40 MHz Doppler characterization of umbilical and dorsal aortic blood flow in the early mouse embryo

被引:81
作者
Phoon, CKL
Aristizabal, O
Turnbull, DH
机构
[1] NYU, Sch Med, Pediat Cardiol Program, New York, NY 10016 USA
[2] NYU, Sch Med, Inst Biomol Med, New York, NY 10016 USA
[3] NYU, Sch Med, Dept Radiol, New York, NY 10016 USA
[4] NYU, Sch Med, Dept Pathol, New York, NY 10016 USA
关键词
cardiovascular development; Doppler; echocardiography; hemodynamics; imaging; morphogenesis; physiology;
D O I
10.1016/S0301-5629(00)00278-7
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Physiological study of the developing mouse circulation has lagged behind advances in molecular cardiology. Using an innovative high-frequency Doppler system, we noninvasively characterized circulatory hemodynamics in early mouse embryos. We used image-guided 43 MHz pulsed-wave (PW) Doppler ultrasound to study the umbilical artery and vein, or dorsal aorta in 109 embryos. Studies were conducted on embryonic days (E) 9.5-14.5. Heart rate, peak blood flow velocities, and velocity time integrals in all vessels increased from E9.5-14.5, indicating increasing stroke volume and cardiac output. Heart rate, ranging from 192 bpm (E9.5) to 261 bpm (E14.5), was higher than previously reported. Placental impedance, assessed by the time delay between the peaks of the umbilical arterial and venous waveforms and by venous pulsatility, decreased with gestation. Acceleration time, a load-independent Doppler index of cardiac contractility, remained constant but seemed sensitive to heart rate. High-frequency PW Doppler is a powerful tool for the quantitative, noninvasive investigation of early mouse circulatory development. (C) 2000 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:1275 / 1283
页数:9
相关论文
共 27 条
[1]   40-MHz echocardiography scanner for cardiovascular assessment of mouse embryos [J].
Aristizábal, O ;
Christopher, DA ;
Foster, FS ;
Turnbull, DH .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (09) :1407-1417
[2]  
BERNSTEIN SELDON E., 1966, P337
[3]   HEMODYNAMIC PARAMETERS OF STAGE-20 TO STAGE-35 CHICK-EMBRYO [J].
BROEKHUIZEN, MLA ;
MAST, F ;
STRUIJK, PC ;
VANDERBIE, W ;
MULDER, PGH ;
GITTENBERGERDEGROOT, AC ;
WLADIMIROFF, JW .
PEDIATRIC RESEARCH, 1993, 34 (01) :44-46
[4]   A high-frequency pulsed-wave doppler ultrasound system for the detection and imaging of blood flow in the microcirculation [J].
Christopher, DA ;
Burns, PN ;
Starkoski, BG ;
Foster, FS .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (07) :997-1015
[5]   HEMODYNAMICS OF THE DEVELOPING CARDIOVASCULAR-SYSTEM [J].
CLARK, EB ;
HU, N .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1990, 588 :41-47
[6]   IMPLANTATION AND THE PLACENTA - KEY PIECES OF THE DEVELOPMENT PUZZLE [J].
CROSS, JC ;
WERB, Z ;
FISHER, SJ .
SCIENCE, 1994, 266 (5190) :1508-1518
[7]  
DURSTZIVKOVIC B, 1978, EXPERIENTIA, V34, P1343
[8]   Neonatal cardiomyopathy in mice homozygous for the Arg403Gln mutation in the α cardiac myosin heavy chain gene [J].
Fatkin, D ;
Christe, ME ;
Aristizabal, O ;
McConnell, BK ;
Srinivasan, S ;
Schoen, FJ ;
Seidman, CE ;
Turnbull, DH ;
Seidman, JG .
JOURNAL OF CLINICAL INVESTIGATION, 1999, 103 (01) :147-153
[9]  
FLECKNELL PA, 1993, METHOD ENZYMOL, V225, P16