Transvaginal color Doppler assessment of venous flow in adnexal masses

被引:7
作者
Alcázar, JL [1 ]
López-García, G [1 ]
机构
[1] Univ Navarra, Univ Navarra Clin, Sch Med, Dept Obstet & Gynecol, Pamplona 31008, Spain
关键词
adnexal mass; Doppler ultrasound; arterial flow; venous flow;
D O I
10.1046/j.1469-0705.2001.00394.x
中图分类号
O42 [声学];
学科分类号
070206 [声学]; 082403 [水声工程];
摘要
Objective To analyze the usefulness of transvaginal color Doppler assessment of venous flow in the differential diagnosis of adnexal masses. Material and Methods Ninety-one consecutive patients (mean age: 46.6 years, range: 16-81 years) diagnosed as having an adnexal mass were evaluated by transvaginal color Doppler sonography prior to surgery. Color Doppler was used to detect and analyze the flow velocity waveform from arterial and venous blood flow within the tumor. For arterial signals the resistance inner and peak systolic velocity and for veins the maximum venous flow velocity, were calculated. Receiver operator characteristic corves were plotted to determine the best venous flow velocity cut-off. According to our previous study using arterial Doppler, a tumor was considered as malignant when flow wits detected and the lowest resistance index was less than or equal to 0.45. Using venous Doppler a mass was considered as malignant when flow was detected and the venous flow velocity was greater than or equal to the best cut-off found on the receiver operator characteristic curve. Definitive histopathological diagnosis was obtained in all cases. Sensitivity, specificity, positive predictive value and negative predictive value for B-mode morphology (evaluation performed according to Sassone's scoring system), arterial Doppler, venous Doppler, and a combination of both arterial and venous Doppler were calculated. Results Twenty-five masses (27.5%) were malignant and 66 (72.5%) benign. Arterial and venous flow was found more frequently in malignant than in benign masses (92% vs. 41% (P < 0.001) and 72% vs. 21% (P < 0.001), respectively). The resistance index was significantly lower in malignant tumors (0.42 vs. 0.60, P = 0.0003). No differences were found in peak systolic velocity. Venous flow velocity was significantly higher in malignant masses (18.1 cm/s vs. 8.9 cm/s, P = 0.0006). The best cut-off of venous pou, velocity was 10 cm/s. Sensitivity, specificity, positive predictive value and negative predictive value for morphology, arterial Doppler, venous Doppler, and the combination of both arterial and venous Doppler were 92%, 71%, 45%, 96%; 76%, 95%, 87%, 91%; 68%, 94%, 81%, 89%; and 88%, 91%, 79%, 95%, respectively. Conclusions Our results indicate that preoperative evaluation by venous flow assessment of adnexal masses may be useful to discriminate between malignant and benign tumors.
引用
收藏
页码:434 / 438
页数:5
相关论文
共 30 条
[1]
Transvaginal color Doppler sonography in adnexal masses: Which parameter performs best [J].
Alcazar, JL ;
RuizPerez, ML ;
Errasti, T .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1996, 8 (02) :114-119
[2]
Using a logistic model to predict malignancy of adnexal masses based on menopausal status, ultrasound morphology, and color Doppler findings [J].
Alcazar, JL ;
Jurado, M .
GYNECOLOGIC ONCOLOGY, 1998, 69 (02) :146-150
[3]
In vivo validation of the time domain velocity measurement technique of blood flow in human fetuses [J].
Alcazar, JL ;
Laparte, C .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (01) :9-13
[4]
BROMLEY B, 1994, OBSTET GYNECOL, V83, P434
[5]
TUMOR VASCULARIZATION - ASSESSMENT WITH DUPLEX SONOGRAPHY [J].
DOCK, W ;
GRABENWOGER, F ;
METZ, V ;
EIBENBERGER, K ;
FARRES, MT .
RADIOLOGY, 1991, 181 (01) :241-244
[6]
FLEISCHER AC, 1993, J ULTRAS MED, V12, P41
[7]
ANGIOGENESIS IN CANCER, VASCULAR, RHEUMATOID AND OTHER DISEASE [J].
FOLKMAN, J .
NATURE MEDICINE, 1995, 1 (01) :27-31
[8]
TRANSVAGINAL COLOR DOPPLER SONOGRAPHY OF ADNEXAL MASSES - DIFFERENCES IN BLOOD-FLOW IMPEDANCE IN BENIGN AND MALIGNANT LESIONS [J].
HAMPER, UM ;
SHETH, S ;
ABBAS, FM ;
ROSENSHEIN, NB ;
ARONSON, D ;
KURMAN, RJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (06) :1225-1228
[9]
HATA K, 1992, OBSTET GYNECOL, V80, P922
[10]
DIFFERENTIAL-DIAGNOSIS OF OVARIAN-TUMORS BY TRANSVAGINAL COLOR-PULSE DOPPLER SONOGRAPHY [J].
KAWAI, M ;
KIKKAWA, F ;
ISHIKAWA, H ;
TAMAKOSHI, K ;
MAEDA, O ;
HASEGAWA, N ;
MIZUNO, K ;
SUZUKI, A ;
ITAKURA, A ;
NAKASHIMA, N ;
TOMODA, Y .
GYNECOLOGIC ONCOLOGY, 1994, 54 (02) :209-214