Secondary neutrons in clinical proton radiotherapy: A charged issue

被引:133
作者
Brenner, David J. [1 ]
Hatt, Eric J. [1 ]
机构
[1] Columbia Univ, Med Ctr, Ctr Radiol Res, New York, NY 10032 USA
关键词
proton radiotherapy; secondary neutrons; second cancers; passive scattering;
D O I
10.1016/j.radonc.2007.12.003
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Hospital-based proton facilities may represent a major advance in radiation therapy, in part because of excellent dose distributions around the tumor, and in part because of the potentially lower whole-body dose compared with photon radiotherapy. Most current proton beams are spread out to cover the tumor using beam scattering and collimation techniques (passive scattering); this will necessarily result in an extra whole-body neutron dose, due to interactions of the protons with the scattering and collimating beam elements. However, the clinical significance of this whole-body low-dose neutron exposure has remained controversial. The number of proton facilities worldwide is increasing rapidly, and most of these facilities are/will be based on passive scattering. Thus it is important to assess and, ideally, minimize, the potential for second cancer induction by secondary neutrons. We discuss here the neutron doses involved, and the associated potential second cancer risks, with an emphasis on the uncertainties involved. (c) 2007 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:165 / 170
页数:6
相关论文
共 67 条
[1]   Secondary neutron and photon dose in proton therapy [J].
Agosteo, S ;
Birattari, C ;
Caravaggio, M ;
Silari, M ;
Tosi, G .
RADIOTHERAPY AND ONCOLOGY, 1998, 48 (03) :293-305
[2]   Monte Carlo simulation estimates of neutron doses to critical organs of a patient undergoing 18 MV x-ray LINAC-based radiotherapy [J].
Barquero, R ;
Edwards, TM ;
Iñiguez, MP ;
Vega-Carrillo, HR .
MEDICAL PHYSICS, 2005, 32 (12) :3579-3588
[3]   Secondary dose exposures during 200 MeV proton therapy [J].
Binns, PJ ;
Hough, JH .
RADIATION PROTECTION DOSIMETRY, 1997, 70 (1-4) :441-444
[4]   Therapeutic step and shoot proton beam spot-scanning with a multi-leaf collimator: A Monte Carlo study [J].
Bues, M ;
Newhauser, WD ;
Titt, U ;
Smith, AR .
RADIATION PROTECTION DOSIMETRY, 2005, 115 (1-4) :164-169
[5]   Significant reduction of normal tissue dose by proton radiotherapy compared with three-dimensional conformal or intensity-modulated radiation therapy in Stage I or Stage III non-small-cell lung cancer [J].
Chang, Joe Y. ;
Zhang, Xiaodong ;
Wang, Xiaochun ;
Kang, Yixiu ;
Riley, Beverly ;
Bilton, Stephen ;
Mohan, Radhe ;
Komaki, Ritsuko ;
Cox, James D. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (04) :1087-1096
[6]   The assessment of RBE effects using the concept of biologically effective dose [J].
Dale, RG ;
Jones, B .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 43 (03) :639-645
[7]   DS02 fluence spectra for neutrons and gamma rays at Hiroshima and Nagasaki with fluence-to-kerma coefficients and transmission factors for sample measurements [J].
Egbert, Stephen D. ;
Kerr, George D. ;
Cullings, Harry M. .
RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2007, 46 (04) :311-325
[8]  
FERRARI P, IN PRESS RAD PROT DO
[9]   Design tools for proton therapy nozzles based on the double-scattering foil technique [J].
Fontenot, JD ;
Newhauser, WD ;
Titt, U .
RADIATION PROTECTION DOSIMETRY, 2005, 116 (1-4) :211-215
[10]  
GOTTSCHALK B, 2006, INT J RADIAT ONCOL, V65, P1