The Array silicone multifocal IOL: Experiences after 150 implantations

被引:11
作者
Eisenmann, D
Jacobi, FK
Dick, B
Jacobi, KW
机构
关键词
Array multifocal IOL; monofocal IOL; pseudoaccommodation; contrast acuity; contrast sensitivity;
D O I
10.1055/s-2008-1035211
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background The Array-MIOL offers the advantage of an increased depth of focus; the aim of our study was to compare other functional results with those of a monofocal IOL. Methods Uncorrected and corrected distance and near visual acuity were measured in the early postoperative period and after 3 months. Results of contrast acuity (Regan charts) and contrast sensitivity (BVAT II-SG video acuity tester) of the Array-MIOL and a monofocal IOL were compared at the 3-months follow-up. Results Distance visual acuity of the multifocal group did not differ from the monofocal results; uncorrected and distance corrected near acuity were significantly superior in Array patients. The monofocal IOL showed a superior contrast acuity only at the 11% level and a superior contrast sensitivity only at one spatial frequency (20 cpd). Bilateral implantation of the Array-MIOL seems to further improve functional results. Conclusion Implantation of the Array silicone multifocal IOL offers the advantage of pseudoaccommodation without relevant impairment of other visual functions.
引用
收藏
页码:270 / 272
页数:3
相关论文
共 15 条
[1]   CONTRAST SENSITIVITY AND READING THROUGH MULTIFOCAL INTRAOCULAR LENSES [J].
AKUTSU, H ;
LEGGE, GE ;
SHOWALTER, M ;
LINDSTROM, RL ;
ZABEL, RW ;
KIRBY, VM .
ARCHIVES OF OPHTHALMOLOGY, 1992, 110 (08) :1076-1080
[2]  
CORVIN TR, 1989, OPTOMETRY VIS SCI, V66, P864
[3]  
DUFFEY RJ, 1889, J CATARACT REFR SURG, V16, P423
[4]   THE ARRAY MULTIFOCAL IOL - CONCEPT AND CLINICAL-RESULTS [J].
EISENMANN, D ;
JACOBI, KW .
KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1993, 203 (03) :189-194
[5]  
EISENMANN D, 1993, EUR J IMPLANT REFRAC, V5, P99
[6]   MULTIFOCAL VERSUS MONOFOCAL INTRAOCULAR LENSES VISUAL AND REFRACTIVE COMPARISONS [J].
ELMAGHRABY, A ;
MARZOUKY, A ;
GAZAYERLI, E ;
VANDERKARR, M ;
DELUCA, M .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1992, 18 (02) :147-152
[7]   MULTIFOCAL INTRAOCULAR LENSES - STATE-OF-THE-ART [J].
HESSEMER, V ;
EISENMANN, D ;
JACOBI, KW .
KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1993, 203 (01) :19-33
[8]   OPTICAL-PERFORMANCE OF MULTIFOCAL INTRAOCULAR LENSES [J].
HOLLADAY, JT ;
VANDIJK, H ;
LANG, A ;
PORTNEY, V ;
WILLIS, TR ;
SUN, R ;
OKSMAN, HC .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1990, 16 (04) :413-422
[9]   CONTRAST SENSITIVITY IN PATIENTS WITH A NEW TYPE OF MULTIFOCAL INTRAOCULAR-LENS [J].
OLSEN, T ;
CORYDON, L .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1990, 16 (01) :42-46
[10]  
REGAN D, 1983, OPHTHALMOLOGY, V90, P1192