A randomized, prospective evaluation of the Tesio, Ash split, and Opti-flow hemodialysis catheters

被引:41
作者
Richard, HM [1 ]
Hastings, GS [1 ]
Boyd-Kranis, RL [1 ]
Murthy, R [1 ]
Radack, DM [1 ]
Santilli, JG [1 ]
Ostergaard, C [1 ]
Coldwell, DM [1 ]
机构
[1] Univ Maryland, Med Syst, Dept Diagnost Imaging, Div Intervent Radiol, Baltimore, MD 21201 USA
关键词
catheters and catheterization technology; dialysis;
D O I
10.1016/S1051-0443(07)61880-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: A randomized, prospective evaluation of three high-flow hemodialysis catheters. MATERIALS AND METHODS: Ninety-four patients were randomly assigned 113 Tesio, Ash split, and Opti-flow catheters from December 1998 through Tune 1999. Insertion times, procedural complications, and ease of insertion were recorded. Mean catheter flow rates were recorded at first dialysis, 30 days, and 90 days. Patency, catheter survival, and catheter-related infections were evaluated. RESULTS: Thirty-eight Ash split, 39 Opti-flow, and 36 Tesio catheters were placed. Tesio mean insertion time (41.5 min) was significantly longer than Ash split (29.4 min) or Opti-flow (29.6 min) (P =.004). There were four complications related to Tesio catheters (three cases of pericatheter bleeding, one air embolism), one related to an Opti-flow catheter (pericatheter bleeding), and zero related to Ash split catheters. Opti-flow and Ash split catheters were significantly easier to insert than Tesio catheters (P =.041). Mean flow rates were not significantly different among the catheters initially (P =.112), at 30 days (P =.281), or at 90 days (P =.112). Catheter-related infection rates per 100 catheter days were 0.12 for Ash split, 0.35 for Opti-flow, and 0.14 for Tesio. Median catheter survival was 302 days for Ash split, 176 days for Opti-flow, and 228 days for Tesio. CONCLUSIONS: Opti-Flow and Ash split catheters were faster and easier to place than Tesio catheters. There was no difference in hemodialysis flow rates or catheter survival.
引用
收藏
页码:431 / 435
页数:5
相关论文
共 12 条
[1]   INTERNAL JUGULAR-VEIN CANNULATION WITH 2 SILICONE-RUBBER CATHETERS - A NEW AND SAFE TEMPORARY VASCULAR ACCESS FOR HEMODIALYSIS - 30 MONTHS EXPERIENCE [J].
CANAUD, B ;
BERAUD, JJ ;
JOYEUX, H ;
MION, C .
ARTIFICIAL ORGANS, 1986, 10 (05) :397-403
[2]   Outcome of tunneled hemodialysis catheters placed by radiologists [J].
Lund, GB ;
Trerotola, SO ;
Scheel, PF ;
Savader, SJ ;
Mitchell, SE ;
Venbrux, AC ;
Osterman, FA .
RADIOLOGY, 1996, 198 (02) :467-472
[3]   Comparison of blood flow rates and hydraulic resistance between the Mahurkar catheter, the Tesio twin catheter, and the Ash Split Cath [J].
Mankus, RA ;
Ash, SR ;
Sutton, JM .
ASAIO JOURNAL, 1998, 44 (05) :M532-M534
[4]   Translumbar inferior vena caval Tesio catheter for hemodialysis [J].
Markowitz, DG ;
Rosenblum, DI ;
Newman, JS ;
Garby, KB .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1998, 9 (01) :145-147
[5]  
MCDONALD DE, 1993, AM SURGEON, V9, P569
[6]   Long-term performance and complications of the Tesio twin catheter system for hemodialysis access [J].
Prabhu, PN ;
Kerns, SR ;
Sabatelli, FW ;
Hawkins, IF ;
Ross, EA .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1997, 30 (02) :213-218
[7]   Image-guided insertion of the Uldall tunneled hemodialysis catheter: Technical success and clinical follow-up [J].
Schnabel, KJ ;
Simons, ME ;
Zevallos, GF ;
Pron, GE ;
Fenton, SSA ;
Sniderman, KW ;
Vanderburgh, LC .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1997, 8 (04) :579-586
[8]  
Schwab S, 1997, AM J KIDNEY DIS, V30, pS150
[9]   The hemodialysis catheter conundrum: Hate living with them, but can't live without them [J].
Schwab, SJ ;
Beathard, G .
KIDNEY INTERNATIONAL, 1999, 56 (01) :1-17
[10]   DOUBLE CATHETERIZATION OF THE INTERNAL JUGULAR-VEIN FOR HEMODIALYSIS - INDICATIONS, TECHNIQUES, AND CLINICAL-RESULTS [J].
TESIO, F ;
DEBAZ, H ;
PANARELLO, G ;
CALIANNO, G ;
QUAIA, P ;
RAIMONDI, A ;
SCHINELLA, D .
ARTIFICIAL ORGANS, 1994, 18 (04) :301-304