CHROMATOGRAPHY A, 1998, 797 (1-2) :121-131
[6]   Effect of skeleton size on the performance of octadecylsilylated continuous porous silica columns in reversed-phase liquid chromatography [J].
Minakuchi, H ;
Nakanishi, K ;
Soga, N ;
Ishizuka, N ;
Tanaka, N .
JOURNAL OF CHROMATOGRAPHY A, 1997, 762 (1-2) :135-146
[7]   Molded rigid polymer monoliths as separation media for capillary electrochromatography [J].
Peters, EC ;
Petro, M ;
Svec, F ;
Frechet, JMJ .
ANALYTICAL CHEMISTRY, 1997, 69 (17) :3646-3649
[8]   Development in release testing of topical dosage forms:: use of the Enhancer Cell™ with automated sampling [J].
Rege, PR ;
Vilivalam, VD ;
Collins, CC .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 17 (08) :1225-1233
[9]   PRINCIPLES OF STOPPED-FLOW SEQUENTIAL INJECTION-ANALYSIS AND ITS APPLICATION TO THE KINETIC DETERMINATION OF TRACES OF A PROTEOLYTIC-ENZYME [J].
RUZICKA, J ;
GUBELI, T .
ANALYTICAL CHEMISTRY, 1991, 63 (17) :1680-1685
[10]   VARIABLE FLOW-RATES AND A SINUSOIDAL FLOW PUMP FOR FLOW-INJECTION ANALYSIS [J].
RUZICKA, J ;
MARSHALL, GD ;
CHRISTIAN, GD .
ANALYTICAL CHEMISTRY, 1990, 62 (17) :1861-1866